Deck 19: Oxygen Sensors

Full screen (f)
exit full mode
Question
The sensor that must be warmed and functioning before the engine management computer will go to closed loop is the ________.

A) O2S
B) ECT sensor
C) BARO sensor
D) MAP sensor
Use Space or
up arrow
down arrow
to flip the card.
Question
Where is sensor 1, bank 1 located?

A) On the same bank where number 1 cylinder is located
B) In the exhaust manifold
C) On the bank opposite cylinder number 1
D) Both A and B
Question
A heated Zirconia oxygen sensor will have how many wires?

A) 2
B) 3
C) 4
D) Either B or C
Question
When testing an oxygen sensor using a DSO (digital storage oscilloscope), how quickly should the voltage change when either propane is added to the intake stream or when a vacuum leak is created?

A) Less than 100 ms
B) 100-200 ms
C) 450-550 ms
D) 1-3 seconds
Question
Technician A says that an oxygen sensor produces a voltage output signal based on the oxygen content of the exhaust stream. Technician B says that if the exhaust has little oxygen the voltage of the oxygen sensor will be close to 0 volts. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
Technician A says that oxygen sensors can have one, two, three, four, or more wires, depending on the style and design. Technician B says that if the exhaust has little oxygen, the voltage of the oxygen sensor will be close to 1 volt (1000 mV) and close to zero if there is high oxygen content in the exhaust. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
Technician A says that oxygen sensors can be tested using a test light or dwell meter, or a scan tool. Technician B says that conditions can occur that cause the oxygen sensor to be fooled and give a false lean or false rich signal to the PCM. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
A P0131 DTC is being discussed. Technician A says that an exhaust leak upstream of HO2S (bank 1) oxygen sensor could be the cause. Technician B says that an extremely rich air-fuel mixture could be the cause. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
A P0132 DTC is being discussed. Technician A says that a defective HO2S could be the cause. Technician B says that an HO2S signal wire shorted-to-ground could be the cause. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
When the concentration of oxygen on the exhaust side of the thimble is low (rich exhaust), a voltage of ________ is generated between the electrodes.

A) 0.60-1.0
B) 1.0-2.0
C) 0.25-0.50
D) 10-20
Question
A large amount of oxygen in the exhaust system causes the O2S (Oxygen sensor) to produce which of these?

A) High voltage
B) Abnormal readings
C) Low voltage
D) False readings
Question
What does the post, or downstream, oxygen sensor (HO2S) measure?

A) Amount of H2O in front of the catalytic converter
B) Amount of H2O behind the catalytic converter
C) Amount of oxygen in front of the catalytic converter
D) Amount of oxygen behind the catalytic converter
Question
With the vehicle in closed loop, the following post converter HO2S scope pattern activity is seen. What does this indicate? <strong>With the vehicle in closed loop, the following post converter HO<sub>2</sub>S scope pattern activity is seen. What does this indicate?  </strong> A) A lazy converter B) A good converter C) A missing converter D) A bad converter <div style=padding-top: 35px>

A) A lazy converter
B) A good converter
C) A missing converter
D) A bad converter
Question
With the vehicle in closed loop, the following post converter HO2S scope pattern activity is seen. What does this indicate? <strong>With the vehicle in closed loop, the following post converter HO<sub>2</sub>S scope pattern activity is seen. What does this indicate?  </strong> A) A lazy converter B) A good converter C) A bad converter D) None of these <div style=padding-top: 35px>

A) A lazy converter
B) A good converter
C) A bad converter
D) None of these
Question
The two internal chambers of a dual cell wide band oxygen sensor include ________ and ________.

A) inside; outside
B) single; dual
C) air reference; diffusion
D) Nernst; Pump
Question
When the air/fuel ratio is expressed as lambda, a lambda number of less than 1 indicates a(n) ________ exhaust.

A) rich
B) excessively cold
C) lean
D) excessively hot
Question
Technician A says that a wide-band oxygen sensor, also called a lean air-fuel (LAF) sensor, can detect air-fuel ratios from as rich as 10:1 to as lean as 23:1. Technician B says that the oxygen sensor signal determines fuel trim which is used to tailor the air-fuel mixture for the catalytic converter. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
In some hybrid electric vehicles, the wide band oxygen sensor can cause the PCM to enter closed loop ________.

A) within 10 seconds of engine (ICE) start-up
B) as soon as the engine (ICE) starts
C) by the time the vehicle reaches 60 mph
D) within 2 minutes
Question
Most service information specifies that a(n) ________ be used when testing a wide band oxygen sensor.

A) vacuum hose
B) generic scan tool
C) HO2S disconnect bypass tool
D) factory scan tool
Question
On a poorly running engine, the wide band oxygen sensor can be quickly checked by ________.

