Deck 11: Multislice Computed Tomography: Physical Principles and Instrumentation
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/60
Play
Full screen (f)
Deck 11: Multislice Computed Tomography: Physical Principles and Instrumentation
1
Volume CT can also be referred to as:
A) spiral CT.
B) circular CT.
C) rounded CT.
D) spherical CT.
A) spiral CT.
B) circular CT.
C) rounded CT.
D) spherical CT.
spiral CT.
2
New capabilities created as a result of the creation of spiral/helical CT include each of the following applications except:
A) CT endoscopy.
B) real-time CT fluoroscopy.
C) stroke imaging.
D) CT angiography.
A) CT endoscopy.
B) real-time CT fluoroscopy.
C) stroke imaging.
D) CT angiography.
stroke imaging.
3
All of these components are rotating parts of the spiral/helical CT scanner except the:
A) X-ray tube.
B) high-voltage generator.
C) detectors.
D) front-end memory.
A) X-ray tube.
B) high-voltage generator.
C) detectors.
D) front-end memory.
front-end memory.
4
What is the ideal pitch in spiral/helical CT?
A) 1
B) 2
C) 3
D) 4
A) 1
B) 2
C) 3
D) 4
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
5
All the following are problems that can occur from data acquisition with spiral geometry except:
A) localization of a particular slice is difficult.
B) inconsistent projection data.
C) increased patient dose.
D) streak artifacts can occur.
A) localization of a particular slice is difficult.
B) inconsistent projection data.
C) increased patient dose.
D) streak artifacts can occur.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
6
All of the following are requirements for volume scanning except:
A) continuous couch movement.
B) increased cooling capacity.
C) slip-ring technology.
D) tube memory.
A) continuous couch movement.
B) increased cooling capacity.
C) slip-ring technology.
D) tube memory.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
7
The pitch ratio is expressed as:
A) distance the table travels during 360 degrees/slice thickness.
B) slice thickness/distance the table travels during 360 degrees.
C) slice thickness + distance the table travels during 360 degrees.
D) slice thickness *distance the table travels during 360 degrees.
A) distance the table travels during 360 degrees/slice thickness.
B) slice thickness/distance the table travels during 360 degrees.
C) slice thickness + distance the table travels during 360 degrees.
D) slice thickness *distance the table travels during 360 degrees.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
8
Which method of CT scanning does interscan delay occurs?
A) Single-slice CT (SSCT) scanner
B) Slice-by-slice CT scanner
C) Volume CT scanner
D) Multislice CT (MSCT) scanner
A) Single-slice CT (SSCT) scanner
B) Slice-by-slice CT scanner
C) Volume CT scanner
D) Multislice CT (MSCT) scanner
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
9
The CT detector consists of each of these components except:
A) radiation sensor.
B) photodiodes.
C) analog to digital converter (ADC).
D) high-frequency generator.
A) radiation sensor.
B) photodiodes.
C) analog to digital converter (ADC).
D) high-frequency generator.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
10
Detector row collimation is equal to:
A) D (mm) + N.
B) D (mm) - N.
C) D (mm) * N.
D) D (mm)/N.
A) D (mm) + N.
B) D (mm) - N.
C) D (mm) * N.
D) D (mm)/N.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
11
What year was the first computed tomography (CT) scanner able to perform volume data acquisition introduced?
A) 1988
B) 1989
C) 1990
D) 1991
A) 1988
B) 1989
C) 1990
D) 1991
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
12
The radiation sensors convert ___________ to ___________.
A) light; X-ray photons
B) X-ray photons; light
C) light; electrical signals
D) electric signals; light
A) light; X-ray photons
B) X-ray photons; light
C) light; electrical signals
D) electric signals; light
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
13
All the following are typical scan parameters for spiral/helical CT scanners except:
A) table speed.
B) scan range.
C) number of revolutions.
D) patient size.
A) table speed.
B) scan range.
C) number of revolutions.
D) patient size.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
14
What allows the X-ray tube to continuously rotate so that a volume of the patient can be acquired?
A) Detector electronics
B) Long high-tension cables
C) Slip rings
D) Tube electronics
A) Detector electronics
B) Long high-tension cables
C) Slip rings
D) Tube electronics
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
15
The overall goal of MSCT is to:
A) improve volume coverage speed performance.
B) decrease patient dose.
C) improve spatial resolution.
D) increase tube memory.
A) improve volume coverage speed performance.
B) decrease patient dose.
C) improve spatial resolution.
D) increase tube memory.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
16
What is defined as the distance (in millimeters) that the CT table moves during one revolution of the X-ray tube?
A) Collimation
B) Table increment
C) Pitch
D) Couch movement
A) Collimation
B) Table increment
C) Pitch
D) Couch movement
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
17
The photodiodes convert _________ into ________.
