Deck 14: Services, Feeders, and Equipment

Full screen (f)
exit full mode
Question
According to the NEC , live parts of electric equipment operating at 50 volts or more shall be guarded against ____ by approved enclosures.

A) water damage
B) overvoltage
C) accidental contact
D) phase transformations
Use Space or
up arrow
down arrow
to flip the card.
Question
Overcurrent protection for transformers over ____ volts, nominal, is required.

A) 300
B) 500
C) 600
D) 1000
Question
Where ungrounded conductors are increased in size from the minimum size that has sufficient ampacity for the intended installation, wire-type, equipment grounding conductors (where installed) shall be increased in size ____, according to the circular mil area of the ungrounded conductors.

A) proportionately
B) inversely
C) directly
D) indirectly
Question
The ____ phase must be that phase having the higher voltage to ground on 3-phase, 4-wire, deltaconnected systems.

A) A
B) C
C) D
D) B
Question
According to the NEC , where a panelboard is supplied through a transformer, the overcurrent protection required by 408.36 shall be located on the ____ side of the transformer.

A) top
B) bottom
C) primary
D) secondary
Question
The connection between the grounded circuit conductor (neutral) and the equipment grounding conductor at the service is the ____.

A) main switching lead
B) main bonding jumper
C) central lead
D) transverse bridge
Question
A ____ is a large single panel, frame, or assembly of panels with front- or rear-mounted switches, protective devices (overcurrent, etc.), buses, and, usually, instruments.

A) panelboard
B) switchboard
C) circuit cabinet
D) panel cabinet
Question
One access means to working spaces is permitted where the location provides ____.

A) a continuous and unobstructed exit
B) adequate sprinkler coverage
C) balcony exits
D) adequate overhead clearance
Question
Equipment rated ____ amperes (or more) and over 6 ft (1.8 m) wide containing overcurrent devices, switching devices, or control are governed by specific entrance and egress requirements.

A) 700
B) 1000
C) 1100
D) 1200
Question
The alternating current phase arrangement on 3-phase busses are ____ from front to back, top to bottom, or left to right, as viewed from the front of the switchboard, switchgear, or panelboard.

A) A, B, C
B) C, B, A
C) B, C, A
D) A, C, B
Question
Service equipment in other than dwelling units shall be legibly marked in the field with the ____.

A) average impedance
B) minimum current
C) maximum available fault current
D) maximum average current
Question
No secondary overcurrent protection is required for certain transformers 1000 volts, nominal, or less with currents of at least 9 amperes and a maximum primary overcurrent protection of ____.

A) 75%
B) 100%
C) 125%
D) 150%
Question
Vertical wiring clearances apply to ____.

A) commercial services
B) residential services
C) all electrical feeder and service installations
D) dwellings over six stories
Question
Where the ungrounded supply conductors are larger than 1100 kcmil copper or 1750 kcmil aluminum, the supply-side bonding jumper shall have an area not less than ____ of the area of the largest set of ungrounded supply conductors or equivalent area for parallel supply conductors.

A) 10 1/2%
B) 12 1/2%
C) 15 1/2%
D) 18 1/2%
Question
Where rear access is required to work on nonelectrical parts at the back of enclosed equipment, a minimum working space of ____. horizontally is required.

A) 20 in
B) 30 in
C) 36 in
D) 40 in
Question
A ____ minimum vertical clearance is required above finished grade for sidewalks, or from any platform or projection from which overhead conductors (of 150 volts, or less, to ground) might be reached.

A) 9-ft
B) 10-ft
C) 11-ft
D) 12-ft
Question
A structural ceiling may not ____.

A) contain any wiring
B) contain any lighting
C) be a suspended or drop type
D) contain ductwork
Question
All panelboards shall have a rating not less than the ____ required for the load calculated in accordance with Part III, IV, or V of Article 220.

A) minimum feeder capacity
B) maximum feeder capacity
C) 50 % of maximum feeder capacity
D) 50 % of minimum feeder capacity
Question
A drip loop's lowest point has a minimum vertical clearance of ____.

A) 9 ft
B) 10 ft
C) 11 ft
D) 12 ft
Question
Ground-fault protection that functions to open the service disconnect will afford no protection from faults on the ____ of the protective element.

A) circuit side
B) panel box side
C) underside
D) line side
Question
Live generator parts operating at more than ____ volts to ground shall not be exposed to accidental contact by unqualified persons.

A) 25
B) 50
C) 75
D) 100
Question
The maximum rating for an overcurrent protection on a primary unit is ____.

A) 125%
B) 250%
C) 300%
D) 350%
Question
All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to a grounding electrode shall be ____.

A) painted
B) waterproof
C) accessible
D) lubricated
Question
Premises wiring (system) is defined as ____, including power, lighting, control, and signal circuit wiring together with all their associated hardware, fittings, and wiring devices, both permanently and temporarily installed.

A) interior and exterior wiring
B) interior wiring
C) exterior wiring
D) main service wiring
Question
A system that supplies a ____ and is derived from a transformer rated no more than 1000 volt-amperes does not require a grounding electrode conductor.

A) Class A, EE, AE circuit
B) main branch circuit
C) secondary circuit
D) Class 1, 2, or 3 circuit
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 14: Services, Feeders, and Equipment
1
According to the NEC , live parts of electric equipment operating at 50 volts or more shall be guarded against ____ by approved enclosures.

A) water damage
B) overvoltage
C) accidental contact
D) phase transformations
accidental contact
2
Overcurrent protection for transformers over ____ volts, nominal, is required.

A) 300
B) 500
C) 600
D) 1000
D
3
Where ungrounded conductors are increased in size from the minimum size that has sufficient ampacity for the intended installation, wire-type, equipment grounding conductors (where installed) shall be increased in size ____, according to the circular mil area of the ungrounded conductors.

A) proportionately
B) inversely
C) directly
D) indirectly
A
4
The ____ phase must be that phase having the higher voltage to ground on 3-phase, 4-wire, deltaconnected systems.

A) A
B) C
C) D
D) B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
According to the NEC , where a panelboard is supplied through a transformer, the overcurrent protection required by 408.36 shall be located on the ____ side of the transformer.

A) top
B) bottom
C) primary
D) secondary
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
The connection between the grounded circuit conductor (neutral) and the equipment grounding conductor at the service is the ____.

A) main switching lead
B) main bonding jumper
C) central lead
D) transverse bridge
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
A ____ is a large single panel, frame, or assembly of panels with front- or rear-mounted switches, protective devices (overcurrent, etc.), buses, and, usually, instruments.

A) panelboard
B) switchboard
C) circuit cabinet
D) panel cabinet
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
One access means to working spaces is permitted where the location provides ____.

A) a continuous and unobstructed exit
B) adequate sprinkler coverage
C) balcony exits
D) adequate overhead clearance
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
Equipment rated ____ amperes (or more) and over 6 ft (1.8 m) wide containing overcurrent devices, switching devices, or control are governed by specific entrance and egress requirements.

A) 700
B) 1000
C) 1100
D) 1200
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
The alternating current phase arrangement on 3-phase busses are ____ from front to back, top to bottom, or left to right, as viewed from the front of the switchboard, switchgear, or panelboard.

A) A, B, C
B) C, B, A
C) B, C, A
D) A, C, B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Service equipment in other than dwelling units shall be legibly marked in the field with the ____.

A) average impedance
B) minimum current
C) maximum available fault current
D) maximum average current
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
No secondary overcurrent protection is required for certain transformers 1000 volts, nominal, or less with currents of at least 9 amperes and a maximum primary overcurrent protection of ____.

A) 75%
B) 100%
C) 125%
D) 150%
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Vertical wiring clearances apply to ____.

A) commercial services
B) residential services
C) all electrical feeder and service installations
D) dwellings over six stories
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Where the ungrounded supply conductors are larger than 1100 kcmil copper or 1750 kcmil aluminum, the supply-side bonding jumper shall have an area not less than ____ of the area of the largest set of ungrounded supply conductors or equivalent area for parallel supply conductors.

A) 10 1/2%
B) 12 1/2%
C) 15 1/2%
D) 18 1/2%
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Where rear access is required to work on nonelectrical parts at the back of enclosed equipment, a minimum working space of ____. horizontally is required.

A) 20 in
B) 30 in
C) 36 in
D) 40 in
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
A ____ minimum vertical clearance is required above finished grade for sidewalks, or from any platform or projection from which overhead conductors (of 150 volts, or less, to ground) might be reached.

A) 9-ft
B) 10-ft
C) 11-ft
D) 12-ft
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
A structural ceiling may not ____.

A) contain any wiring
B) contain any lighting
C) be a suspended or drop type
D) contain ductwork
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
All panelboards shall have a rating not less than the ____ required for the load calculated in accordance with Part III, IV, or V of Article 220.

A) minimum feeder capacity
B) maximum feeder capacity
C) 50 % of maximum feeder capacity
D) 50 % of minimum feeder capacity
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
A drip loop's lowest point has a minimum vertical clearance of ____.

A) 9 ft
B) 10 ft
C) 11 ft
D) 12 ft
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
Ground-fault protection that functions to open the service disconnect will afford no protection from faults on the ____ of the protective element.

A) circuit side
B) panel box side
C) underside
D) line side
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Live generator parts operating at more than ____ volts to ground shall not be exposed to accidental contact by unqualified persons.

A) 25
B) 50
C) 75
D) 100
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
The maximum rating for an overcurrent protection on a primary unit is ____.

A) 125%
B) 250%
C) 300%
D) 350%
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to a grounding electrode shall be ____.

A) painted
B) waterproof
C) accessible
D) lubricated
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Premises wiring (system) is defined as ____, including power, lighting, control, and signal circuit wiring together with all their associated hardware, fittings, and wiring devices, both permanently and temporarily installed.

A) interior and exterior wiring
B) interior wiring
C) exterior wiring
D) main service wiring
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
A system that supplies a ____ and is derived from a transformer rated no more than 1000 volt-amperes does not require a grounding electrode conductor.

A) Class A, EE, AE circuit
B) main branch circuit
C) secondary circuit
D) Class 1, 2, or 3 circuit
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.