Deck 8: The Microscope

Full screen (f)
exit full mode
Question
The image produced by an SEM is initially displayed on:

A)An X-ray analyzer.
B)Photographic paper.
C)An X-ray film.
D)A cathode ray tube.
Use Space or
up arrow
down arrow
to flip the card.
Question
A compound microscope is equipped with two objective lenses (10x and 45x)and has a 10x ocular lens. The highest magnification attainable with this instrument is:

A)65x
B)100x
C)650x
D)450x
Question
Which microscope has the largest potential working distance?

A)Stereoscopic
B)Comparison
C)Polarizing
D)Compound
Question
________ are used to focus the SEM (scanning electron microscope).

A)Analyzers
B)Lenses
C)Polarizers
D)Electromagnets
Question
A comparison microscope designed to examine bullets and fibers is equipped with:

A)Vertical illumination.
B)Transmitted illumination.
C)Oblique illumination.
D)Both A and B.
Question
A parfocal microscope:

A)Eliminates the need to stain the specimen to be viewed.
B)Has two ocular lenses.
C)Requires a polarized light source.
D)Allows for ease of focusing when switching from low to high power.
Question
Which microscope provides a right-side-up image?

A)Comparison
B)Stereoscopic
C)Compound
D)Polarizing
Question
Which microscope plots an absorption spectrum of the item under examination?

A)Polarizing
B)Comparison
C)Stereoscopic
D)Microspectrophotometer
Question
In the design of a polarizing microscope, the polarizer is placed between the:

A)Specimen and the analyzer.
B)Analyzer and the eyepiece.
C)Light source and the sample stage.
D)Sample stage and the analyzer.
Question
Which microscope can be linked to an X-ray analyzer?

A)SEM
B)Microspectrophotometer
C)Stereoscopic
D)Polarizing
Question
Which microscope provides the highest resolution and greatest depth of focus?

A)SEM
B)Comparison
C)Compound
D)Stereoscopic
Question
As the magnification of the compound microscope is increased, the field of view:

A)Decreases.
B)Remains the same.
C)Increases.
D)Becomes more focused.
Question
As the magnifying power of the compound microscope increases, the depth of focus:

A)Remains the same.
B)Decreases.
C)Increases.
D)Becomes less focused.
Question
Which microscope is best suited to the study of birefringent minerals and fibers?

A)Stereoscopic
B)Microspectrophotometer
C)Polarizing
D)Comparison
Question
In order to examine an opaque object with a compound microscope, one must:

A)Use transmitted illumination.
B)Light the object from beneath the stage.
C)Use reflected illumination.
D)Stain the object before viewing it.
Question
When using a compound microscope, the areas above and below the depth of focus are best viewed by adjusting the:

A)Eyepiece lens.
B)Fine or coarse adjustment.
C)Intensity of the illumination.
D)Numerical aperture.
Question
Which microscope is most likely to be used as a tool for determining whether or not a suspect has recently fired a gun?

A)Comparison
B)Polarizing
C)SEM
D)Stereoscopic
Question
Normally with a polarizing microscope, the polarizer and analyzer are set:

A)Parallel to each other.
B)So that maximum plane polarized light can reach the eyepiece.
C)Perpendicular to each other.
D)So that they are in constant motion.
Question
The condenser of a compound microscope is located:

A)At the base.
B)Within the body tube.
C)Beneath the stage.
D)Between the coarse and fine adjustments.
Question
A microscope with which light source, when linked to a spectrophotometer, will provide a "fingerprint" spectrum of the object being viewed?

A)Visible
B)Plane polarized
C)IR (infrareD)
D)UV (ultraviolet)
Question
An object with the letter "L" is viewed under low power of a compound microscope. The image would appear as:

A)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
B)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
C)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
D)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
Question
Which of the following is FALSE?

A)The scanning electron microscope (SEM)produces an image by aiming a beam of electrons onto a specimen.
B)The major attraction of the SEM is its high magnification and depth of field.
C)The SEM produces an image that is stereoscopic in appearance.
D)Microwaves are generated when the electron beam of the SEM strikes a target.
Question
A transparent specimen is viewed through a microscope using ________ light while an opaque object requires ________ illumination.

