Deck 22: Digital Radiographic Quality Control

Full screen (f)
exit full mode
Question
Specular reflection is reduced with the use of _____.

A) improved anti-reflective coating
B) brighter ambient lighting
C) color monitors
D) larger monitors
Use Space or
up arrow
down arrow
to flip the card.
Question
The quality control standard for flat panel displays was released by _____ in 1998.

A) DIN
B) SMPTE
C) NEMA
D) VESA
Question
A standard pattern made to measure the resolution of digital display systems is called the _____.

A) VESA pattern
B) SMPTE pattern
C) Gray Scale Display Function
D) DICOM standard
Question
Specular reflection can be assessed by only turning off the monitor in ambient light.
Question
When evaluating the test pattern for geometric distortion,all lines should appear _____.

A) blue
B) dashed
C) straight
D) curved
Question
There are _____ types of photometers commonly used.

A) 2
B) 4
C) 6
D) 8
Question
The Task Group Report 18 is a procedure manual for _____.

A) evaluating the Gray Scale Display Function
B) testing digital display devices
C) evaluating the SMPTE pattern
D) testing doing CT exams
Question
Specular reflection can be tested with the _____.
I. TG 18-AD pattern
II. ambient light turned on
III. ambient light turned off

A) I only
B) I & II only
C) I & III only
D) I, II & III
Question
The TG18-LPV/LPH test is used to evaluate _____.

A) display noise
B) luminance response
C) reflection
D) geometric distortion
Question
A telescope photometer is used at _____.

A) close proximity
B) 1 meter
C) a 35° angle
D) a 50° angle
Question
SMPTE stands for the _____.

A) Standards of Medical Practice and Television Electronics
B) Standards of Medical Practice and Technical Electronics
C) Society of Motion Picture and Television Engineers
D) Society of Medical Physicians and Technical Engineers
Question
Digital display reflections and ambient light conditions are assessed with a(n)_____.

A) illuminance meter
B) near-range photometer
C) luminescence meter
D) TG-18 test device
Question
The qualitative evaluation of luminance response is measured with the _____ test tool.

A) TG18-AD
B) TG18-CT
C) TG18-LPV/LPH
D) TG18-LN
Question
Medical images are transferred using the _____ standard.

A) VESA
B) SMPTE
C) DIN
D) DICOM
Question
Luminance response can be tested with a(n)_____.
I. near-range photometer
II. telescope photometer
III. illuminance meter

A) I only
B) II only
C) III only
D) I or II
Question
The consistent appearance of DICOM images on any compatible digital display device is achieved through _____.

A) perceptual linearization
B) SMPTE pattern
C) specular reflection
D) digital driving levels
Question
Spatial resolution of the digital display monitor is done with the _____ test pattern.

A) TG18-CX
B) TG18-AFC
C) TG18-AD
D) TG18-LN
Question
Most of the quality control testing of digital display devices is performed with the use of _____ test patterns.

A) SMPTE
B) AAPM TG18
C) DIN
D) VESA
Question
A photometer is a _____.

A) TG-18 test device
B) dosimeter
C) luminescence meter
D) illuminance meter
Question
The standard for Digital Imaging and Communication was developed by a committee of the _____.

A) ACR and DIN
B) DIN and NEMA
C) ACR and NEMA
D) ACR and VESA
Question
Daily evaluation of the monitors should be done with the _____ test tool.

A) TG18-LPV/LPH
B) TG18-QC
C) TG18-LN
D) TG18-AD
Question
A continuous quality control program for digital display devices should include _____.
I. acceptance testing of any new devices
II. routine quality control
III. periodic review of the program by a medical physicist
IV. annual and post-repair performance evaluations

A) II only
B) I, II & IV
C) II, III & IV
D) I, II, III & IV
Question
Display noise is measured using the _____ test pattern.

A) TG18-QC
B) TG18-AD
C) TG18-AFC
D) TG18-LN
Question
Daily quality control testing is done by the medical physicist.

A) True
B) False
Question
Veiling glare can be evaluated with a VG18 testing pattern.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Digital Radiographic Quality Control
1
Specular reflection is reduced with the use of _____.

A) improved anti-reflective coating
B) brighter ambient lighting
C) color monitors
D) larger monitors
improved anti-reflective coating
2
The quality control standard for flat panel displays was released by _____ in 1998.

A) DIN
B) SMPTE
C) NEMA
D) VESA
NEMA
3
A standard pattern made to measure the resolution of digital display systems is called the _____.

A) VESA pattern
B) SMPTE pattern
C) Gray Scale Display Function
D) DICOM standard
SMPTE pattern
4
Specular reflection can be assessed by only turning off the monitor in ambient light.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
When evaluating the test pattern for geometric distortion,all lines should appear _____.

A) blue
B) dashed
C) straight
D) curved
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
There are _____ types of photometers commonly used.

A) 2
B) 4
C) 6
D) 8
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
The Task Group Report 18 is a procedure manual for _____.

A) evaluating the Gray Scale Display Function
B) testing digital display devices
C) evaluating the SMPTE pattern
D) testing doing CT exams
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
Specular reflection can be tested with the _____.
I. TG 18-AD pattern
II. ambient light turned on
III. ambient light turned off

A) I only
B) I & II only
C) I & III only
D) I, II & III
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
The TG18-LPV/LPH test is used to evaluate _____.

A) display noise
B) luminance response
C) reflection
D) geometric distortion
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
A telescope photometer is used at _____.

A) close proximity
B) 1 meter
C) a 35° angle
D) a 50° angle
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
SMPTE stands for the _____.

A) Standards of Medical Practice and Television Electronics
B) Standards of Medical Practice and Technical Electronics
C) Society of Motion Picture and Television Engineers
D) Society of Medical Physicians and Technical Engineers
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Digital display reflections and ambient light conditions are assessed with a(n)_____.

A) illuminance meter
B) near-range photometer
C) luminescence meter
D) TG-18 test device
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
The qualitative evaluation of luminance response is measured with the _____ test tool.

A) TG18-AD
B) TG18-CT
C) TG18-LPV/LPH
D) TG18-LN
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Medical images are transferred using the _____ standard.

A) VESA
B) SMPTE
C) DIN
D) DICOM
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Luminance response can be tested with a(n)_____.
I. near-range photometer
II. telescope photometer
III. illuminance meter

A) I only
B) II only
C) III only
D) I or II
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
The consistent appearance of DICOM images on any compatible digital display device is achieved through _____.

A) perceptual linearization
B) SMPTE pattern
C) specular reflection
D) digital driving levels
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Spatial resolution of the digital display monitor is done with the _____ test pattern.

A) TG18-CX
B) TG18-AFC
C) TG18-AD
D) TG18-LN
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
Most of the quality control testing of digital display devices is performed with the use of _____ test patterns.

A) SMPTE
B) AAPM TG18
C) DIN
D) VESA
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
A photometer is a _____.

A) TG-18 test device
B) dosimeter
C) luminescence meter
D) illuminance meter
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
The standard for Digital Imaging and Communication was developed by a committee of the _____.

A) ACR and DIN
B) DIN and NEMA
C) ACR and NEMA
D) ACR and VESA
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Daily evaluation of the monitors should be done with the _____ test tool.

A) TG18-LPV/LPH
B) TG18-QC
C) TG18-LN
D) TG18-AD
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
A continuous quality control program for digital display devices should include _____.
I. acceptance testing of any new devices
II. routine quality control
III. periodic review of the program by a medical physicist
IV. annual and post-repair performance evaluations

A) II only
B) I, II & IV
C) II, III & IV
D) I, II, III & IV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Display noise is measured using the _____ test pattern.

A) TG18-QC
B) TG18-AD
C) TG18-AFC
D) TG18-LN
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Daily quality control testing is done by the medical physicist.

A) True
B) False
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Veiling glare can be evaluated with a VG18 testing pattern.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.