1
When calculating appliance load in a one-family dwelling, ____ should be used.
A) demand factors
B) compliance ratings
C) BTUs
D) nameplate ratings
A) demand factors
B) compliance ratings
C) BTUs
D) nameplate ratings
D
2
In a multiple-occupancy building, each occupant must have access to the unit's ____.
A) main feeder line
B) service meter
C) fuse box
D) service disconnecting means
A) main feeder line
B) service meter
C) fuse box
D) service disconnecting means
D
3
All 15- or 20-ampere general-use receptacle outlets (except for small-appliance and laundry) are considered part of the ____.
A) main branch
B) central service
C) general lighting load
D) general service
A) main branch
B) central service
C) general lighting load
D) general service
C
4
A load calculation on an individual unit in a multifamily dwelling must be calculated in accordance with one of the ____ methods.
A) multi-family dwelling load-calculation
B) multi-family dwelling load-calculation divided by the number of units per floor
C) one-family dwelling load-calculation
D) one-family dwelling load-calculation multiplied by the number of units per floor
A) multi-family dwelling load-calculation
B) multi-family dwelling load-calculation divided by the number of units per floor
C) one-family dwelling load-calculation
D) one-family dwelling load-calculation multiplied by the number of units per floor
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
5
The term appliance designates ____ equipment installed as a unit to perform specific function.
A) laundry
B) kitchen
C) compliance
D) utilization
A) laundry
B) kitchen
C) compliance
D) utilization
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
6
Each laundry branch circuit is calculated at no less than ____ volt-amperes.
A) 1000
B) 1100
C) 1200
D) 1500
A) 1000
B) 1100
C) 1200
D) 1500
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
7
No more than ____ disconnects per service can be grouped in one location.
A) two
B) four
C) six
D) eight
A) two
B) four
C) six
D) eight
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
8
A clothes dryer neutral load on a feeder is calculated at ____%
A) 50
B) 60
C) 70
D) 80
A) 50
B) 60
C) 70
D) 80
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
9
The service disconnecting means for a one-family dwelling load calculation must have a rating of at least ____.
A) the calculated load
B) the load for a single unit
C) one quarter the total load
D) one half the total load
A) the calculated load
B) the load for a single unit
C) one quarter the total load
D) one half the total load
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
10
When calculating load, the ____ can be omitted, as long as they are never energized simultaneously.
A) smallest branch circuit
B) smaller of two (or more) noncoincident loads
C) branch circuit containing the kitchen and laundry room
D) larger of two (or more) branch circuits
A) smallest branch circuit
B) smaller of two (or more) noncoincident loads
C) branch circuit containing the kitchen and laundry room
D) larger of two (or more) branch circuits
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
11
Electric heating loads (including associated motors) are calculated at ____% of the total connected load.
A) 75
B) 100
C) 125
D) 150
A) 75
B) 100
C) 125
D) 150
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
12
When calculating load, household cooking appliances rated over ____ kW should be included.
A) 1.25
B) 1.50
C) 1.75
D) 10
A) 1.25
B) 1.50
C) 1.75
D) 10
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
13
A heat pump with supplementary heat is ____.
A) considered a coincident load
B) not considered a noncoincident load
C) sometimes considered a coincident load
D) sometimes considered a noncoincident load
A) considered a coincident load
B) not considered a noncoincident load
C) sometimes considered a coincident load
D) sometimes considered a noncoincident load
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
14
Derating is allowed for a total of four (or more) ____.
A) fastened-in-place appliances
B) branch circuits
C) kitchen receptacles
D) basement receptacles
A) fastened-in-place appliances
B) branch circuits
C) kitchen receptacles
D) basement receptacles