A)Transmitted; stereoscopic
B)Confocal; transmitted
C)Vertical; horizontal
D)Transmitted; vertical
Question
Components of a compound microscope include all of the following EXCEPT:

A)Expander.
B)Stage.
C)Coarse adjustment.
D)Condenser.
Question
The size of the specimen area that can be seen is known as the:

A)Depth of field.
B)Field of view.
C)Stage size.
D)Objective.
Question
The microscope examination of a bullet requires:

A)Transmitted light.
B)Reflected light.
C)Condensed light.
D)All of the above.
Question
Which of the following statements is FALSE?

A)If the polarizer and analyzer of a polarizing microscope are placed parallel to each other, no light will penetrate.
B)Light confined to a single plane of vibration is said to be polarized.
C)Many crystals are birefringent.
D)The lens nearest the specimen is called the objective lens.
Question
When the SEM's primary electron beam bombards a specimen, it causes the emission of:

A)Electrons from elements of the upper layer of the specimen.
B)X-rays from the target.
C)Gamma rays from the target.
D)Both A and B
Question
An objective lens with a numerical aperture of 1.50 can separate details at half the distance of a lens with a numerical aperture of:

A)0)65.
B)3)00.
C)30.00.
D)0)75.
Question
What is the most important tool of the firearms examiner?

A)Compound microscope
B)Comparison microscope
C)Stereoscopic microscope
D)Polarizing microscope
Question
What instrument can be used to view a single fiber found at a crime scene and identify its generic class?

A)Infrared microspectrophotometer
B)Stereoscopic microscope
C)Polarizing microscope
D)Both A and C
Question
The magnification power of a microscope equals the magnifying power of the:

A)Eyepiece lens.
B)Objective lens.
C)Objective lens multiplied by two.
D)Objective lens multiplied by the eyepiece lens.
Question
A type of image that cannot be viewed directly is called a(n)________ image.

A)Real
B)Imaginary
C)Reflected
D)Virtual
Question
Which type of pollen is rarely deposited on objects EXCEPT by direct contact with the plant?

A)Anemophilous
B)Exine
C)Entomophilous
D)Gametophyte
Question
Crystals that are ________ produce two planes of polarized light, each perpendicular to the other.

A)Amorphous
B)Solid
C)Birefringent
D)Colored
Question
If crystals of unknown origin are viewed under a polarizing microscope and appear dark, what can be concluded about the crystals?

A)The crystals are not heroin crystals.
B)The crystals are colorless.
C)The crystals are polarizing.
D)The crystals are non-polarizing.
Question
Which of these is NOT part of the optical system of a compound microscope?

A)Abbé condenser
B)Objective lens
C)Eyepiece lens
D)Body tube
Question
Palynology is the study of:

A)Fish.
B)Insects.
C)Birds.
D)Spores.
Question
A microscope uses a combination of ________ to magnify an image.

A)Stages
B)Mirrors
C)Lenses
D)Confocals
Question
The major advantages of the SEM image include all of the following EXCEPT:

A)High magnification.
B)High reproducibility.
C)High resolution.
D)Great depth of focus.
Question
Transmitted illumination can be used only with specimens that are transparent.
Question
The scanning electron microscope produces an image by aiming a beam of electrons onto a specimen.
Question
A compound microscope produces greater magnification because it uses two lenses to enlarge the object being viewed instead of just one.
Question
Many crystals are birefringent.
Question
The microscopic examination of a bullet requires reflected light.
Question
If the polarizer and analyzer of a polarizing microscope are placed parallel to each other, no light will penetrate.
Question
The lens nearest the specimen is called the ocular lens.
Question
The magnification power of a microscope equals the magnifying power of the objective lens multiplied by two.
Question
A forensic scientist would use vertical illumination when studying opaque specimens.
Question
An IR spectrum is unique for every chemical substance.
Question
The body tube is part of the optical system of a compound microscope.
Question
A virtual image can be seen directly with the naked eye.
Question
The pattern of the pollen grain surface is called:

A)Sculpturing.
B)Apertures.
C)Exine.
D)Pollen rain.
Question
The stereoscopic microscope forms an inverted and reversed image.
Question
As magnifying power increases, the microscope's depth of focus decreases.
Question
The SEM produces an image that is stereoscopic in appearance.
Question
The stereoscopic microscope is the most frequently used microscope in the crime laboratory.
Question
Bullets fired through the same barrel display comparable markings, called striations, caused by the rifling of the barrel.
Question
The stereoscopic microscope has a narrow field of view.
Question
As magnifying power increases, the microscope's field of view also increases.
Question
With opaque specimens, the light source must be placed ________ the specimen and reflected off the specimen's surface and into the lens.
Question
The ________ allows the forensic scientist to view a particle under a microscope while at the same time obtaining its absorption spectrum.
Question
It is not possible to identify a geographical origin by the type and percentages of airborne pollen grains.
Question
The infrared microspectrophotometer is used to analyze fibers and paints.
Question
Unique shapes, aperture type, and surface ________ are typically used to identify spore samples.
Question
The ________ microscope presents a three-dimensional image of an object.
Question
Pollen and spores can be used to provide links between a crime scene and a person or object.
Question
If the ________ on two bullets viewed through a comparison microscope are alike, the examiner can conclude that both bullets traveled through the same barrel.
Question
The pollen expert's first task is to calculate the pollen ________ for the crime scene.
Question
The major attraction of the ________ is its high magnification and depth of field.
Question
A ________ uses a stream of electrons to create an image of the specimen being studied.
Question
The ________ lens magnifies the real, enlarged image created by the objective lens, producing a greatly enlarged virtual image of the object.
Question
The most important tool of the firearms examiner is the ________ microscope.
Question
The pollen of entomophilous plants is dispersed by wind.
Question
A(n)________ image is an image formed when light rays converge on a surface.
Question
________ aperture measures the ability of an objective lens to resolve details into separate images instead of one blurred image.
Question
Light confined to a single plane of vibration is said to be ________.
Question
A ________ microscope is used to make side-by-side comparisons of specimens.
Question
Pollen grains are the single-celled male ________ of seed-bearing plants.
Question
________ illumination is illumination of a specimen from above.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/101
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 8: The Microscope
1
The image produced by an SEM is initially displayed on:

A)An X-ray analyzer.
B)Photographic paper.
C)An X-ray film.
D)A cathode ray tube.
D
2
A compound microscope is equipped with two objective lenses (10x and 45x)and has a 10x ocular lens. The highest magnification attainable with this instrument is:

A)65x
B)100x
C)650x
D)450x
D
3
Which microscope has the largest potential working distance?

A)Stereoscopic
B)Comparison
C)Polarizing
D)Compound
A
4
________ are used to focus the SEM (scanning electron microscope).

A)Analyzers
B)Lenses
C)Polarizers
D)Electromagnets
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
5
A comparison microscope designed to examine bullets and fibers is equipped with:

A)Vertical illumination.
B)Transmitted illumination.
C)Oblique illumination.
D)Both A and B.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
6
A parfocal microscope:

A)Eliminates the need to stain the specimen to be viewed.
B)Has two ocular lenses.
C)Requires a polarized light source.
D)Allows for ease of focusing when switching from low to high power.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
7
Which microscope provides a right-side-up image?

A)Comparison
B)Stereoscopic
C)Compound
D)Polarizing
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
8
Which microscope plots an absorption spectrum of the item under examination?

A)Polarizing
B)Comparison
C)Stereoscopic
D)Microspectrophotometer
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
9
In the design of a polarizing microscope, the polarizer is placed between the:

A)Specimen and the analyzer.
B)Analyzer and the eyepiece.
C)Light source and the sample stage.
D)Sample stage and the analyzer.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
10
Which microscope can be linked to an X-ray analyzer?

A)SEM
B)Microspectrophotometer
C)Stereoscopic
D)Polarizing
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
11
Which microscope provides the highest resolution and greatest depth of focus?

A)SEM
B)Comparison
C)Compound
D)Stereoscopic
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
12
As the magnification of the compound microscope is increased, the field of view:

A)Decreases.
B)Remains the same.
C)Increases.
D)Becomes more focused.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
13
As the magnifying power of the compound microscope increases, the depth of focus:

A)Remains the same.
B)Decreases.
C)Increases.
D)Becomes less focused.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
14
Which microscope is best suited to the study of birefringent minerals and fibers?