A) light; X-ray photons
B) X-ray photons; light
C) light; electrical signals
D) electric signals; light
A) light; X-ray photons
B) X-ray photons; light
C) light; electrical signals
D) electric signals; light
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
18
Limitations of slice-by-slice sequential CT scanning include each of the following except:
A) longer examination time.
B) inaccurate generation of three-dimensional (3D) images.
C) possible omitted anatomy because of patient respiration.
D) interpolation.
A) longer examination time.
B) inaccurate generation of three-dimensional (3D) images.
C) possible omitted anatomy because of patient respiration.
D) interpolation.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
19
Which of the following describes when raw data for image reconstruction can be selected on the basis of the patient's electrocardiogram (ECG)?
A) Cardiac reconstruction
B) Gated reconstruction
C) Motion reconstruction
D) Timed reconstruction
A) Cardiac reconstruction
B) Gated reconstruction
C) Motion reconstruction
D) Timed reconstruction
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
20
All of the following terms are used to refer to MSCT except:
A) multisection CT.
B) multidetector CT.
C) multichannel CT.
D) multisystem CT.
A) multisection CT.
B) multidetector CT.
C) multichannel CT.
D) multisystem CT.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
21
Which of the following is not a type of detectors used in MSCT scanners?
A) Hybrid detectors
B) Universal detectors
C) Nonuniform detectors
D) Uniform detectors
A) Hybrid detectors
B) Universal detectors
C) Nonuniform detectors
D) Uniform detectors
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
22
In MSCT, the slice thickness is not determined by which factor?
A) Volume coverage
B) Beam width in the z-axis
C) Pitch
D) Shape and width of the reconstruction filter
A) Volume coverage
B) Beam width in the z-axis
C) Pitch
D) Shape and width of the reconstruction filter
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
23
What type of detector is used in MSCT scanners?
A) Helium gas detector
B) Solid-state scintillation detector
C) Tungsten detector
D) Xenon gas detector
A) Helium gas detector
B) Solid-state scintillation detector
C) Tungsten detector
D) Xenon gas detector
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
24
What term is used to describe the resorting of the 3D data collected from the cone-beam acquisition to a set of 2D fan-beam data?
A) Binning
B) Rebinning
C) Reformatting
D) Sampling
A) Binning
B) Rebinning
C) Reformatting
D) Sampling
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
25
As the pitch increases, the image quality:
A) increases.
B) decreases.
C) does not change.
D) has no direct relationship.
A) increases.
B) decreases.
C) does not change.
D) has no direct relationship.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
26
Pitch is directly related to:
A) patient dose.
B) kVp.
C) patient comfort.
D) detector configuration.
A) patient dose.
B) kVp.
C) patient comfort.
D) detector configuration.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
27
Which of the following is not considered a cone-beam algorithm?
A) Exact algorithms
B) Approximate algorithms
C) Opposed algorithms
D) Feldkamp-Davis-Kress (FDK) algorithm
A) Exact algorithms
B) Approximate algorithms
C) Opposed algorithms
D) Feldkamp-Davis-Kress (FDK) algorithm
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
28
The operator console controls all of the following except:
A) communication.
B) control of the gantry.
C) patient dose.
D) windowing.
A) communication.
B) control of the gantry.
C) patient dose.
D) windowing.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
29
All of the following are materials used in solid-state detectors except:
A) calcium tungsten.
B) gadolinium oxysulfide (GOS).
C) gadolinium oxide.
D) yttrium-gadolinium oxide.
A) calcium tungsten.
B) gadolinium oxysulfide (GOS).
C) gadolinium oxide.
D) yttrium-gadolinium oxide.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
30
In an MSCT scanner, what type of algorithm can be used if the number of detector rows is small?
A) Cone-beam reconstruction
B) Fan-beam reconstruction
C) x-axis reconstruction
D) z-axis reconstruction
A) Cone-beam reconstruction
B) Fan-beam reconstruction
C) x-axis reconstruction
D) z-axis reconstruction
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
31
In MSCT, a _________ beam geometry results, rather than a fan beam as in SSCT scanners.
A) circular
B) cone
C) rectangular
D) triangular
A) circular
B) cone
C) rectangular
D) triangular
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
32
What term is used to describe the number of data collection channels and the effective section thickness determined by the data acquisition system settings?
A) Detector array
B) Detector configuration
C) Detector geometry
D) Detector set
A) Detector array
B) Detector configuration
C) Detector geometry
D) Detector set
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
33
What term is used to describe the separating of the direct and complementary data trails and also results in efficient z-sampling?
A) Efficient sampling scan
B) Complete sampling scan
C) Optimized sampling scan
D) Total sampling scan
A) Efficient sampling scan
B) Complete sampling scan
C) Optimized sampling scan
D) Total sampling scan
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
34
All of the following are housed in the MSCT gantry except:
A) detectors.
