Deck 15: Hazardous Classified Locations
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
Play
Full screen (f)
Deck 15: Hazardous Classified Locations
1
When mixed with air, a flammable/combustible gas (or liquid-produced vapor) has a _____ of no more than 0.45 mm.
A) maximum ignition yield (MIY)
B) minimum explosive trigger (MET)
C) maximum experimental safe gap (MESG)
D) minimum ignition pressure gap (MIPG)
A) maximum ignition yield (MIY)
B) minimum explosive trigger (MET)
C) maximum experimental safe gap (MESG)
D) minimum ignition pressure gap (MIPG)
C
2
____ locations contain ignitable or combustible elements (gases, dust, fibers, etc.) in quantities sufficient to produce explosive (or ignitable) mixtures.
A) Division 1
B) Category 1
C) Division 2
D) Category 2
A) Division 1
B) Category 1
C) Division 2
D) Category 2
A
3
Hazardous (classified) locations are divided into certain categories and subcategories, otherwise known as ____.
A) sites and subsites
B) sites and locations
C) classes and divisions
D) codes and divisions
A) sites and subsites
B) sites and locations
C) classes and divisions
D) codes and divisions
C
4
All cut ends of intermediate metal conduit (IMC) and rigid metal conduit (RMC) shall be ____.
A) jacketed with aluminum or composite materials
B) reamed or otherwise finished to remove rough edges
C) grounded to a stable fixture
D) jacketed with plastic or polymer
A) jacketed with aluminum or composite materials
B) reamed or otherwise finished to remove rough edges
C) grounded to a stable fixture
D) jacketed with plastic or polymer
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
The temperature marking for organic dusts that may dehydrate or carbonize shall not exceed the lower of either the ignition temperature or ____.
A) 100°C (212°F)
B) 165°C (329°F)
C) 175°C (347°F)
D) 200°C (392°F)
A) 100°C (212°F)
B) 165°C (329°F)
C) 175°C (347°F)
D) 200°C (392°F)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Class II locations are hazardous because of the presence of ____.
A) combustible vapors
B) potential arcing
C) volatile mixtures
D) combustible dust
A) combustible vapors
B) potential arcing
C) volatile mixtures
D) combustible dust
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Areas in a garage adjacent to classified locations in which flammable vapor release is unlikely (such as a storeroom) shall be unclassified where ____.
A) designed with negative air flow
B) mechanically ventilated at a rate of four (or more) air changes per hour
C) designed with hermetical sealing around all doors
D) no electrical wiring passes within 10 feet of the pit area
A) designed with negative air flow
B) mechanically ventilated at a rate of four (or more) air changes per hour
C) designed with hermetical sealing around all doors
D) no electrical wiring passes within 10 feet of the pit area
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
Unless otherwise specified in 500.8(C)(6), equipment markings shall include: (1) class, (2) division, (3) material classification group, (4) equipment temperature, and (5) ____.
A) maximum voltage
B) material composition
C) average draw
D) ambient temperature range
A) maximum voltage
B) material composition
C) average draw
D) ambient temperature range
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
Equipment protection techniques may include explosionproof, dusttight, heremetic sealing, and ____.
A) polycoating
B) nonflammable paint
C) nonincendive
D) damping
A) polycoating
B) nonflammable paint
C) nonincendive
D) damping
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
Hazardous (classified) locations divide atmospheric identifications for Class I, Divisions 1 and 2, locations into ____.
A) Groups 1A and 2A
B) Categories A and B
C) Categories A, B, C, and D
D) Groups A, B, C, and D
A) Groups 1A and 2A
B) Categories A and B
C) Categories A, B, C, and D
D) Groups A, B, C, and D
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Article 515 covers a property or portion of a property where ____ are received by tank vessel, pipelines, tank car, or tank vehicle and are stored or blended in bulk for the purpose of distribution.
A) chemicals
B) natural gases
C) flammable liquids
D) flammable vapors
A) chemicals
B) natural gases
C) flammable liquids
D) flammable vapors
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Additional seals apply to the ____ of the Class I locations.
A) anterior and posterior sections
B) distal and medial boundaries
C) conduit entrances
D) horizontal as well as vertical boundaries
A) anterior and posterior sections
B) distal and medial boundaries
C) conduit entrances
D) horizontal as well as vertical boundaries
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Conduit/cable system seals minimize the passage of ____ and prevent the passage of flames from one portion of the electrical installation to another through the conduit.
A) sparks
B) water
C) electrical flow
D) gas/vapors
A) sparks
B) water
C) electrical flow
D) gas/vapors
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Tensile stress at Type MI cable termination fittings can be avoided by ____.
A) proper installation and support methods
B) choosing the appropriate cable diameter
C) proper grounding techniques
D) correct insulation methods
A) proper installation and support methods
B) choosing the appropriate cable diameter
C) proper grounding techniques
D) correct insulation methods
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Type PVC conduit, Type RTRC conduit, and Type HDPE conduit can be used when first surrounded by at least ____ of concrete, followed by a minimum cover of 24 in.(600 mm) (top of conduit to grade).
A) 2 in.(50 mm)
B) 4 in.(100 mm)
C) 8 in.(200 mm)
D) 12 in.(300 mm)
A) 2 in.(50 mm)
B) 4 in.(100 mm)
C) 8 in.(200 mm)
D) 12 in.(300 mm)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
Group G is the catchall group whose atmospheres contain combustible dusts not included in Group E or F, including ____.
A) flour, grain, wood, plastic, and chemicals
B) metal and polymer
C) paper and paint
D) chemicals, metal, and rubber products
A) flour, grain, wood, plastic, and chemicals
B) metal and polymer
C) paper and paint
D) chemicals, metal, and rubber products
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Garages used for parking or storage are ____.
A) permitted to be unclassified
B) classified as Division I
C) classified according to type of vehicle
D) classified as Division II
A) permitted to be unclassified
B) classified as Division I
C) classified according to type of vehicle
D) classified as Division II
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
Electrical wiring and electrical utilization equipment located within 5 ft (1525 mm) of a vapor source shall be suitable for _____ locations.
A) Class I
B) Class II
C) Class III
D) Class IV
A) Class I
B) Class II
C) Class III
D) Class IV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Sealing compound shall ____.
A) have a melting point of 93°F or higher
B) cement sections of conduit together
C) not be affected by surrounding atmosphere or liquids
D) provide a seal against the passage of sparks
A) have a melting point of 93°F or higher
B) cement sections of conduit together
C) not be affected by surrounding atmosphere or liquids
D) provide a seal against the passage of sparks
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
The simultaneous presence of flammable gases, flammable liquid-produced vapors, combustible liquid-produced vapors, or combustible dusts shall be considered when determining the ____ of the electrical equipment.
A) grounding arrangement
B) safe operating temperature
C) shielding
D) sparking potential
A) grounding arrangement
B) safe operating temperature
C) shielding
D) sparking potential
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Askarel-containing transformers rated in excess of 25 kVA shall have ____.
A) negative airflow to all adjacent areas within a scope of 10 ft
B) insulated grounding wires connecting the transformer case and an earth ground
C) at least 6 in.(150 mm) of airspace between the transformer case and any adjacent combustible material
D) a properly installed chimney
A) negative airflow to all adjacent areas within a scope of 10 ft
B) insulated grounding wires connecting the transformer case and an earth ground
C) at least 6 in.(150 mm) of airspace between the transformer case and any adjacent combustible material
D) a properly installed chimney
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
The quantity of combustible dust that may be present and the ____ are factors that merit consideration in determining the classification and may result in an unclassified area.
A) adequacy of dust removal systems
B) potential for arcing
C) chemical composition of the dust
D) proximity of sprinkler systems
A) adequacy of dust removal systems
B) potential for arcing
C) chemical composition of the dust
D) proximity of sprinkler systems
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Class III, Division 1 and 2 portable lighting equipment shall have handles and ____.
A) substantial guards
B) sealed casings
C) positive airflow
D) cross-wiring
A) substantial guards
B) sealed casings
C) positive airflow
D) cross-wiring
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Class III locations are hazardous because of the presence of ____, or where materials producing combustible flyings are handled, manufactured, or used, even though they are not likely to be airborne in quantities sufficient to produce ignitable mixtures.
A) volatile gases
B) unstable vapors
C) fine dust
D) easily ignitable fibers
A) volatile gases
B) unstable vapors
C) fine dust
D) easily ignitable fibers
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Class II, Division 1 locations require interlocked armor Type MC cable having an overall jacket of suitable polymeric material and provided with termination fittings and ____.
A) LFLC with listed fittings
B) LFNC with listed fittings
C) LFLD with listed fittings
D) LFMD with listed fittings
A) LFLC with listed fittings
B) LFNC with listed fittings
C) LFLD with listed fittings
D) LFMD with listed fittings
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck