Deck 22: Condensers

Full screen (f)
exit full mode
Question
The following style(s) can be found in air-cooled condensers: ____.

A) vertical airflow pattern, taking air into the bottom and discharging it out the top
B) air blowing horizontally through
C) taking air in at the sides and discharging it out the top
D) All of the above.
Use Space or
up arrow
down arrow
to flip the card.
Question
The desired water flow through a condenser connected to a recirculating water system is approximately 3 gallons per minute per ton of refrigeration .
Question
If an R-12 refrigeration system has its air-cooled condensing unit on a roof with an ambient air temperature of 100°F and the condenser outlet temperature (refrigerant) is 115°F, with how much subcooling is the condenser operating ?

A) 15°F
B) 30°F
C) 100°F
D) 130°F
Question
In a water-cooled condenser with dirty condenser tubes, the temperature difference between the refrigerant and the leaving water will be ____ when the tubes are clean.

A) less than
B) greater than
C) the same as
D) slightly lower than
Question
In a water-cooled condenser, a regulating valve is used to control the ____.

A) refrigerant flow through the pressure reducing device
B) refrigerant head pressure
C) suction pressure
D) water temperature
Question
If the spring pressure of a water regulating valve is increased, the system head pressure will also increase.
Question
The typical design temperature for the water entering a recirculating water system condenser is 85°F, and most systems have a ____ rise across the condenser.

A) 1°F
B) 5°F
C) 10°F
D) 15°F
Question
The water circuit in shell-and-coil and tube-within-a-tube coil condensers must be cleaned ____.

A) by removing the end caps
B) with a brush
C) chemically
D) by air pressure
Question
What can be used to maintain the head pressure of a system with a water-cooled condenser?

A) Fan cycling.
B) Dampers or louvers.
C) Water regulating valve.
D) All of the above.
Question
Mineral deposits on the water side of a water-cooled condenser act as a(n) ____.

A) conductor of heat
B) insulator
C) cleaning solution
D) They have no effect on the operation of the condenser.
Question
The condenser in a refrigeration system ____.

A) desuperheats the vapor from the compressor
B) condenses the vapor from the compressor
C) subcools the liquid refrigerant before it leaves the condenser
D) All of the above.
Question
A water regulating valve helps to maintain a system's head pressure by modulating the flow of refrigerant through the condenser.
Question
A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible ?

A) The outlet water temperature will be lower than expected.
B) The system head pressure will rise.
C) The water regulating valve will close.
D) Both a and b are correct.
Question
High head pressures from low ambients can cause insufficient refrigerant flow rates through metering devices, which in turn can starve evaporators .
Question
One big problem designers face when designing air-cooled refrigeration and air-conditioning equipment is the changing ambient of the changing seasons .
Question
When the evaporative condenser is used in cold climates, freeze protection must be provided in winter .
Question
Which of the following can be used to maintain the head pressure of a system with an air-cooled condenser?

A) Fan cycling.
B) Condenser flooding.
C) Dampers.
D) All of the above.
Question
The shell-and-tube condenser is cleaned ____.

A) with a brush after removing the end caps
B) only with chemicals
C) with compressed air
D) with a vacuum cleaner
Question
The refrigerant in a condenser in a refrigeration system ____.

A) absorbs heat
B) rejects heat
C) changes to a vapor
D) is under lower pressure than the evaporator
Question
An air-cooled condenser that is operating in a climate that has four distinct seasons must ____.

A) have some type of head pressure control
B) use a water regulating valve
C) have a multi-circuit evaporator
D) operate with zero degrees of subcooling
Question
Define "heat reclaim."
Question
An evaporative condenser uses air and ____________________ to desuperheat, condense, and subcool the refrigerant.
Question
What is the condenser saturation temperature if there is 20°F of subcooling and the outlet temperature of the refrigerant is 90°F?
Question
What would the symptom be if an air-cooled condenser had two fans and one stopped running?
Question
In a tube-within-a-tube condenser, the refrigerant flows in the outer tube and the water flows in the inner tube. Why?
Question
Hard starting may also occur in a low ambient condition, causing low head pressures .
Question
What is meant by the term blowdown?
Question
Describe the construction of the tube-within-a-tube condensers .
Question
Define "desuperheat."
Question
Define "subcooling."
Question
In order for a flooded condenser type head pressure control system to operate, a device called a(n) ____________________ holds the extra refrigerant in warmer weather when the condenser doesn't need to be flooded .
Question
Low suction pressures, iced coils, short cycling, and inefficient cooling, can also result from low head pressures .
Question
In a recirculating water system condenser, the leaving water temperature is normally ____________________°F lower than the condensing temperature of the refrigerant .
Question
The heat in the vicinity of the ____________________ gas has a tendency to cause any minerals in the water to deposit onto the tube surface.
Question
If an air-cooled condenser's fan motor stops running, the head pressure will ___________________ .
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/35
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Condensers
1
The following style(s) can be found in air-cooled condensers: ____.

A) vertical airflow pattern, taking air into the bottom and discharging it out the top
B) air blowing horizontally through
C) taking air in at the sides and discharging it out the top
D) All of the above.
D
2
The desired water flow through a condenser connected to a recirculating water system is approximately 3 gallons per minute per ton of refrigeration .
True
3
If an R-12 refrigeration system has its air-cooled condensing unit on a roof with an ambient air temperature of 100°F and the condenser outlet temperature (refrigerant) is 115°F, with how much subcooling is the condenser operating ?

A) 15°F
B) 30°F
C) 100°F
D) 130°F
A
4
In a water-cooled condenser with dirty condenser tubes, the temperature difference between the refrigerant and the leaving water will be ____ when the tubes are clean.

A) less than
B) greater than
C) the same as
D) slightly lower than
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
5
In a water-cooled condenser, a regulating valve is used to control the ____.

A) refrigerant flow through the pressure reducing device
B) refrigerant head pressure
C) suction pressure
D) water temperature
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
6
If the spring pressure of a water regulating valve is increased, the system head pressure will also increase.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
7
The typical design temperature for the water entering a recirculating water system condenser is 85°F, and most systems have a ____ rise across the condenser.

A) 1°F
B) 5°F
C) 10°F
D) 15°F
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
8
The water circuit in shell-and-coil and tube-within-a-tube coil condensers must be cleaned ____.

A) by removing the end caps
B) with a brush
C) chemically
D) by air pressure
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
9
What can be used to maintain the head pressure of a system with a water-cooled condenser?

A) Fan cycling.
B) Dampers or louvers.
C) Water regulating valve.
D) All of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
10
Mineral deposits on the water side of a water-cooled condenser act as a(n) ____.

A) conductor of heat
B) insulator
C) cleaning solution
D) They have no effect on the operation of the condenser.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
11
The condenser in a refrigeration system ____.

A) desuperheats the vapor from the compressor
B) condenses the vapor from the compressor
C) subcools the liquid refrigerant before it leaves the condenser
D) All of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
12
A water regulating valve helps to maintain a system's head pressure by modulating the flow of refrigerant through the condenser.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
13
A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible ?

A) The outlet water temperature will be lower than expected.
B) The system head pressure will rise.
C) The water regulating valve will close.
D) Both a and b are correct.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
14
High head pressures from low ambients can cause insufficient refrigerant flow rates through metering devices, which in turn can starve evaporators .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
15
One big problem designers face when designing air-cooled refrigeration and air-conditioning equipment is the changing ambient of the changing seasons .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
16
When the evaporative condenser is used in cold climates, freeze protection must be provided in winter .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
17
Which of the following can be used to maintain the head pressure of a system with an air-cooled condenser?

A) Fan cycling.
B) Condenser flooding.
C) Dampers.
D) All of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
18
The shell-and-tube condenser is cleaned ____.

A) with a brush after removing the end caps
B) only with chemicals
C) with compressed air
D) with a vacuum cleaner
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
19
The refrigerant in a condenser in a refrigeration system ____.

A) absorbs heat
B) rejects heat
C) changes to a vapor
D) is under lower pressure than the evaporator
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
20
An air-cooled condenser that is operating in a climate that has four distinct seasons must ____.

A) have some type of head pressure control
B) use a water regulating valve
C) have a multi-circuit evaporator
D) operate with zero degrees of subcooling
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
21
Define "heat reclaim."
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
22
An evaporative condenser uses air and ____________________ to desuperheat, condense, and subcool the refrigerant.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
23
What is the condenser saturation temperature if there is 20°F of subcooling and the outlet temperature of the refrigerant is 90°F?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
24
What would the symptom be if an air-cooled condenser had two fans and one stopped running?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
25
In a tube-within-a-tube condenser, the refrigerant flows in the outer tube and the water flows in the inner tube. Why?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
26
Hard starting may also occur in a low ambient condition, causing low head pressures .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
27
What is meant by the term blowdown?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
28
Describe the construction of the tube-within-a-tube condensers .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
29
Define "desuperheat."
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
30
Define "subcooling."
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
31
In order for a flooded condenser type head pressure control system to operate, a device called a(n) ____________________ holds the extra refrigerant in warmer weather when the condenser doesn't need to be flooded .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
32
Low suction pressures, iced coils, short cycling, and inefficient cooling, can also result from low head pressures .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
33
In a recirculating water system condenser, the leaving water temperature is normally ____________________°F lower than the condensing temperature of the refrigerant .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
34
The heat in the vicinity of the ____________________ gas has a tendency to cause any minerals in the water to deposit onto the tube surface.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
35
If an air-cooled condenser's fan motor stops running, the head pressure will ___________________ .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 35 flashcards in this deck.