A) disconnecting the vehicle battery
B) disconnecting the sensor connector
C) jumping the connector with a jumper wire
D) jumping the connector with a flashlight battery
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 19: Oxygen Sensors
1
The sensor that must be warmed and functioning before the engine management computer will go to closed loop is the ________.

A) O2S
B) ECT sensor
C) BARO sensor
D) MAP sensor
A
2
Where is sensor 1, bank 1 located?

A) On the same bank where number 1 cylinder is located
B) In the exhaust manifold
C) On the bank opposite cylinder number 1
D) Both A and B
D
3
A heated Zirconia oxygen sensor will have how many wires?

A) 2
B) 3
C) 4
D) Either B or C
D
4
When testing an oxygen sensor using a DSO (digital storage oscilloscope), how quickly should the voltage change when either propane is added to the intake stream or when a vacuum leak is created?

A) Less than 100 ms
B) 100-200 ms
C) 450-550 ms
D) 1-3 seconds
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Technician A says that an oxygen sensor produces a voltage output signal based on the oxygen content of the exhaust stream. Technician B says that if the exhaust has little oxygen the voltage of the oxygen sensor will be close to 0 volts. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Technician A says that oxygen sensors can have one, two, three, four, or more wires, depending on the style and design. Technician B says that if the exhaust has little oxygen, the voltage of the oxygen sensor will be close to 1 volt (1000 mV) and close to zero if there is high oxygen content in the exhaust. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Technician A says that oxygen sensors can be tested using a test light or dwell meter, or a scan tool. Technician B says that conditions can occur that cause the oxygen sensor to be fooled and give a false lean or false rich signal to the PCM. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
A P0131 DTC is being discussed. Technician A says that an exhaust leak upstream of HO2S (bank 1) oxygen sensor could be the cause. Technician B says that an extremely rich air-fuel mixture could be the cause. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
A P0132 DTC is being discussed. Technician A says that a defective HO2S could be the cause. Technician B says that an HO2S signal wire shorted-to-ground could be the cause. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
When the concentration of oxygen on the exhaust side of the thimble is low (rich exhaust), a voltage of ________ is generated between the electrodes.

A) 0.60-1.0
B) 1.0-2.0
C) 0.25-0.50
D) 10-20
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
A large amount of oxygen in the exhaust system causes the O2S (Oxygen sensor) to produce which of these?

A) High voltage
B) Abnormal readings
C) Low voltage
D) False readings
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
What does the post, or downstream, oxygen sensor (HO2S) measure?

A) Amount of H2O in front of the catalytic converter
B) Amount of H2O behind the catalytic converter
C) Amount of oxygen in front of the catalytic converter
D) Amount of oxygen behind the catalytic converter
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
With the vehicle in closed loop, the following post converter HO2S scope pattern activity is seen. What does this indicate? <strong>With the vehicle in closed loop, the following post converter HO<sub>2</sub>S scope pattern activity is seen. What does this indicate?  </strong> A) A lazy converter B) A good converter C) A missing converter D) A bad converter

A) A lazy converter
B) A good converter
C) A missing converter
D) A bad converter
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
With the vehicle in closed loop, the following post converter HO2S scope pattern activity is seen. What does this indicate? <strong>With the vehicle in closed loop, the following post converter HO<sub>2</sub>S scope pattern activity is seen. What does this indicate?  </strong> A) A lazy converter B) A good converter C) A bad converter D) None of these

A) A lazy converter
B) A good converter
C) A bad converter
D) None of these
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
The two internal chambers of a dual cell wide band oxygen sensor include ________ and ________.

A) inside; outside
B) single; dual
C) air reference; diffusion
D) Nernst; Pump
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
When the air/fuel ratio is expressed as lambda, a lambda number of less than 1 indicates a(n) ________ exhaust.

A) rich
B) excessively cold
C) lean
D) excessively hot
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Technician A says that a wide-band oxygen sensor, also called a lean air-fuel (LAF) sensor, can detect air-fuel ratios from as rich as 10:1 to as lean as 23:1. Technician B says that the oxygen sensor signal determines fuel trim which is used to tailor the air-fuel mixture for the catalytic converter. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
In some hybrid electric vehicles, the wide band oxygen sensor can cause the PCM to enter closed loop ________.

A) within 10 seconds of engine (ICE) start-up
B) as soon as the engine (ICE) starts
C) by the time the vehicle reaches 60 mph
D) within 2 minutes
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Most service information specifies that a(n) ________ be used when testing a wide band oxygen sensor.

A) vacuum hose
B) generic scan tool
C) HO2S disconnect bypass tool
D) factory scan tool
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
On a poorly running engine, the wide band oxygen sensor can be quickly checked by ________.

A) disconnecting the vehicle battery
B) disconnecting the sensor connector
C) jumping the connector with a jumper wire
D) jumping the connector with a flashlight battery
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.