A)Stereoscopic
B)Microspectrophotometer
C)Polarizing
D)Comparison
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
15
In order to examine an opaque object with a compound microscope, one must:

A)Use transmitted illumination.
B)Light the object from beneath the stage.
C)Use reflected illumination.
D)Stain the object before viewing it.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
16
When using a compound microscope, the areas above and below the depth of focus are best viewed by adjusting the:

A)Eyepiece lens.
B)Fine or coarse adjustment.
C)Intensity of the illumination.
D)Numerical aperture.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
17
Which microscope is most likely to be used as a tool for determining whether or not a suspect has recently fired a gun?

A)Comparison
B)Polarizing
C)SEM
D)Stereoscopic
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
18
Normally with a polarizing microscope, the polarizer and analyzer are set:

A)Parallel to each other.
B)So that maximum plane polarized light can reach the eyepiece.
C)Perpendicular to each other.
D)So that they are in constant motion.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
19
The condenser of a compound microscope is located:

A)At the base.
B)Within the body tube.
C)Beneath the stage.
D)Between the coarse and fine adjustments.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
20
A microscope with which light source, when linked to a spectrophotometer, will provide a "fingerprint" spectrum of the object being viewed?

A)Visible
B)Plane polarized
C)IR (infrareD)
D)UV (ultraviolet)
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
21
An object with the letter "L" is viewed under low power of a compound microscope. The image would appear as:

A)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)
B)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)
C)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)
D)
<strong>An object with the letter L is viewed under low power of a compound microscope. The image would appear as:</strong> A)   B)   C)   D)
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
22
Which of the following is FALSE?

A)The scanning electron microscope (SEM)produces an image by aiming a beam of electrons onto a specimen.
B)The major attraction of the SEM is its high magnification and depth of field.
C)The SEM produces an image that is stereoscopic in appearance.
D)Microwaves are generated when the electron beam of the SEM strikes a target.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
23
A transparent specimen is viewed through a microscope using ________ light while an opaque object requires ________ illumination.

A)Transmitted; stereoscopic
B)Confocal; transmitted
C)Vertical; horizontal
D)Transmitted; vertical
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
24
Components of a compound microscope include all of the following EXCEPT:

A)Expander.
B)Stage.
C)Coarse adjustment.
D)Condenser.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
25
The size of the specimen area that can be seen is known as the:

A)Depth of field.
B)Field of view.
C)Stage size.
D)Objective.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
26
The microscope examination of a bullet requires:

A)Transmitted light.
B)Reflected light.
C)Condensed light.
D)All of the above.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
27
Which of the following statements is FALSE?

A)If the polarizer and analyzer of a polarizing microscope are placed parallel to each other, no light will penetrate.
B)Light confined to a single plane of vibration is said to be polarized.
C)Many crystals are birefringent.
D)The lens nearest the specimen is called the objective lens.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
28
When the SEM's primary electron beam bombards a specimen, it causes the emission of:

A)Electrons from elements of the upper layer of the specimen.
B)X-rays from the target.
C)Gamma rays from the target.
D)Both A and B
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
29
An objective lens with a numerical aperture of 1.50 can separate details at half the distance of a lens with a numerical aperture of:

A)0)65.
B)3)00.
C)30.00.
D)0)75.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
30
What is the most important tool of the firearms examiner?

A)Compound microscope
B)Comparison microscope
C)Stereoscopic microscope
D)Polarizing microscope
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
31
What instrument can be used to view a single fiber found at a crime scene and identify its generic class?

A)Infrared microspectrophotometer
B)Stereoscopic microscope
C)Polarizing microscope
D)Both A and C
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
32
The magnification power of a microscope equals the magnifying power of the:

A)Eyepiece lens.
B)Objective lens.
C)Objective lens multiplied by two.
D)Objective lens multiplied by the eyepiece lens.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
33
A type of image that cannot be viewed directly is called a(n)________ image.

A)Real
B)Imaginary
C)Reflected
D)Virtual
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
34
Which type of pollen is rarely deposited on objects EXCEPT by direct contact with the plant?

