Deck 10: Radiographic Image Quality
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
Play
Full screen (f)
Deck 10: Radiographic Image Quality
1
Spatial resolution improves with decreased _________ blur.
A) screen
B) motion
C) geometric
D) All of the above
A) screen
B) motion
C) geometric
D) All of the above
All of the above
2
Focal spot blur can be reduced by using __________.
A) a small focal spot
B) a shorter SID
C) a larger OID
D) All of the above
A) a small focal spot
B) a shorter SID
C) a larger OID
D) All of the above
a small focal spot
3
The base + fog of a film is shown below the __________ of the characteristic curve.
A) straight-line portion
B) average gradient
C) toe portion
D) shoulder portion
A) straight-line portion
B) average gradient
C) toe portion
D) shoulder portion
toe portion
4
What is the formula for optical density?
A) OD = log10(Io/It)
B) OD = log10(It/Io)
C) OD = Io/It
D) OD = It/Io
A) OD = log10(Io/It)
B) OD = log10(It/Io)
C) OD = Io/It
D) OD = It/Io
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
What is the formula for the magnification factor?
A) MF = SID/SOD
B) MF = SOD/SID
C) MF = (SID/SOD)2
D) MF = SID2/SOD
A) MF = SID/SOD
B) MF = SOD/SID
C) MF = (SID/SOD)2
D) MF = SID2/SOD
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
A high quality radiograph should always demonstrate ____________.
A) structures and tissues
B) high contrast
C) minimum magnification
D) All of the above
A) structures and tissues
B) high contrast
C) minimum magnification
D) All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Higher speed image receptors generally produce images with ____________.
A) better resolution
B) increased noise
C) higher contrast
D) improved detail
A) better resolution
B) increased noise
C) higher contrast
D) improved detail
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
The inherent base density plus fog density in film is _______.
A) 0.0-0.1
B) 0.1-0.3
C) 0.5-1.0
D) 1.0-1.3
A) 0.0-0.1
B) 0.1-0.3
C) 0.5-1.0
D) 1.0-1.3
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
If 10% of the viewbox light is transmitted through an area of film, what is the optical density in that area?
A) 0
B) 1
C) 2
D) 3
A) 0
B) 1
C) 2
D) 3
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
In general radiography, the useful optical densities lie between _____ and _____.
A) 0.25, 2.5
B) 0.5, 1.0
C) 1.0, 1.5
D) 2.0, 3.0
A) 0.25, 2.5
B) 0.5, 1.0
C) 1.0, 1.5
D) 2.0, 3.0
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Subject contrast is affected by ___________.
A) mAs
B) focal spot size
C) patient thickness
D) voltage ripple
A) mAs
B) focal spot size
C) patient thickness
D) voltage ripple
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
The slope of the __________ portion of the characteristic curve shows the film contrast.
A) base
B) shoulder
C) toe
D) straight line
A) base
B) shoulder
C) toe
D) straight line
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
_________ is defined as the ability to image two separate objects and visually detect one from the other.
A) Contrast
B) Resolution
C) Detail
D) Noise
A) Contrast
B) Resolution
C) Detail
D) Noise
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
The three primary geometric factors affecting image quality are ________________________.
A) distortion, subject contrast, and mAs
B) patient thickness, distortion, and magnification
C) magnification, distortion, and focal spot blur
D) kVp, focal spot blur, and contrast
A) distortion, subject contrast, and mAs
B) patient thickness, distortion, and magnification
C) magnification, distortion, and focal spot blur
D) kVp, focal spot blur, and contrast
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Distortion can be reduced by ____________________________.
A) placing the object plane perpendicular to the image plane
B) placing the object plane parallel to the image plane
C) directing the central ray 15° from the object plane
D) increasing the SID and the OID
A) placing the object plane perpendicular to the image plane
B) placing the object plane parallel to the image plane
C) directing the central ray 15° from the object plane
D) increasing the SID and the OID
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
An image receptor with ____________ can be used over a greater range of exposures.
A) wide latitude
B) high contrast
C) narrow latitude
D) high average gradient
A) wide latitude
B) high contrast
C) narrow latitude
D) high average gradient
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
The best way to minimize magnification is to use a __________.
A) long SID
B) small OID
C) large OID
D) Both A and B
A) long SID
B) small OID
C) large OID
D) Both A and B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
The densities above 2.5 on a film are represented in the __________ portion of the characteristic curve.
A) base + fog
B) toe
C) straight-line portion
D) shoulder
A) base + fog
B) toe
C) straight-line portion
D) shoulder
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Radiographic __________ is random fluctuation in the optical density of a radiograph.
A) detail
B) contrast
C) noise
D) resolution
A) detail
B) contrast
C) noise
D) resolution
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
A film with a characteristic curve showing a high slope would be useful when ________ is needed.
A) low contrast
B) wide latitude
C) high contrast
D) fine detail
A) low contrast
B) wide latitude
C) high contrast
D) fine detail
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Patient thickness affects image quality by affecting ____________.
A) magnification
B) radiographic contrast
C) focal spot blur
D) All of the above
A) magnification
B) radiographic contrast
C) focal spot blur
D) All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
Optical density is primarily controlled by changing the _____.
A) kVp
B) mAs
C) film
D) SID
A) kVp
B) mAs
C) film
D) SID
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Radiographic image quality is improved when the __________ is increased.
A) source image distance
B) focal spot size
C) film speed
D) screen speed
A) source image distance
B) focal spot size
C) film speed
D) screen speed
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
The technologist primarily controls radiographic contrast by varying the __________.
A) image receptor
B) kilovoltage
C) voltage ripple
D) milliamperage
A) image receptor
B) kilovoltage
C) voltage ripple
D) milliamperage
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Which of these body parts has the highest subject contrast?
A) Abdomen
B) Skull
C) Chest
D) Pelvis
A) Abdomen
B) Skull
C) Chest
D) Pelvis
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck