Deck 22: Commercial Utility Interactive Photovoltaic Systems

Full screen (f)
exit full mode
Question
Using the and module frame grounding location specified in the module installation instructions is the only way to ensure connection integrityfor the life of the system.

A)ground-fault current
B)aluminum frames
C)combiner boxes
D)grounding hardware
Use Space or
up arrow
down arrow
to flip the card.
Question
The NEC requires all utility interactive inverters to be listed to UL 1741.Please explain the two key requirements of the standard.
Question
Grounded conductors, whether dc or ac, must be identified with white or insulation in accordance with NEC 200.6.

A)orange
B)gray
C)green
D)black
Question
How can the photovoltaic effect can be put to practical use in a commercial building?
Question
Commercial utility interactive PV system may require a designer to specify the supply-side connection permitted by NEC 705.12(A).

A)size
B)height
C)weight
D)width
Question
Ampacity correction for temperature must be considered for both the dc and ac system conductors.

A)ambient
B)minimum
C)maximum
D)below normal
Question
A -line diagram is an electrical schematic diagram for the utility interactive PV system.

A)single
B)double
C)split
D)reduced
Question
The most common material used today for production of photovoltaic cells is .

A)crystalline silicon
B)magnesium phosphate
C)synthetic silicon
D)potassium chloride
Question
What has the 2011 NEC required for arc-fault protection, and what are its three functions?
Question
What is a single-line diagram, what is its purpose, and what information should it include?
Question
A ground-mounted photovoltaic module array for a commercial building may be constructed so that it can be used as ____.

A)a storage area
B)a covered walkway
C)covered vehicle parking
D)a break area for building occupants
Question
The general procedure for inverter startup is to check and current levels from the source (modules) to inverter closing disconnects as needed to accomplish this.

A)ampacity
B)wattage
C)voltage
D)conduction potential
Question
The equipment that converts the direct current produced by modules into an alternating current (ac) output is known as a(n) ____.

A)reverter
B)converter
C)inverter
D)diverter
Question
modules are the basic building block of a utility interactive photovoltaic system.

A)Semiconductor
B)Photovoltaic
C)Solar
D)Aluminum
Question
The installation of utility interactive solar photovoltaic systems has accelerated in recent years due to energy conservation and concerns.

A)environmental
B)electrical
C)solar
D)semiconductor
Question
The maximum dc source current is defined by NEC 690.8(A) as the sum of parallel module rated short circuit currents multiplied by percent.

A)110
B)125
C)150
D)200
Question
A(n) is simply a collection of modules that form a complete photovoltaic generating unit.

A)generation
B)combiner
C)modulation
D)array
Question
Describe the requirement for a grounding electrode system for a utility interactive photovoltaic installation.
Question
The plans for commercial PV projects usually have to be submitted to the for review and comment prior to issuance of a permit.

A)AHJ
B)CFP
C)PVJ
D)BHO
Question
NEC 705.10 requires that a(n) that indicates all interconnected power sources for the premises be installed at the service and the location(s) of the power production source(s).

A)removable label
B)sign
C)instruction sheet
D)permanent plaque or directory
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Commercial Utility Interactive Photovoltaic Systems
1
Using the and module frame grounding location specified in the module installation instructions is the only way to ensure connection integrityfor the life of the system.

A)ground-fault current
B)aluminum frames
C)combiner boxes
D)grounding hardware
D
2
The NEC requires all utility interactive inverters to be listed to UL 1741.Please explain the two key requirements of the standard.
The NEC requires all utility-interactive inverters to be listed to UL 1741.PV system designers and installers should be aware of two key requirements of the standard.The first is known as anti- islanding.Utility-interactive inverters are required to automatically turn off when utility power is lost.This prevents an inverter from feeding electricity back into the utility electrical grid, which would be extremely dangerous for utility workers.Remember that the 240 volts produced by an inverter can produce 12,000 volts or more on the primary side of utility transformers if the inverter were allowed to back-feed the utility system.In effect, the utility transformer would be operating
as a step-up transformer.Another important requirement of UL 1741 is for dc ground-fault protection (GFP).Ground faults in PV source circuits (array) do not result in the high fault currents produced by utility electrical services.Photovoltaic modules are a current-limited source.Short- circuit current from a module is slightly higher than normal module output to the inverter, but not enough to open an overcurrent device (fuse or circuit breaker).Ground-fault current will flow through bonded exposed metallic structures and raceways to the inverter and then back to the source (modules).
3
Grounded conductors, whether dc or ac, must be identified with white or insulation in accordance with NEC 200.6.

A)orange
B)gray
C)green
D)black
B
4
How can the photovoltaic effect can be put to practical use in a commercial building?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Commercial utility interactive PV system may require a designer to specify the supply-side connection permitted by NEC 705.12(A).

A)size
B)height
C)weight
D)width
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Ampacity correction for temperature must be considered for both the dc and ac system conductors.

A)ambient
B)minimum
C)maximum
D)below normal
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
A -line diagram is an electrical schematic diagram for the utility interactive PV system.

A)single
B)double
C)split
D)reduced
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
The most common material used today for production of photovoltaic cells is .

A)crystalline silicon
B)magnesium phosphate
C)synthetic silicon
D)potassium chloride
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
What has the 2011 NEC required for arc-fault protection, and what are its three functions?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
What is a single-line diagram, what is its purpose, and what information should it include?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
A ground-mounted photovoltaic module array for a commercial building may be constructed so that it can be used as ____.

A)a storage area
B)a covered walkway
C)covered vehicle parking
D)a break area for building occupants
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The general procedure for inverter startup is to check and current levels from the source (modules) to inverter closing disconnects as needed to accomplish this.

A)ampacity
B)wattage
C)voltage
D)conduction potential
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The equipment that converts the direct current produced by modules into an alternating current (ac) output is known as a(n) ____.

A)reverter
B)converter
C)inverter
D)diverter
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
modules are the basic building block of a utility interactive photovoltaic system.

A)Semiconductor
B)Photovoltaic
C)Solar
D)Aluminum
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
The installation of utility interactive solar photovoltaic systems has accelerated in recent years due to energy conservation and concerns.

A)environmental
B)electrical
C)solar
D)semiconductor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
The maximum dc source current is defined by NEC 690.8(A) as the sum of parallel module rated short circuit currents multiplied by percent.

A)110
B)125
C)150
D)200
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
A(n) is simply a collection of modules that form a complete photovoltaic generating unit.

A)generation
B)combiner
C)modulation
D)array
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Describe the requirement for a grounding electrode system for a utility interactive photovoltaic installation.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
The plans for commercial PV projects usually have to be submitted to the for review and comment prior to issuance of a permit.

A)AHJ
B)CFP
C)PVJ
D)BHO
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
NEC 705.10 requires that a(n) that indicates all interconnected power sources for the premises be installed at the service and the location(s) of the power production source(s).

A)removable label
B)sign
C)instruction sheet
D)permanent plaque or directory
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.