Deck 18: Viewing the Digital Radiographic Image

Full screen (f)
exit full mode
Question
Flatfielding is accomplished through automatic calibration images called _____ and _____.

A) magnification, edge enhancement
B) offset images, gain images
C) image flip, image lag
D) image inversion, pixel shift
Use Space or
up arrow
down arrow
to flip the card.
Question
PACS stands for _____.

A) Processing, Applications, and Computer Storage
B) Processing, Archiving, and Computer Storage
C) Physician Applications and Communication Systems
D) Picture Archiving and Communication Systems
Question
Almost all medical flat panel digital display devices are _____.

A) color liquid crystal displays
B) monochrome liquid crystal displays
C) color CRTs
D) monochrome CRTs
Question
Post-processing includes all of the following except _____.

A) image inversion
B) signal interpolation
C) annotation
D) pixel shift
Question
Reregistering an image to correct for patient motion is done with _____.

A) edge enhancement
B) offset images
C) pixel shift
D) image inversion
Question
A liquid crystal is a material in a _____ state.

A) solid
B) state between a liquid and a solid
C) liquid
D) state between a liquid and a gaseous
Question
The ambient light at a digital image workstation should be _____.

A) daylight bright
B) slightly dimmed
C) near darkness
D) complete darkness
Question
Medical flat panel display devices are identified by the _____.

A) aperture ratio
B) depth of the monitor
C) size of the pixels
D) number of pixels
Question
_____ is corrected by the application of an offset voltage.

A) Spatial resolution
B) Line noise
C) Image lag
D) Misregistration
Question
The decreasing luminous intensity with increasing distance from the source of light follows _____.

A) the law of gravity
B) Murphy's law
C) cosine law
D) the inverse square law
Question
Preprocessing the digital image is done _____,and post-processing is done _____.

A) automatically, manually
B) manually, manually
C) manually, automatically
D) automatically, automatically
Question
Almost all digital images in medical imaging are viewed and interpreted on a _____.

A) view box
B) CRT device
C) digital display device
D) television monitor
Question
What is the basic photometric unit?

A) lumen
B) candela
C) lux
D) nit
Question
The science of _____ is the study of the response of the human eye to light.

A) physiology
B) optometry
C) photometry
D) ophthalmology
Question
An advantage to viewing the AMLCD screen is that the image quality is equally good viewed from any angle.
Question
A digital display monitor is best viewed _____.

A) straight on
B) from above
C) from below
D) at a 30° angle
Question
Which is not a part of PACS?

A) film storage
B) a display system
C) a network
D) image acquisition
Question
Compared to CRTs,AMLCDs have _____.

A) better contrast
B) better gray scale definition
C) less intrinsic noise
D) all of the above
Question
A computation of the mean pixel value within a region-of-interest is performed for _____.

A) quantitative radiology
B) edge enhancement
C) image inversion
D) window and level adjustment
Question
A digital display device with higher megapixels has better spatial resolution.
Question
The national standard for image transmission in teleradiology is the _____ format.

A) RIS
B) DICOM
C) MB
D) PACS
Question
What is the file size of an image with a 1026 * 1026 matrix and a 2.5 byte gray scale depth?

A) 2,565 bits
B) 1,053 bits
C) 26 MB
D) 2.6 MB
Question
Image file size is determined by _____ size and gray scale.

A) RIS
B) DICOM
C) matrix
D) pixel
Question
Text data and email are generated at a _____ workstation in PACS.

A) Radiology Information System (RIS)
B) DICOM
C) image acquisition
D) archive retrieval
Question
Within a PACS network the secretarial workstation and the viewing workstation would both be called _____.

A) mainframes
B) remote devices
C) clients
D) DICOMs
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 18: Viewing the Digital Radiographic Image
1
Flatfielding is accomplished through automatic calibration images called _____ and _____.

A) magnification, edge enhancement
B) offset images, gain images
C) image flip, image lag
D) image inversion, pixel shift
offset images, gain images
2
PACS stands for _____.

A) Processing, Applications, and Computer Storage
B) Processing, Archiving, and Computer Storage
C) Physician Applications and Communication Systems
D) Picture Archiving and Communication Systems
Picture Archiving and Communication Systems
3
Almost all medical flat panel digital display devices are _____.

A) color liquid crystal displays
B) monochrome liquid crystal displays
C) color CRTs
D) monochrome CRTs
monochrome liquid crystal displays
4
Post-processing includes all of the following except _____.

A) image inversion
B) signal interpolation
C) annotation
D) pixel shift
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
Reregistering an image to correct for patient motion is done with _____.

A) edge enhancement
B) offset images
C) pixel shift
D) image inversion
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
A liquid crystal is a material in a _____ state.

A) solid
B) state between a liquid and a solid
C) liquid
D) state between a liquid and a gaseous
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
The ambient light at a digital image workstation should be _____.

A) daylight bright
B) slightly dimmed
C) near darkness
D) complete darkness
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
Medical flat panel display devices are identified by the _____.

A) aperture ratio
B) depth of the monitor
C) size of the pixels
D) number of pixels
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
_____ is corrected by the application of an offset voltage.

A) Spatial resolution
B) Line noise
C) Image lag
D) Misregistration
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
The decreasing luminous intensity with increasing distance from the source of light follows _____.

A) the law of gravity
B) Murphy's law
C) cosine law
D) the inverse square law
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Preprocessing the digital image is done _____,and post-processing is done _____.

A) automatically, manually
B) manually, manually
C) manually, automatically
D) automatically, automatically
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Almost all digital images in medical imaging are viewed and interpreted on a _____.

A) view box
B) CRT device
C) digital display device
D) television monitor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
What is the basic photometric unit?

A) lumen
B) candela
C) lux
D) nit
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
The science of _____ is the study of the response of the human eye to light.

A) physiology
B) optometry
C) photometry
D) ophthalmology
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
An advantage to viewing the AMLCD screen is that the image quality is equally good viewed from any angle.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
A digital display monitor is best viewed _____.

A) straight on
B) from above
C) from below
D) at a 30° angle
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Which is not a part of PACS?

A) film storage
B) a display system
C) a network
D) image acquisition
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
Compared to CRTs,AMLCDs have _____.

A) better contrast
B) better gray scale definition
C) less intrinsic noise
D) all of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
A computation of the mean pixel value within a region-of-interest is performed for _____.

A) quantitative radiology
B) edge enhancement
C) image inversion
D) window and level adjustment
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
A digital display device with higher megapixels has better spatial resolution.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
The national standard for image transmission in teleradiology is the _____ format.

A) RIS
B) DICOM
C) MB
D) PACS
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
What is the file size of an image with a 1026 * 1026 matrix and a 2.5 byte gray scale depth?

A) 2,565 bits
B) 1,053 bits
C) 26 MB
D) 2.6 MB
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Image file size is determined by _____ size and gray scale.

A) RIS
B) DICOM
C) matrix
D) pixel
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Text data and email are generated at a _____ workstation in PACS.

A) Radiology Information System (RIS)
B) DICOM
C) image acquisition
D) archive retrieval
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Within a PACS network the secretarial workstation and the viewing workstation would both be called _____.

A) mainframes
B) remote devices
C) clients
D) DICOMs
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.