B) detector electronics.
C) collimation selector.
D) X-ray tube.
A) detectors.
B) detector electronics.
C) collimation selector.
D) X-ray tube.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
35
The definition of pitch in a multislice scanner, as defined by the International Electrotechnical Commission, states:
A) P = distance the table travels per rotation (d)/total collimation (W)
B) P = distance the table travels per rotation (d) + total collimation (W)
C) P = distance the table travels per rotation (d) * total collimation (W)
D) P = total collimation (W)/distance the table travels per rotation (d)
A) P = distance the table travels per rotation (d)/total collimation (W)
B) P = distance the table travels per rotation (d) + total collimation (W)
C) P = distance the table travels per rotation (d) * total collimation (W)
D) P = total collimation (W)/distance the table travels per rotation (d)
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
36
What is the term used to describe the flipped view used for interpolated reconstruction?
A) Complementary data
B) Opposed data
C) Opposite data
D) Reciprocal data
A) Complementary data
B) Opposed data
C) Opposite data
D) Reciprocal data
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
37
If the X-ray prepatient collimation width is 24 cm and the scanner has a four-row detector array, what is the detector row collimation?
A) 4 mm
B) 5 mm
C) 6 mm
D) 7 mm
A) 4 mm
B) 5 mm
C) 6 mm
D) 7 mm
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
38
The computer systems of MSCT scanners have hardware that provides all of the following except:
A) high-speed processing.
B) image communication.
C) image reconstruction.
D) postprocessing operations.
A) high-speed processing.
B) image communication.
C) image reconstruction.
D) postprocessing operations.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
39
In 1992, the first modern multislice scanner was introduced by:
A) Elscint.
B) GE Healthcare Systems.
C) Siemens Healthcare Systems.
D) Toshiba Healthcare Systems.
A) Elscint.
B) GE Healthcare Systems.
C) Siemens Healthcare Systems.
D) Toshiba Healthcare Systems.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
40
Which of the following is not a physical property of detectors?
A) High luminescence efficiency
B) Large dynamic range
C) Small afterglow
D) Recyclable value
A) High luminescence efficiency
B) Large dynamic range
C) Small afterglow
D) Recyclable value
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
41
All of the following are advantages of MSCT except:
A) increased speed and volume coverage.
B) improved spatial resolution.
C) reduction of radiation exposure.
D) decreased contrast resolution.
A) increased speed and volume coverage.
B) improved spatial resolution.
C) reduction of radiation exposure.
D) decreased contrast resolution.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
42
When the slice thickness is equal to the pixel size, the data acquired are said to be:
A) anisotropic.
B) distropic.
C) isotropic.
D) unitropic.
A) anisotropic.
B) distropic.
C) isotropic.
D) unitropic.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
43
An algorithm common in MSCT scanners is the FDK algorithm.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
44
An early pioneer in the development of the technique of volume rendering was Dr. Willi A. Kalender.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
45
MSCT scanners utilize xenon gas detectors for their high X-ray absorption.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
46
The ideal pitch in spiral/helical CT is 2:1.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
47
Which of the following is not a parameter of image quality?
A) Spatial resolution
B) Patient dose
C) Contrast resolution
D) Noise
A) Spatial resolution
B) Patient dose
C) Contrast resolution
D) Noise
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
48
Slice-by-slice sequential CT creates inaccurate generation of 3D images resulting in partial voluming artifacts.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
49
Even with slip-ring technology, long high-tension cables are needed for data transfer.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
50
The overall goal of single-slice spiral/helical volume CT is to increase the volume coverage speed compared with that of the conventional CT scanner.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
51
The X-ray tube and detectors are able to rotate continuously during data collection as a result of slip-ring technology.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
52
A number of interpolation algorithms are used to produce the planar data set, but linear interpolation (LI) is the simplest approach.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
53
Dual-source CT (DSCT) scanners are primarily used for:
A) cardiac imaging.
B) quantitative imaging.
C) pulmonary imaging.
D) virtual colonoscopy.
A) cardiac imaging.
B) quantitative imaging.
C) pulmonary imaging.
D) virtual colonoscopy.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
54
The first model of the 256-slice 4D CT scanner was developed in:
A)2001.
B)2002.
C)2003.
D)2004.
A)2001.
B)2002.
C)2003.
D)2004.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
55
Pitch affects both image quality and patient dose.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
56
DSCT scanners require two operator consoles to input each examination's scanning parameters.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
57
The first step in volume scanning is analog to digital conversion.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
58
Another application of the DSCT scanner includes imaging of obese patients.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
59
To prevent anode movement under the stress of subsecond acceleration, new X-ray tubes have the anode mounted on a shaft that extends along the tube.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
60
A pitch greater than 1 will result in an increased dose.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck