Deck 7: Specific Provisions

Full screen (f)
exit full mode
Question
GFCI protection is required for receptacles installed to serve ____.

A) wall counter space
B) receptacles installed along a wall
C) kitchen countertops
D) inside cabinet receptacles
Use Space or
up arrow
down arrow
to flip the card.
Question
Receptacles, unless listed as receptacle assemblies for countertop applications, shall not be installed ____ in countertops or similar work surfaces.

A) in a wall mount
B) in a face-up position
C) above a sink
D) adjacent to a sink
Question
____ should not be connected with flexible cords.

A) Water heaters
B) Small appliances
C) Dishwashers
D) Garbage disposals
Question
At least one wall switch-controlled lighting outlet is required to provide illumination on the ____.

A) exterior side of an outside entrance or exit with grade-level access
B) interior side of an outside entrance or exit with grade-level access
C) adjacent to a vehicle garage door
D) adjacent to exterior stairs
Question
Laundry equipment receptacles ____.

A) are not permitted in garage spaces
B) shall not be counted as required garage receptacles
C) do not require GFCI protection
D) shall be counted as a single receptacle
Question
The bathtub zone measures _____ from the top of the bathtub rim or shower stall threshold and includes the space directly over the tub.

A) 3 ft horizontally and 8 ft vertically
B) 4 ft horizontally and 8 ft vertically
C) 3 ft horizontally and 6 ft vertically
D) 6 ft horizontally and 10 ft vertically
Question
A clothes dryer outlet must have ____ and an equipment grounding conductor.

A) 25-ampere dedicated circuit
B) an accessible circuit breaker
C) two adjacent receptacles
D) an insulated grounded (neutral) conductor
Question
____ luminaire types are not permitted in a clothes closet.

A) Recessed incandescent luminaire
B) Pendant luminaires or lampholders
C) Surface-mounted fluorescent
D) Light-emitting diode
Question
A(n) ____ is permitted on a small-appliance branch circuit.

A) dedicated clock outlet
B) hood fan
C) outdoor receptacle
D) lighting outlet
Question
All receptacles installed to serve kitchen countertop surfaces shall have _____.

A) ARCI protection
B) GFCI protection
C) a UL listing
D) a 20 ampere rating
Question
The bathtub zone refers to an area in which ____.

A) all luminaires or cord connected appliance receptacles must be grounded to plumbing
B) recessed lights are not permitted
C) exhaust fans are not permitted
D) no parts of cord-connected luminaires, and ceiling-suspended (paddle) fans are permitted
Question
A(n) ____ or an accessible plug and receptacle can serve as the disconnecting means.

A) suitable ground
B) fuse box or circuit breaker
C) accessible separable connector
D) an approved power strip
Question
You can use the nameplate rating to determine the branch-circuit conductor size and the overcurrent protection for ____.

A) a dishwashing unit
B) one counter-mounted cooking unit
C) a refrigerator
D) an appliance branch circuit
Question
Tap conductors from a 50-ampere branch circuit must have an ampacity of at least ____ and not less than the ampacity of the individual unit served.

A) 10
B) 20
C) 30
D) 50
Question
Interior stairways of ____ or more risers (steps) shall have a wall switch located at each floor level and landing level that includes an entryway.

A) six
B) seven
C) ten
D) twelve
Question
GFCI protection for personnel is required for every ____ receptacle located in the bathroom area.

A) 125-volt, single-phase 20- and 25-ampere
B) 112-volt, single-phase 15-ampere
C) 112-volt, single-phase 20-ampere
D) 125-volt, single-phase 15- and 20-ampere
Question
Branch circuits in kitchens should be ____-ampere circuits.

A) 15
B) 20
C) 25
D) 40
Question
A disconnecting means is not required for appliances installed in a basement if ____.

A) the branch-circuit is rated for a load of 20-amperes
B) there is a branch-circuit switch or circuit breaker can be locked in the open (on) position
C) the branch-circuit switch or circuit breaker is within 50 ft and can be seen while working on the appliance
D) the branch-circuit contains three or more branches
Question
A branch circuit providing power to bathroom receptacles shall not provide power to ____.

A) other bathroom receptacles
B) lighting
C) any receptacle or lighting outside of bathrooms
D) exhaust fans
Question
A detached garage with electrical power must have ____.

A) a branch circuit rated for a 20-ampere load
B) at least one wall switch-controlled lighting outlet
C) a separate circuit breaker
D) at least one receptacle for each 3 ft of wall space
Question
Laundry receptacle outlet(s) must be fed from a ____ branch circuit.

A) 15-ampere
B) 20-ampere
C) 30-ampere
D) 40-ampere
Question
A crawl space or underfloor space must contain ____.

A) at least 4 ft of head clearance
B) dedicated HVAC branch circuits
C) a disconnecting means for HVAC equipment
D) access to HVAC equipment
Question
A receptacle outlet installed for a specific appliance, such as laundry equipment, shall be installed within ____ of the intended location of the appliance.

A) 3 ft
B) 6 ft
C) 8 ft
D) 9 ft
Question
A ____ rated receptacle outlet shall be installed at an accessible location for the servicing of equipment within a crawl space.

A) 125-volt, single-phase, 15- or 20-ampere
B) 112-volt, single-phase, 15- or 20-ampere
C) 112-volt, dual-phase, 15- or 20-ampere
D) 125-volt, dual-phase, 15- or 20-ampere
Question
Attic spaces used for storage or containing equipment that may require servicing ____.

