Refrigerated compressed air driers typically run ____% of the time .

(Multiple Choice)
4.8/5
(44)

In a kitchen, ____ condensing units may be easier to maintain.

(Multiple Choice)
4.7/5
(48)

The precharged tubing for refrigeration piping is ____________________ at both ends and has quick connect fittings .

(Short Answer)
4.8/5
(39)

The primary advantage of parallel compressor systems is their ____.

(Multiple Choice)
4.9/5
(35)

Carbon dioxide (CO2) is one of the newest refrigerants .

(True/False)
4.9/5
(34)

At its triple point, CO2 can exist as ____ .

(Multiple Choice)
4.8/5
(41)

How are the normal condenser and the heat reclaim condenser used when in the heat reclaim mode in a series heat reclaim system ?

(Essay)
4.9/5
(35)

Explain what pilot operation means.

(Essay)
4.9/5
(43)

Distributed supermarket refrigeration modules that are located very close to the display cases they refrigerate are becoming increasingly popular .

(True/False)
4.9/5
(29)

The heat reclaim valve is a three-way valve that is activated by a solenoid operated by a ____ .

(Multiple Choice)
5.0/5
(35)
Match each term with the correct statement below.
When air is used for controls
bleed ports
Usually installed in the heat reclaim pump-out or bleed line to prevent migration of refrigerant to the coldest location
check valve
Tremendous forces that can cause refrigerant lines and values to rupture
liquid hammer
Correct Answer:
Verified
Premises:
Responses:
When air is used for controls
bleed ports
Usually installed in the heat reclaim pump-out or bleed line to prevent migration of refrigerant to the coldest location
check valve
Tremendous forces that can cause refrigerant lines and values to rupture
liquid hammer
Applies a false load on the evaporator when there is no load
pneumatic control
Removes refrigerant from the heat reclaim coil when it is not being used
hot gas bypass valve
(Matching)
4.7/5
(45)

Often, parallel compressor systems employ a satellite or booster compressor .

(True/False)
4.9/5
(48)

____________________ are basically refrigeration systems located in the air supply, after the storage tank.

(Short Answer)
4.9/5
(35)

CO2, ammonia, propane, butane, and isobutane are all natural refrigerants .

(True/False)
4.8/5
(36)
Showing 21 - 34 of 34
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)