A)Anemophilous
B)Exine
C)Entomophilous
D)Gametophyte
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
35
Crystals that are ________ produce two planes of polarized light, each perpendicular to the other.

A)Amorphous
B)Solid
C)Birefringent
D)Colored
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
36
If crystals of unknown origin are viewed under a polarizing microscope and appear dark, what can be concluded about the crystals?

A)The crystals are not heroin crystals.
B)The crystals are colorless.
C)The crystals are polarizing.
D)The crystals are non-polarizing.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
37
Which of these is NOT part of the optical system of a compound microscope?

A)Abbé condenser
B)Objective lens
C)Eyepiece lens
D)Body tube
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
38
Palynology is the study of:

A)Fish.
B)Insects.
C)Birds.
D)Spores.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
39
A microscope uses a combination of ________ to magnify an image.

A)Stages
B)Mirrors
C)Lenses
D)Confocals
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
40
The major advantages of the SEM image include all of the following EXCEPT:

A)High magnification.
B)High reproducibility.
C)High resolution.
D)Great depth of focus.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
41
Transmitted illumination can be used only with specimens that are transparent.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
42
The scanning electron microscope produces an image by aiming a beam of electrons onto a specimen.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
43
A compound microscope produces greater magnification because it uses two lenses to enlarge the object being viewed instead of just one.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
44
Many crystals are birefringent.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
45
The microscopic examination of a bullet requires reflected light.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
46
If the polarizer and analyzer of a polarizing microscope are placed parallel to each other, no light will penetrate.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
47
The lens nearest the specimen is called the ocular lens.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
48
The magnification power of a microscope equals the magnifying power of the objective lens multiplied by two.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
49
A forensic scientist would use vertical illumination when studying opaque specimens.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
50
An IR spectrum is unique for every chemical substance.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
51
The body tube is part of the optical system of a compound microscope.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
52
A virtual image can be seen directly with the naked eye.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
53
The pattern of the pollen grain surface is called:

A)Sculpturing.
B)Apertures.
C)Exine.
D)Pollen rain.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
54
The stereoscopic microscope forms an inverted and reversed image.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
55
As magnifying power increases, the microscope's depth of focus decreases.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
56
The SEM produces an image that is stereoscopic in appearance.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
57
The stereoscopic microscope is the most frequently used microscope in the crime laboratory.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
58
Bullets fired through the same barrel display comparable markings, called striations, caused by the rifling of the barrel.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
59
The stereoscopic microscope has a narrow field of view.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
60
As magnifying power increases, the microscope's field of view also increases.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
61
With opaque specimens, the light source must be placed ________ the specimen and reflected off the specimen's surface and into the lens.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
62
The ________ allows the forensic scientist to view a particle under a microscope while at the same time obtaining its absorption spectrum.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
63
It is not possible to identify a geographical origin by the type and percentages of airborne pollen grains.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
64
The infrared microspectrophotometer is used to analyze fibers and paints.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
65
Unique shapes, aperture type, and surface ________ are typically used to identify spore samples.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
66
The ________ microscope presents a three-dimensional image of an object.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
67
Pollen and spores can be used to provide links between a crime scene and a person or object.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
68
If the ________ on two bullets viewed through a comparison microscope are alike, the examiner can conclude that both bullets traveled through the same barrel.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
69
The pollen expert's first task is to calculate the pollen ________ for the crime scene.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
70
The major attraction of the ________ is its high magnification and depth of field.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
71
A ________ uses a stream of electrons to create an image of the specimen being studied.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
72
The ________ lens magnifies the real, enlarged image created by the objective lens, producing a greatly enlarged virtual image of the object.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
73
The most important tool of the firearms examiner is the ________ microscope.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
74
The pollen of entomophilous plants is dispersed by wind.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
75
A(n)________ image is an image formed when light rays converge on a surface.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
76
________ aperture measures the ability of an objective lens to resolve details into separate images instead of one blurred image.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
77
Light confined to a single plane of vibration is said to be ________.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
78
A ________ microscope is used to make side-by-side comparisons of specimens.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
79
Pollen grains are the single-celled male ________ of seed-bearing plants.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
80
________ illumination is illumination of a specimen from above.
Unlock Deck
Unlock for access to all 101 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 101 flashcards in this deck.