Deck 9: Fire Alarm Systems and National Electrical Code Article 760

Full screen (f)
exit full mode
Question
Heat detectors are considered to be life-safety devices.
Use Space or
up arrow
down arrow
to flip the card.
Question
Indicator devices are considered output devices from the point of view of the control unit.
Question
The fire alarm annunciator panel, monitors all input sensors and initiating devices.
Question
Spacing of smoke detectors on flat surfaces can be a distance of up to _________.

A) 10ft.
B) 30ft.
C) 50ft.
D) 100ft.
Question
Duct detectors are installed ____________.

A) As a substitute for area smoke detectors
B) Next to fresh air returns
C) In all residential locations
D) As a means of shutting down airflow when smoke is detected
Question
End of line devices are required by addressable fire alarm systems.
Question
Single conductor sizes for a power-limited fire alarm circuit cannot be smaller than ____________.

A) 16 AWG
B) 18 AWG
C) 22 AWG
D) 26 AWG
Question
Carbon monoxide detectors are required in all _________.

A) Installations
B) Industrial installations
C) Commercial Installations
D) Residential Installation
Question
Heat detectors are a suitable substitute for smoke detectors.
Question
Emergency telephone must be part of the main telephone system.
Question
Survivability requires a minimum rating of _________ to ensure the functional use of the system during a fire.

A) 1 hour
B) 1.5 hours
C) 2 hours
D) 4 hours
Question
Audible alarm indicators, for commercial spaces, must output a minimum level of _____dB at 10ft. and be _______dB greater than the ambient noise level.

A) 60dB, 6dB
B) 60dB, 15dB
C) 75dB, 15dB
D) 85dB, 15dB
Question
How can the number of devices on an analog addressable circuit and the overall distance requirements from the control panel to the farthest device in the loop be determined ?

A) It is determined by the manufacturer
B) By using end of line devices
C) By calculating the high-speed data requirements
D) By calculating the total current in the loop
Question
Life safety is the primary goal of a fire alarm system.
Question
Fire alarm systems, classified for residential use, cannot be used in commercial space s.
Question
Class A circuits are four wire circuits that do not use end of line devices.
Question
Fire alarm circuits must be clearly labeled at every junction and terminal connection.
Question
What is not a common output indicator for a control panel?

A) Normal
B) Alarm
C) Standby
D) Trouble
Question
The power source for a nonpower-limited fire alarm system cannot output voltages greater than ________

A) 150V
B) 300V
C) 600V
D) 1000V
Question
To ensure survivability, the type of cable required is _________.

A) MI or CI cable
B) Plenum cable
C) Multipurpose cable
D) Class 1 rated cable
Question
A device that detects visible or invisible particles of combustion is a _______.

A) Heat alarm
B) Heat detector
C) Smoke detector
D) Thermistors
Question
What type of smoke detector is most sensitive to particles smaller than 1µm?

A) Air sampling detector
B) Projected beam detector
C) Photoelectric detector
D) Ionization detector
Question
Voltage ratings for power-limited fire alarm circuit conductors must be rated to __________.

A) 150V
B) 300V
C) 600V
D) 1000V
Question
What statement about central station fire alarm systems is true?

A) Are owned and operated by the property owner of the protected premise
B) The central station must be located in the same state as the protected premise
C) The central station must be listed and approved by a recognized testing agency and the AHJ
D) Central stations will only provide service to individual clients
Question
What type of detector technology is nonrestorable?

A) Thermopiles
B) Temperature sensitive resistors
C) Fusible links
D) Thermistors
Question
Maximum allowable ceiling temperatures are typically _________ less than the temperature rating of the heat detector.

A) 1 F
B) 5 F
C) 10 F
D) 20 F
Question
The power source for a power-limited fire alarm system cannot output voltages greater than ________

A) 150V
B) 300V
C) 600V
D) 1000V
Question
What type of heat detector responds to shifting temperatures that vary excessively beyond a predetermined value?

A) Rate-of-rise
B) Rate compensation
C) Fixed temperature
D) Spot detector
Question
What statement about line seizure is not true?

A) Achieved through an RJ-31X connector
B) The house phone will continue to operate
C) Cellular phone may be used as a backup
D) Gives the DACT priority access to the phone line
Question
The Class B system, for initiating devices, connects through a two-wire circuit and _________.

A) Does not use an end of line device
B) Uses an end of line device
C) Is an outdated system no longer used in the United States
D) Uses a series limiting resistor
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/30
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 9: Fire Alarm Systems and National Electrical Code Article 760
1
Heat detectors are considered to be life-safety devices.
False
2
Indicator devices are considered output devices from the point of view of the control unit.
True
3
The fire alarm annunciator panel, monitors all input sensors and initiating devices.
False
4
Spacing of smoke detectors on flat surfaces can be a distance of up to _________.

A) 10ft.
B) 30ft.
C) 50ft.
D) 100ft.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
5
Duct detectors are installed ____________.

A) As a substitute for area smoke detectors
B) Next to fresh air returns
C) In all residential locations
D) As a means of shutting down airflow when smoke is detected
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
6
End of line devices are required by addressable fire alarm systems.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
7
Single conductor sizes for a power-limited fire alarm circuit cannot be smaller than ____________.

A) 16 AWG
B) 18 AWG
C) 22 AWG
D) 26 AWG
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
8
Carbon monoxide detectors are required in all _________.

A) Installations
B) Industrial installations
C) Commercial Installations
D) Residential Installation
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
9
Heat detectors are a suitable substitute for smoke detectors.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
10
Emergency telephone must be part of the main telephone system.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
11
Survivability requires a minimum rating of _________ to ensure the functional use of the system during a fire.

A) 1 hour
B) 1.5 hours
C) 2 hours
D) 4 hours
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
12
Audible alarm indicators, for commercial spaces, must output a minimum level of _____dB at 10ft. and be _______dB greater than the ambient noise level.

A) 60dB, 6dB
B) 60dB, 15dB
C) 75dB, 15dB
D) 85dB, 15dB
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
13
How can the number of devices on an analog addressable circuit and the overall distance requirements from the control panel to the farthest device in the loop be determined ?

A) It is determined by the manufacturer
B) By using end of line devices
C) By calculating the high-speed data requirements
D) By calculating the total current in the loop
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
14
Life safety is the primary goal of a fire alarm system.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
15
Fire alarm systems, classified for residential use, cannot be used in commercial space s.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
16
Class A circuits are four wire circuits that do not use end of line devices.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
17
Fire alarm circuits must be clearly labeled at every junction and terminal connection.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
18
What is not a common output indicator for a control panel?

A) Normal
B) Alarm
C) Standby
D) Trouble
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
19
The power source for a nonpower-limited fire alarm system cannot output voltages greater than ________

A) 150V
B) 300V
C) 600V
D) 1000V
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
20
To ensure survivability, the type of cable required is _________.

A) MI or CI cable
B) Plenum cable
C) Multipurpose cable
D) Class 1 rated cable
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
21
A device that detects visible or invisible particles of combustion is a _______.

A) Heat alarm
B) Heat detector
C) Smoke detector
D) Thermistors
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
22
What type of smoke detector is most sensitive to particles smaller than 1µm?

A) Air sampling detector
B) Projected beam detector
C) Photoelectric detector
D) Ionization detector
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
23
Voltage ratings for power-limited fire alarm circuit conductors must be rated to __________.

A) 150V
B) 300V
C) 600V
D) 1000V
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
24
What statement about central station fire alarm systems is true?

A) Are owned and operated by the property owner of the protected premise
B) The central station must be located in the same state as the protected premise
C) The central station must be listed and approved by a recognized testing agency and the AHJ
D) Central stations will only provide service to individual clients
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
25
What type of detector technology is nonrestorable?

A) Thermopiles
B) Temperature sensitive resistors
C) Fusible links
D) Thermistors
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
26
Maximum allowable ceiling temperatures are typically _________ less than the temperature rating of the heat detector.

A) 1 F
B) 5 F
C) 10 F
D) 20 F
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
27
The power source for a power-limited fire alarm system cannot output voltages greater than ________

A) 150V
B) 300V
C) 600V
D) 1000V
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
28
What type of heat detector responds to shifting temperatures that vary excessively beyond a predetermined value?

A) Rate-of-rise
B) Rate compensation
C) Fixed temperature
D) Spot detector
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
29
What statement about line seizure is not true?

A) Achieved through an RJ-31X connector
B) The house phone will continue to operate
C) Cellular phone may be used as a backup
D) Gives the DACT priority access to the phone line
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
30
The Class B system, for initiating devices, connects through a two-wire circuit and _________.

A) Does not use an end of line device
B) Uses an end of line device
C) Is an outdated system no longer used in the United States
D) Uses a series limiting resistor
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 30 flashcards in this deck.