Deck 10: Decontamination, Sterilization, and Disinfection

Full screen (f)
exit full mode
Question
Which class includes indicators that respond to only one critical parameter with an exact value?

A) 2
B) 5
C) 1
D) 3
Use Space or
up arrow
down arrow
to flip the card.
Question
There are three distinct phases in all types of steam sterilizers. __________ is when air is removed from the chamber and replaced with steam.

A) Conditioning
B) Exposure
C) Parameter
D) Indication
Question
The ultrasonic cleaner removes debris from instruments by a process called __________.

A) cavitation
B) agitation
C) osculation
D) both A and B
Question
Which class includes indicators that are the most exacting and accurate of all indicators and that react to all critical values over a specified range in the sterilization process?

A) 5
B) 4
C) 3
D) 2
Question
A _________________ is a paper strip or specially treated tape that changes color when exposed to a specific temperature.

A) wrapping paper
B) litmus paper
C) paper monitor
D) chemical indicator
Question
The temperature of the gas directly affects the penetration of items in the chamber. Operating temperatures range from ____________ for a "cold" cycle and ________ for a "warm" cycle.

A) 85° to 100° F and 130° to 145° F
B) 75° to 79° F and 130° to 145° F
C) 85° to 100° F and 100° to 125° F
D) 85° to 95° F and 100° to 115° F
Question
Power-driven surgical instruments (e.g., drills and saws) should be disassembled before ________________.

A) using them
B) semicritical cleaning
C) noncritical cleaning
D) steam sterilization
Question
___________________ is used to sterilize objects that cannot tolerate the heat, moisture, and pressure of steam sterilization.

A) Glutaraldehyde solution
B) Peracetic acid
C) Gas plasma
D) Ethylene oxide
Question
The recommended practice to damp dust the surgical lights, furniture, and fixed equipment in the operating suite is ___________.

A) at the end of the day
B) before the beginning of each shift
C) before each case of the day
D) before the first case of the day
Question
The phrase flash sterilization has been replaced by _____________ sterilization, in which unwrapped surgical equipment is sterilized by a high-vacuum steam sterilization method just before use.

A) just-in-time
B) quick
C) right on time
D) immediate-use steam sterilization-IUSS
Question
Because paper products are difficult or impossible to decontaminate, patient's charts, x-rays, and laboratory documentation should be ________.

A) left outside of the surgical suite
B) kept free from contamination
C) flash sterilized
D) immediately placed in plastic bags
Question
Class ____ indicators measure parameters. Examples include the Bowie-Dick and daily air-removal tests for the presence of pure air (no steam) in the sterilization chamber.

A) 4
B) 2
C) G
D) L
Question
Sterile instruments and supplies are loaded onto the ___________ before surgery and transported to the surgical suite.

A) case cart
B) elevator
C) personnel
D) conveyor
Question
Class _______ indicators are used for internal pack control of each cycle run, not for the overall performance of the sterilizer for all cycles.

A) 2
B) 6
C) 4
D) 5
Question
The ______________ sterilizer operates on the principle that air is heavier than steam.

A) dynamic
B) gravity displacement
C) unconditioned
D) preconditioned
Question
______________ items must be sterile. These items enter sterile tissue or the vascular system.

A) Semicritical
B) Noncritical
C) Critical
D) Low critical
Question
The Spaulding classification of reprocessing instruments and patient materials assigns three risk levels based on the specific region of the body where the device will be used. These levels are critical, semicritical, and ________.

A) noncritical
B) uncritical
C) ultra-critical
D) low-critical
Question
Two types of steam sterilizers are used in the clinical setting: __________.

A) gravity displacement and Sterrad
B) gravity displacement and dynamic
C) dynamic and internal
D) preconditioned and unconditioned
Question
The purpose of wrapping an item before sterilization is to protect it from _____________ after the sterilization process.

A) light
B) damage
C) infection
D) contamination
Question
Class ________ is represented by multivariable indicators that react to two or more parameters. An example is internal chemical indicators printed on a paper strip.

