Deck 8: Electric Arc and Circuit Breaker Protection
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
Play
Full screen (f)
Deck 8: Electric Arc and Circuit Breaker Protection
1
The heat produced at the contact point owing to flow of electric current is least affected by_____________________.
A)Temperature of the surrounding medium.
B)Contact resistance.
C)Magnitude of electric current flowing.
D)Duration of flow of current.
A)Temperature of the surrounding medium.
B)Contact resistance.
C)Magnitude of electric current flowing.
D)Duration of flow of current.
Temperature of the surrounding medium.
2
The resistance of an electric arc can be increased by
A)Increasing the concentration of ionised particles.
B)Reducing the arc length.
C)Splitting the arc
D)Increasing the arc cross section.
A)Increasing the concentration of ionised particles.
B)Reducing the arc length.
C)Splitting the arc
D)Increasing the arc cross section.
Splitting the arc
3
By using low resistance method for arc extension what is the value of arc resistance?
A)Arc resistance is zero.
B)Arc resistance is high
C)Arc resistance is low
D)Arc resistance is very high
A)Arc resistance is zero.
B)Arc resistance is high
C)Arc resistance is low
D)Arc resistance is very high
Arc resistance is low
4
What happens in the arc extinction using high resistance method?
A)Arc resistance is decreased with time.
B)Arc resistance is increased with time.
C)No change it remains same.
D)Arc resistance is kept zero.
A)Arc resistance is decreased with time.
B)Arc resistance is increased with time.
C)No change it remains same.
D)Arc resistance is kept zero.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
What is the arc voltage in a circuit breaker?
A)In phase with the arc current.
B)Lagging the arc current by 90°
C)Leading the arc current by 90°
D)Lagging the arcing current by 180°
A)In phase with the arc current.
B)Lagging the arc current by 90°
C)Leading the arc current by 90°
D)Lagging the arcing current by 180°
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Arcing voltage will be the least in case of
A)Carbon
B)Copper
C)Silver
D)Tungsten
A)Carbon
B)Copper
C)Silver
D)Tungsten
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
How is the initiation of electric arc at the instant of contact separation caused?
A)Thermionic emission of electrons.
B)Field emission of electrons.
C)Both (a) and (b)
D)None of these.
A)Thermionic emission of electrons.
B)Field emission of electrons.
C)Both (a) and (b)
D)None of these.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
The arc resistance depends on which among the following factors?
A)Cross section of the arc
B)Length of the arc
C)Degree of ionization
D)All of the above.
A)Cross section of the arc
B)Length of the arc
C)Degree of ionization
D)All of the above.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
Which type of tripping is generally preferred for the circuit breaker?
A)Manual
B)Automatically
C)Depending on the voltage level
D)None of the above
A)Manual
B)Automatically
C)Depending on the voltage level
D)None of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
Which part of the circuit breaker is helpful in breaking the current?
A)Trip coil.
B)Contacts.
C)Medium
D)Handle.
A)Trip coil.
B)Contacts.
C)Medium
D)Handle.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
When a fault occurs in a high voltage transmission line, what happens first?
A)Circuit breaker operates then the relay.
B)Relay operates and then the circuit breaker.
C)Relay operates, then successively the isolator and the circuit breaker.
D)Isolator operates, then successively the relay and the circuit breaker.
A)Circuit breaker operates then the relay.
B)Relay operates and then the circuit breaker.
C)Relay operates, then successively the isolator and the circuit breaker.
D)Isolator operates, then successively the relay and the circuit breaker.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Upto what voltage can the liquid type HRC fuses be used?
A)33 kV
B)132 kV
C)66 kV
D)220 kV
A)33 kV
B)132 kV
C)66 kV
D)220 kV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
What is the main advantage of using a fuse?
A)Cheapest type of protection.
B)Inverse time current characteristics.
C)Current limiting effect under short circuit conditions.
D)All of above.
A)Cheapest type of protection.
B)Inverse time current characteristics.
C)Current limiting effect under short circuit conditions.
D)All of above.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
On what basis is the selection of fuse done?
A)Steady load
B)Fluctuating load
C)Both (a) and (b)
D)None of these.
A)Steady load
B)Fluctuating load
C)Both (a) and (b)
D)None of these.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Upto what voltage a cartridge type of fuse can be used?
A)400 V
B)11 kV
C)20 kV
D)33 kV
A)400 V
B)11 kV
C)20 kV
D)33 kV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
In a HRC fuse what is the time between the cut off and the final current zero called?
A)Pre - arcing time.
B)Arcing time.
C)Total operating time.
D)None of these.
A)Pre - arcing time.
B)Arcing time.
C)Total operating time.
D)None of these.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Which material is used in the liquid type of fuse?
A)SF6
B)Distilled water
C)Carbon tetra chloride.
D)Mineral oil / transformer oil
A)SF6
B)Distilled water
C)Carbon tetra chloride.
D)Mineral oil / transformer oil
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
What is the advantage of HRC fuses over Rewirable fuses?
A)High speed operation
B)High rupturing capacity
C)No ageing effect.
D)All of the above.
A)High speed operation
B)High rupturing capacity
C)No ageing effect.
D)All of the above.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
If the strands of the fusing wire are twisted, what happens to the fusing current?
A)Increases
B)Reduces.
C)No change/ remains same
D)Depends on the value of current, increases or decreases.
A)Increases
B)Reduces.
C)No change/ remains same
D)Depends on the value of current, increases or decreases.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
What is the typical value of the pre arcing time?
A)0.1
B)0.01
C)0.001
D)0.0001
A)0.1
B)0.01
C)0.001
D)0.0001
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Outdoor switchgear is generally used for voltage beyond
A)11 KV
B)33 KV
C)66 KV
D)132 KV
A)11 KV
B)33 KV
C)66 KV
D)132 KV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
The least expensive protection for over current in low-voltage system is
A)Rewirable fuse
B)Isolator
C)Circuit breaker
D)Air-break switch
A)Rewirable fuse
B)Isolator
C)Circuit breaker
D)Air-break switch
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Purpose of backup protection is
A)To increase the speed
B)To increase a reach
C)To leave no blind spot
D)To guard against failure of primary
A)To increase the speed
B)To increase a reach
C)To leave no blind spot
D)To guard against failure of primary
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
We do not require any protection against prime mover failure in case of
A)Turbo generator sets
B)Hydro generator sets
C)Diesel engine driven alternators
D)Back pressure turbo generators
A)Turbo generator sets
B)Hydro generator sets
C)Diesel engine driven alternators
D)Back pressure turbo generators
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
For the protection of stator winding of an alternate against internal fault involving ground the relay used is a
A)Biased differential relay
B)Directional over-current relay
C)Plain impedance relay
D)Buchholz relay
A)Biased differential relay
B)Directional over-current relay
C)Plain impedance relay
D)Buchholz relay
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck