Deck 9: General Nec Requirements for Rough-In Wiring
1
Section 300.20(A) requires conductors carrying alternating current and installed in ferrous (iron) metal boxes to be arranged to avoid heating the surrounding metal by magnetic induction.
True
2
The fixed glass section of a sliding glass door unit is counted as regular wall space when determining receptacle placement in a room.
True
3
When holes are bored through wood framing members for the purpose of installing an electrical cable, the holes must be bored so the edge of the hole is not less than __________ from the nearest edge of the wood framing member.
A) 1 inch
B) 1-1/4 inches
C) 1-1/2 inches
D) 1-3/4 inches
A) 1 inch
B) 1-1/4 inches
C) 1-1/2 inches
D) 1-3/4 inches
B
4
An electrician must cut a groove into a wood beam to install Type NM cable to a certain location.If the groove is cut into the beam 1-1/8 inches, a steel plate at least 1/16-inch thick is required to protect the cable.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
5
__________ heating will occur when current carrying conductors of the same circuit are brought through separate holes in a metal box or enclosure.
A) Invective
B) Inductive
C) Convective
D) Conductive
A) Invective
B) Inductive
C) Convective
D) Conductive
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
6
Conductors used in residential wiring can be copper, aluminum, or copper-clad aluminum.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following is not required to be marked on electrical conductors and cables?
A) Maximum rated voltage
B) Proper type letter or letters for the type of cable or conductor
C) AWG size or circular mills
D) The testing laboratory for the cable or conductor
A) Maximum rated voltage
B) Proper type letter or letters for the type of cable or conductor
C) AWG size or circular mills
D) The testing laboratory for the cable or conductor
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
8
Type __________ cable should be used when running a cable underground to an outside pole light.
A) NM-B
B) NM-C
C) UF
D) NM
A) NM-B
B) NM-C
C) UF
D) NM
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
9
A receptacle outlet controlled by a wall switch is permitted to serve as a lighting outlet in kitchens.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
10
Where the opening to an outlet, junction, or switch point box is less than 8 inches in any dimension, each conductor must be long enough to extend at least __________ outside the opening.
A) 3 inches
B) 6 inches
C) 8 inches
D) Far enough to complete the wiring
A) 3 inches
B) 6 inches
C) 8 inches
D) Far enough to complete the wiring
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
11
A short piece of metal raceway is used to provide protection to a cable assembly.According to the NEC, this is permitted even though the metal raceway is not mechanically continuous.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
12
Where device boxes are installed in walls or ceilings with a noncombustible surface, the edge of the box must __________ the wall or ceiling surface.
A) not be set back farther than 1/8 inch from
B) not be set back farther than 1/4 inch from
C) not be set back farther than 1/2 inch from
D) be flush with
A) not be set back farther than 1/8 inch from
B) not be set back farther than 1/4 inch from
C) not be set back farther than 1/2 inch from
D) be flush with
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
13
Where nonmetallic sheathed cable is used with a single gang nonmetallic device box, the cable sheath must extend inside the box not less than __________.
A) 1/16 inch
B) 1/8 inch
C) 1/4 inch
D) 1/2 inch
A) 1/16 inch
B) 1/8 inch
C) 1/4 inch
D) 1/2 inch
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
14
Boxes for floor receptacles must be specifically listed for that purpose and no other box type can be used in a floor installation.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
15
When device boxes are installed in walls or ceilings with a combustible surface such as wood, the edge of the boxes must __________ the finished surface.
A) not be set back farther than 1/8 inch from
B) not be set back farther than 1/4 inch from
C) nor be set back farther than 1/2 inch from
D) be flush with
A) not be set back farther than 1/8 inch from
B) not be set back farther than 1/4 inch from
C) nor be set back farther than 1/2 inch from
D) be flush with
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
16
Sheetrock, a popular building material used to finish off walls and ceilings in residential and commercial construction, is also referred to as wallboard.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
17
Receptacles are not required on a wall directly behind a range, counter-mounted cooking unit, or sink unless there is more than 12 inches of space behind one of these items and the wall.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
18
Which of the following colors is not acceptable for an ungrounded conductor?
A) Brown
B) Yellow
C) Orange
D) Gray
A) Brown
B) Yellow
C) Orange
D) Gray
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
19
The NEC allows Class 2 control wiring to be supported by the raceway that supplies power to the piece of equipment (like a furnace) that the control wiring is associated with.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
20
An electrician discovers that a two-wire cable has been installed instead of a three-wire cable.To remedy the problem, the electrician installs an additional single insulated conductor along with the two-wire cable.This wiring method is acceptable according to the NEC.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
21
Receptacles must be placed to serve the countertop surfaces in a kitchen so that no more than __________ feet are between each receptacle.
A) 2
B) 3
C) 4
D) 6
A) 2
B) 3
C) 4
D) 6
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
22
__________ are long thin strips of wood (or metal) used to make backing surfaces to support the finished surfaces like sheetrock in a room.
A) Furring strips
B) Knockout plugs
C) Deteriorating agents
D) Sill plates
A) Furring strips
B) Knockout plugs
C) Deteriorating agents
D) Sill plates
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
23
Receptacles that are installed to meet NEC Section 210.52 placement requirements are not permitted to be more than __________ feet above the floor.
A) 4.5
B) 5
C) 5.5
D) 6
A) 4.5
B) 5
C) 5.5
D) 6
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
24
The __________ stage is when the raceways, cable, boxes, and other electrical equipment are installed.
A) planning and preparation
B) trim-out
C) troubleshooting
D) rough-in
A) planning and preparation
B) trim-out
C) troubleshooting
D) rough-in
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
25
Where one or more lighting outlet(s) are installed for interior stairways, there must be a wall switch to control the lighting outlet(s) at each floor level and landing, where the stairway between floor levels has __________ risers or more.
A) 6
B) 10
C) 12
D) 15
A) 6
B) 10
C) 12
D) 15
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
26
The required wall receptacle in each bathroom of a dwelling unit must be installed adjacent to, and within __________ of the outside edge of each basin.(General Rule)
A) 8 inches
B) 24 inches
C) 36 inches
D) 6 feet
A) 8 inches
B) 24 inches
C) 36 inches
D) 6 feet
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
27
Boxes that are listed for ceiling suspended paddle fans are permitted to support fans that do not weigh more than __________ pounds.Boxes that can support more than 35 pounds must have the maximum weight marked on the box.
A) 35
B) 45
C) 50
D) 70
A) 35
B) 45
C) 50
D) 70
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
28
A minimum of _________ communications outlet must be installed in all newly constructed dwelling units.
A) one
B) two
C) three
D) four
A) one
B) two
C) three
D) four
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
29
Where cables and raceways are installed less than 1-1/4 inches from the edge of framing members, a metal plate at least ____________________ thick must be installed to protect the cables and raceways.(General Rule)
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
30
Hallways of __________ or more in length must have at least one receptacle outlet.
A) 6 feet
B) 10 feet
C) 12 feet
D) 15 feet
A) 6 feet
B) 10 feet
C) 12 feet
D) 15 feet
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
31
Individual wall spaces of __________ feet or more in width are considered usable for the location of a lamp or appliance, and a receptacle outlet is required.
A) 2
B) 4
C) 6
D) 12
A) 2
B) 4
C) 6
D) 12
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
32
Lighting fixtures installed in a ceiling, weighing no more than __________, are permitted to be supported by outlet boxes.
A) 35 pounds
B) 45 pounds
C) 50 pounds
D) 75 pounds
A) 35 pounds
B) 45 pounds
C) 50 pounds
D) 75 pounds
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
33
In kitchens, a receptacle outlet must be installed at each counter space that is __________ or wider.
A) 6-inch wide
B) 12-inch wide
C) 10-inch wide
D) 24-inch wide
A) 6-inch wide
B) 12-inch wide
C) 10-inch wide
D) 24-inch wide
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
34
Receptacle outlets must be installed on or above, but not more than __________ above the kitchen countertop or work surface.
A) 6 inches
B) 12 inches
C) 20 inches
D) 24 inches
A) 6 inches
B) 12 inches
C) 20 inches
D) 24 inches
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
35
An electrical box must be installed at each conductor splice point, outlet point, switch point, junction point, or termination point where the wiring method is conduit or cable.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
36
Device boxes can support a lighting fixture weighing no more than ________ pounds as long as the fixture is secured to the box with at least two 6-32 screws.
A) 2
B) 6
C) 10
D) 35
A) 2
B) 6
C) 10
D) 35
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
37
In each attached garage, receptacle outlets must be located so that there is at least _____ receptacle outlet in each vehicle bay and not located more than _____ above the floor.
A) one, 5.5 feet
B) two, 6 feet
C) three, 3 feet
D) four, 5 feet
A) one, 5.5 feet
B) two, 6 feet
C) three, 3 feet
D) four, 5 feet
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
38
Receptacles must be installed so that no point measured along the floor line in any wall space is more than __________ feet from a receptacle.
A) 3
B) 6
C) 10
D) 12
A) 3
B) 6
C) 10
D) 12
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
39
A(n)_________ is an entranceway or transitional space from the exterior to the interior of a house.
A) porch
B) foyer
C) annex
D) closet
A) porch
B) foyer
C) annex
D) closet
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
40
At least one receptacle outlet must be installed at each peninsular counter space with a long dimension of __________ or greater and a short dimension of __________ or greater.
A) 12 inches, 24 inches
B) 12 inches, 48 inches
C) 48 inches, 24 inches
D) 24 inches, 12 inches
A) 12 inches, 24 inches
B) 12 inches, 48 inches
C) 48 inches, 24 inches
D) 24 inches, 12 inches
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
41
The term used by electricians to describe the process of installing a residential electrical system is ____________________.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
42
Cables installed in or under metal-corrugated sheet roof decking are required to be installed and supported so there is not less than __________ measured from the lowest surface of the roof decking to the top of the cable or raceway.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
43
Explain when conductors smaller than 14 AWG copper are allowed to be used in residential wiring.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
44
At least ____________________ inches of free conductor, measured from the point in the box where it emerges from its raceway or cable sheath, must be left at each outlet, junction, or switch point for the connection of luminaires or devices.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
45
Explain the NEC requirements for outdoor receptacle placement at a one family dwelling.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
46
Where nonmetallic sheathed cable passes through factory or field punched holes in metal framing members, the cable must be protected by a(n) ____________________.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
47
Describe how a 4 AWG or larger wire is identified as a grounded conductor.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
48
The common piece of electrical equipment that electricians use to insert into any knockout opening that is open and not used is called a _________________________.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
49
When Type NM or Type UF cables are used, the outside sheathing of the cable must extend at least 1/4 inch (6 mm) inside the box and beyond any cable clamp.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck