Deck 26: Process Auxiliaries

Full screen (f)
exit full mode
Question
Which of the following improper operation would most likely lead to potential fire or explosion?

A) Refrigerant leak
B) Regenerator temperature too low
C) Amine temperature in contactor too high
D) Loss of lubrication on equipment
Use Space or
up arrow
down arrow
to flip the card.
Question
What is the name of the vessel where the rich amine is dropped lower in pressure and then heated?

A) Contactor
B) Absorber
C) Fluidizer
D) Regenerator
Question
What component of mechanical refrigeration systems is a heat exchanger that uses the refrigerant to remove heat and, in the process, the refrigerant evaporates?

A) Receiver
B) Compressor
C) Evaporator
D) Condenser
Question
What type of refrigeration system use a refrigerant for cooling?

A) Absorption
B) Functional
C) Mechanical
D) Evaporation
Question
What is the pipe system that connects process unit vents to the flare?

A) Flare stack
B) Flare header
C) Knockout drum
D) Steam ring
Question
When are flare systems heavily used?

A) During plant decommissioning procedures
B) During startup of equipment
C) During cleaning of equipment
D) All of the above
Question
Which component of a hot oil system moves oil through the circulation and heating systems?

A) Storage tank
B) Oil pump
C) Oil circulation system
D) Oil heating system
Question
Which of the following is a maintenance activity for refrigeration systems?

A) Check the expansion valve
B) Check pilot gas regulator for proper flow
C) Check that the pilot is lit
D) Check purge gas for proper flow
Question
Which of the following improper operation is least likely cause exposure to toxic fumes?

A) Flare pilot or burner not lit
B) Failure to line up purge gas to flare stack
C) Refrigerant leak
D) Loss of lubrication on equipment
Question
Which method of supplying lubricants to equipment uses handheld devices?

A) Grease guns
B) Hot oil system
C) Glass bottle oiler cup
D) Automatic grease lubricator
Question
Which component of lubrication systems is a device that removes contaminants and particulates from the lubricant prior to circulation through a system?

A) Cooler
B) Filter
C) Pump
D) Lube oil reservoir tank
Question
What is a common use of an amine system?

A) To remove chemicals from water
B) To remove wastewater from a plant
C) To remove CO2 from a synthesized gas stream
D) To burn unwanted gases before they are released into the atmosphere
Question
What is used to burn off flammable excess (or waste) substances?

A) Incinerator
B) Flare system
C) Hot oil system
D) Evaporator
Question
Which component of a hot oil system is a heater or furnace that raises the temperature of the oil to the desired temperature?

A) Storage tank
B) Oil pump
C) Oil circulation system
D) Oil heating system
Question
What component of mechanical refrigeration systems is a device used to increase the pressure of a refrigerant in the gas phase?

A) Receiver
B) Compressor
C) Evaporator
D) Condenser
Question
Which of the following is a common lubricant?

A) Water
B) Grease
C) Steam
D) Natural gas
Question
What system uses motive gas to make a solid particulate substance flow like a liquid?

A) Hot oil system
B) Fluidized bed system
C) Nitrogen header system
D) Flare system
Question
Which of the following is the most common auxiliary system?

A) Flare system
B) Amine system
C) Fluidized bed system
D) Nitrogen header system
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/18
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 26: Process Auxiliaries
1
Which of the following improper operation would most likely lead to potential fire or explosion?

A) Refrigerant leak
B) Regenerator temperature too low
C) Amine temperature in contactor too high
D) Loss of lubrication on equipment
A
Explanation: A) Correct. Refrigerant leak can lead to potential fire or explosion.
B) Incorrect. Regenerator temperature too low would not lead to potential fire or explosion.
C) Incorrect. Contactor temperature too high would not lead to potential fire or explosion.
D) Incorrect. Loss of lubrication on equipment would not lead to potential fire or explosion.
2
What is the name of the vessel where the rich amine is dropped lower in pressure and then heated?

A) Contactor
B) Absorber
C) Fluidizer
D) Regenerator
D
Explanation: A) Incorrect. The vessel where the rich amine is dropped lower in pressure and then heated is commonly called the stripper or regenerator.
B) Incorrect. The vessel where the rich amine is dropped lower in pressure and then heated is commonly called the stripper or regenerator.
C) Incorrect. The vessel where the rich amine is dropped lower in pressure and then heated is commonly called the stripper or regenerator.
D) Correct. The vessel where the rich amine is dropped lower in pressure and then heated is commonly called the stripper or regenerator.
3
What component of mechanical refrigeration systems is a heat exchanger that uses the refrigerant to remove heat and, in the process, the refrigerant evaporates?

A) Receiver
B) Compressor
C) Evaporator
D) Condenser
C
Explanation: A) Incorrect. A receiver is a tank that stores the liquid phase refrigerant once it leaves the condenser.
B) Incorrect. A compressor is a device used to increase the pressure of a refrigerant in the gas phase.
C) Correct. An evaporator is a heat exchanger that uses the refrigerant to remove heat and, in the process, the refrigerant evaporates.
D) Incorrect. A condenser is a device used to cool the gas phase refrigerant from the compressor so that it condenses back into a liquid phase.
4
What type of refrigeration system use a refrigerant for cooling?

A) Absorption
B) Functional
C) Mechanical
D) Evaporation
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
5
What is the pipe system that connects process unit vents to the flare?

A) Flare stack
B) Flare header
C) Knockout drum
D) Steam ring
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
6
When are flare systems heavily used?

A) During plant decommissioning procedures
B) During startup of equipment
C) During cleaning of equipment
D) All of the above
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
7
Which component of a hot oil system moves oil through the circulation and heating systems?

A) Storage tank
B) Oil pump
C) Oil circulation system
D) Oil heating system
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
8
Which of the following is a maintenance activity for refrigeration systems?

A) Check the expansion valve
B) Check pilot gas regulator for proper flow
C) Check that the pilot is lit
D) Check purge gas for proper flow
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
9
Which of the following improper operation is least likely cause exposure to toxic fumes?

A) Flare pilot or burner not lit
B) Failure to line up purge gas to flare stack
C) Refrigerant leak
D) Loss of lubrication on equipment
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
10
Which method of supplying lubricants to equipment uses handheld devices?

A) Grease guns
B) Hot oil system
C) Glass bottle oiler cup
D) Automatic grease lubricator
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
11
Which component of lubrication systems is a device that removes contaminants and particulates from the lubricant prior to circulation through a system?

A) Cooler
B) Filter
C) Pump
D) Lube oil reservoir tank
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
12
What is a common use of an amine system?

A) To remove chemicals from water
B) To remove wastewater from a plant
C) To remove CO2 from a synthesized gas stream
D) To burn unwanted gases before they are released into the atmosphere
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
13
What is used to burn off flammable excess (or waste) substances?

A) Incinerator
B) Flare system
C) Hot oil system
D) Evaporator
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
14
Which component of a hot oil system is a heater or furnace that raises the temperature of the oil to the desired temperature?

A) Storage tank
B) Oil pump
C) Oil circulation system
D) Oil heating system
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
15
What component of mechanical refrigeration systems is a device used to increase the pressure of a refrigerant in the gas phase?

A) Receiver
B) Compressor
C) Evaporator
D) Condenser
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
16
Which of the following is a common lubricant?

A) Water
B) Grease
C) Steam
D) Natural gas
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
17
What system uses motive gas to make a solid particulate substance flow like a liquid?

A) Hot oil system
B) Fluidized bed system
C) Nitrogen header system
D) Flare system
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
18
Which of the following is the most common auxiliary system?

A) Flare system
B) Amine system
C) Fluidized bed system
D) Nitrogen header system
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 18 flashcards in this deck.