A) 4
B) 2
C) L
D) G
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Used for anesthesia equipment, gastrointestinal endoscopes, bronchoscopes
Question
___________ is a skilled, certified profession that requires expertise in the science and practice of materials management, decontamination, and sterilization.

A) Certified Surgical Technologists
B) Sterile Processing Technicians
C) Enzymatic cleaner
D) High vacuum sterilizer
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Must be sterile
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Laryngoscopes, bronchoscopes, and endotracheal tubes
Question
The important factor to remember about ___________ is that they do not indicate sterility, only that certain conditions for sterility have been met.

A) indicators
B) Bowie-Dick tests
C) detergents
D) case cart systems
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Include vascular and urinary catheters
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Can include bed linens, crutches, tables
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Come into contact with mucous membranes or nonintact skin
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Used for surgical instruments, implants, and needles
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Used for noncritical items
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Process by which all microorganisms, including spores, are destroyed
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Monitored by chemical and biological methods to ensure patient safety
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Must be sterilized before use on a patient
Question
The ______________sterilizer pulls air from the chamber with vacuum force and replaces it with steam. As air is pumped into the chamber, steam enters in pulsed phases. Air is completely removed with positive and negative pressure pulses. As the pressure increases, so does the temperature of the steam inside the sterilizer.

A) dynamic air-removal (prevacuum)
B) gravity displacement
C) unconditioned
D) preconditioned
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Not required to be sterile because they do not penetrate intact tissues
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Uses steam, ethylene oxide, peracetic acid, or cobalt-60
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Uses isopropyl alcohol 70% to 90%, glutaraldehyde, and iodophor solution
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Objects that enter sterile tissue or the vascular system
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Exposed to the skin but not mucous membranes
Question
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Stethoscopes, blood pressure, and tourniquet cuffs
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/40
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 10: Decontamination, Sterilization, and Disinfection
1
Which class includes indicators that respond to only one critical parameter with an exact value?

A) 2
B) 5
C) 1
D) 3
D
2
There are three distinct phases in all types of steam sterilizers. __________ is when air is removed from the chamber and replaced with steam.

A) Conditioning
B) Exposure
C) Parameter
D) Indication
A
3
The ultrasonic cleaner removes debris from instruments by a process called __________.

A) cavitation
B) agitation
C) osculation
D) both A and B
A
4
Which class includes indicators that are the most exacting and accurate of all indicators and that react to all critical values over a specified range in the sterilization process?

A) 5
B) 4
C) 3
D) 2
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
5
A _________________ is a paper strip or specially treated tape that changes color when exposed to a specific temperature.

A) wrapping paper
B) litmus paper
C) paper monitor
D) chemical indicator
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
6
The temperature of the gas directly affects the penetration of items in the chamber. Operating temperatures range from ____________ for a "cold" cycle and ________ for a "warm" cycle.

A) 85° to 100° F and 130° to 145° F
B) 75° to 79° F and 130° to 145° F
C) 85° to 100° F and 100° to 125° F
D) 85° to 95° F and 100° to 115° F
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
7
Power-driven surgical instruments (e.g., drills and saws) should be disassembled before ________________.

A) using them
B) semicritical cleaning
C) noncritical cleaning
D) steam sterilization
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
8
___________________ is used to sterilize objects that cannot tolerate the heat, moisture, and pressure of steam sterilization.

A) Glutaraldehyde solution
B) Peracetic acid
C) Gas plasma
D) Ethylene oxide
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
9
The recommended practice to damp dust the surgical lights, furniture, and fixed equipment in the operating suite is ___________.

A) at the end of the day
B) before the beginning of each shift
C) before each case of the day
D) before the first case of the day
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
10
The phrase flash sterilization has been replaced by _____________ sterilization, in which unwrapped surgical equipment is sterilized by a high-vacuum steam sterilization method just before use.

A) just-in-time
B) quick
C) right on time
D) immediate-use steam sterilization-IUSS
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
11
Because paper products are difficult or impossible to decontaminate, patient's charts, x-rays, and laboratory documentation should be ________.

A) left outside of the surgical suite
B) kept free from contamination
C) flash sterilized
D) immediately placed in plastic bags
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
12
Class ____ indicators measure parameters. Examples include the Bowie-Dick and daily air-removal tests for the presence of pure air (no steam) in the sterilization chamber.

A) 4
B) 2
C) G
D) L
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
13
Sterile instruments and supplies are loaded onto the ___________ before surgery and transported to the surgical suite.

A) case cart
B) elevator
C) personnel
D) conveyor
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
14
Class _______ indicators are used for internal pack control of each cycle run, not for the overall performance of the sterilizer for all cycles.

A) 2
B) 6
C) 4
D) 5
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
15
The ______________ sterilizer operates on the principle that air is heavier than steam.

A) dynamic
B) gravity displacement
C) unconditioned
D) preconditioned
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
16
______________ items must be sterile. These items enter sterile tissue or the vascular system.

A) Semicritical
B) Noncritical
C) Critical
D) Low critical
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
17
The Spaulding classification of reprocessing instruments and patient materials assigns three risk levels based on the specific region of the body where the device will be used. These levels are critical, semicritical, and ________.

A) noncritical
B) uncritical
C) ultra-critical
D) low-critical
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
18
Two types of steam sterilizers are used in the clinical setting: __________.

A) gravity displacement and Sterrad
B) gravity displacement and dynamic
C) dynamic and internal
D) preconditioned and unconditioned
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
19
The purpose of wrapping an item before sterilization is to protect it from _____________ after the sterilization process.

A) light
B) damage
C) infection
D) contamination
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
20
Class ________ is represented by multivariable indicators that react to two or more parameters. An example is internal chemical indicators printed on a paper strip.

A) 4
B) 2
C) L
D) G
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
21
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Used for anesthesia equipment, gastrointestinal endoscopes, bronchoscopes
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
22
___________ is a skilled, certified profession that requires expertise in the science and practice of materials management, decontamination, and sterilization.

A) Certified Surgical Technologists
B) Sterile Processing Technicians
C) Enzymatic cleaner
D) High vacuum sterilizer
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
23
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Must be sterile
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
24
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Laryngoscopes, bronchoscopes, and endotracheal tubes
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
25
The important factor to remember about ___________ is that they do not indicate sterility, only that certain conditions for sterility have been met.

A) indicators
B) Bowie-Dick tests
C) detergents
D) case cart systems
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
26
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Include vascular and urinary catheters
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
27
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Can include bed linens, crutches, tables
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
28
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Come into contact with mucous membranes or nonintact skin
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
29
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Used for surgical instruments, implants, and needles
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
30
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Used for noncritical items
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
31
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Process by which all microorganisms, including spores, are destroyed
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
32
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Monitored by chemical and biological methods to ensure patient safety
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
33
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Must be sterilized before use on a patient
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
34
The ______________sterilizer pulls air from the chamber with vacuum force and replaces it with steam. As air is pumped into the chamber, steam enters in pulsed phases. Air is completely removed with positive and negative pressure pulses. As the pressure increases, so does the temperature of the steam inside the sterilizer.

A) dynamic air-removal (prevacuum)
B) gravity displacement
C) unconditioned
D) preconditioned
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
35
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Not required to be sterile because they do not penetrate intact tissues
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
36
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Uses steam, ethylene oxide, peracetic acid, or cobalt-60
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
37
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Decontamination
b.Disinfection
c.Sterilization
Uses isopropyl alcohol 70% to 90%, glutaraldehyde, and iodophor solution
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
38
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Objects that enter sterile tissue or the vascular system
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
39
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Exposed to the skin but not mucous membranes
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
40
Choose from the terms listed and match them with their most correct description. You may use the same answer more than once.
a.Critical items
b.Semicritical items
c.Noncritical items
Stethoscopes, blood pressure, and tourniquet cuffs
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 40 flashcards in this deck.