A) do not require a lighting switch
B) require one lighting outlet
C) do not require a lighting outlet
D) require GFCI protection on receptacles
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 7: Specific Provisions
1
GFCI protection is required for receptacles installed to serve ____.

A) wall counter space
B) receptacles installed along a wall
C) kitchen countertops
D) inside cabinet receptacles
C
2
Receptacles, unless listed as receptacle assemblies for countertop applications, shall not be installed ____ in countertops or similar work surfaces.

A) in a wall mount
B) in a face-up position
C) above a sink
D) adjacent to a sink
B
3
____ should not be connected with flexible cords.

A) Water heaters
B) Small appliances
C) Dishwashers
D) Garbage disposals
A
4
At least one wall switch-controlled lighting outlet is required to provide illumination on the ____.

A) exterior side of an outside entrance or exit with grade-level access
B) interior side of an outside entrance or exit with grade-level access
C) adjacent to a vehicle garage door
D) adjacent to exterior stairs
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
Laundry equipment receptacles ____.

A) are not permitted in garage spaces
B) shall not be counted as required garage receptacles
C) do not require GFCI protection
D) shall be counted as a single receptacle
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
The bathtub zone measures _____ from the top of the bathtub rim or shower stall threshold and includes the space directly over the tub.

A) 3 ft horizontally and 8 ft vertically
B) 4 ft horizontally and 8 ft vertically
C) 3 ft horizontally and 6 ft vertically
D) 6 ft horizontally and 10 ft vertically
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
A clothes dryer outlet must have ____ and an equipment grounding conductor.

A) 25-ampere dedicated circuit
B) an accessible circuit breaker
C) two adjacent receptacles
D) an insulated grounded (neutral) conductor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
____ luminaire types are not permitted in a clothes closet.

A) Recessed incandescent luminaire
B) Pendant luminaires or lampholders
C) Surface-mounted fluorescent
D) Light-emitting diode
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
A(n) ____ is permitted on a small-appliance branch circuit.

A) dedicated clock outlet
B) hood fan
C) outdoor receptacle
D) lighting outlet
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
All receptacles installed to serve kitchen countertop surfaces shall have _____.

A) ARCI protection
B) GFCI protection
C) a UL listing
D) a 20 ampere rating
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
The bathtub zone refers to an area in which ____.

A) all luminaires or cord connected appliance receptacles must be grounded to plumbing
B) recessed lights are not permitted
C) exhaust fans are not permitted
D) no parts of cord-connected luminaires, and ceiling-suspended (paddle) fans are permitted
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
A(n) ____ or an accessible plug and receptacle can serve as the disconnecting means.

A) suitable ground
B) fuse box or circuit breaker
C) accessible separable connector
D) an approved power strip
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
You can use the nameplate rating to determine the branch-circuit conductor size and the overcurrent protection for ____.

A) a dishwashing unit
B) one counter-mounted cooking unit
C) a refrigerator
D) an appliance branch circuit
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Tap conductors from a 50-ampere branch circuit must have an ampacity of at least ____ and not less than the ampacity of the individual unit served.

A) 10
B) 20
C) 30
D) 50
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Interior stairways of ____ or more risers (steps) shall have a wall switch located at each floor level and landing level that includes an entryway.

A) six
B) seven
C) ten
D) twelve
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
GFCI protection for personnel is required for every ____ receptacle located in the bathroom area.

A) 125-volt, single-phase 20- and 25-ampere
B) 112-volt, single-phase 15-ampere
C) 112-volt, single-phase 20-ampere
D) 125-volt, single-phase 15- and 20-ampere
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Branch circuits in kitchens should be ____-ampere circuits.

A) 15
B) 20
C) 25
D) 40
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
A disconnecting means is not required for appliances installed in a basement if ____.

A) the branch-circuit is rated for a load of 20-amperes
B) there is a branch-circuit switch or circuit breaker can be locked in the open (on) position
C) the branch-circuit switch or circuit breaker is within 50 ft and can be seen while working on the appliance
D) the branch-circuit contains three or more branches
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
A branch circuit providing power to bathroom receptacles shall not provide power to ____.

A) other bathroom receptacles
B) lighting
C) any receptacle or lighting outside of bathrooms
D) exhaust fans
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
A detached garage with electrical power must have ____.

A) a branch circuit rated for a 20-ampere load
B) at least one wall switch-controlled lighting outlet
C) a separate circuit breaker
D) at least one receptacle for each 3 ft of wall space
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Laundry receptacle outlet(s) must be fed from a ____ branch circuit.

A) 15-ampere
B) 20-ampere
C) 30-ampere
D) 40-ampere
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
A crawl space or underfloor space must contain ____.

A) at least 4 ft of head clearance
B) dedicated HVAC branch circuits
C) a disconnecting means for HVAC equipment
D) access to HVAC equipment
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
A receptacle outlet installed for a specific appliance, such as laundry equipment, shall be installed within ____ of the intended location of the appliance.

A) 3 ft
B) 6 ft
C) 8 ft
D) 9 ft
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
A ____ rated receptacle outlet shall be installed at an accessible location for the servicing of equipment within a crawl space.

A) 125-volt, single-phase, 15- or 20-ampere
B) 112-volt, single-phase, 15- or 20-ampere
C) 112-volt, dual-phase, 15- or 20-ampere
D) 125-volt, dual-phase, 15- or 20-ampere
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Attic spaces used for storage or containing equipment that may require servicing ____.

A) do not require a lighting switch
B) require one lighting outlet
C) do not require a lighting outlet
D) require GFCI protection on receptacles
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.