Deck 6: Transformer and D.C Motor
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
Play
Full screen (f)
Deck 6: Transformer and D.C Motor
1
An open-circuit test on a transformer is conducted primarily to measure
A)insulation resistance
B)copper loss
C)core loss
D)total loss
A)insulation resistance
B)copper loss
C)core loss
D)total loss
core loss
2
A no-load test is performed on a transformer to determine
A)core loss
B)copper loss
C)efficiency
D)magnetising current and loss
A)core loss
B)copper loss
C)efficiency
D)magnetising current and loss
magnetising current and loss
3
The voltage transformation ratio of a transformer is equal to the ratio of
A)primary turns to secondary turns
B)secondary current to primary current
C)secondary induced e.m.f. to primary induced e.m.f.
D)secondary terminal voltage to primary applied voltage
A)primary turns to secondary turns
B)secondary current to primary current
C)secondary induced e.m.f. to primary induced e.m.f.
D)secondary terminal voltage to primary applied voltage
secondary induced e.m.f. to primary induced e.m.f.
4
Part of the transformer which is most subject to damage from overheating is
A)iron core
B)copper winding
C)winding insulation
D)frame or case
A)iron core
B)copper winding
C)winding insulation
D)frame or case
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
If a transformer is switched on to a voltage more than the rated voltage
A)its power factor will deteriorate
B)its power factor will increase
C)its power factor will remain unaffected
D)its power factor will be zero
A)its power factor will deteriorate
B)its power factor will increase
C)its power factor will remain unaffected
D)its power factor will be zero
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Auto-transformer makes effective saving on copper and copper losses, whenits transformation ratio is
A)approximately equal to one
B)less than one
C)great than one
D)none of the above
A)approximately equal to one
B)less than one
C)great than one
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Minimum voltage regulation occurs when the power factor of the load is
A)unity
B)lagging
C)leading
D)zero
A)unity
B)lagging
C)leading
D)zero
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of
A)less than 15 A
B)more than 15 A
C)15 A
D)none of the above
A)less than 15 A
B)more than 15 A
C)15 A
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
No-load speed of which of the following motor will be highest ?
A)Shunt motor
B)Series motor
C)Cumulative compound motor
D)Differentiate compound motor
A)Shunt motor
B)Series motor
C)Cumulative compound motor
D)Differentiate compound motor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
The direction of rotation of a D.C. series motor can be changed by
A)interchanging supply terminals
B)interchanging field terminals
C)either of (a) and (b) above
D)None of the above
A)interchanging supply terminals
B)interchanging field terminals
C)either of (a) and (b) above
D)None of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Which of the following application requires high starting torque ?
A)Lathe machine
B)Centrifugal pump
C)Locomotive
D)Air blower
A)Lathe machine
B)Centrifugal pump
C)Locomotive
D)Air blower
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
If a D.C. motor is to be selected for conveyors, which rriotor would be preferred ?
A)Series motor
B)Shunt motor
C)Differentially compound motor
D)Cumulative compound motor
A)Series motor
B)Shunt motor
C)Differentially compound motor
D)Cumulative compound motor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Which D.C. motor will be preferred for machine tools ?
A)Series motor
B)Shunt motor
C)Cumulative compound motor
D)Differential compound motor
A)Series motor
B)Shunt motor
C)Cumulative compound motor
D)Differential compound motor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Differentially compound D.C. motors can find applicationsrequiring
A)high starting torque
B)low starting torque
C)variable speed
D)frequent on-off cycles
A)high starting torque
B)low starting torque
C)variable speed
D)frequent on-off cycles
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Which D.C. motor is preferred for elevators ?
A)Shunt motor
B)Series motor
C)Differential compound motor
D)Cumulative compound motor
A)Shunt motor
B)Series motor
C)Differential compound motor
D)Cumulative compound motor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
If the field of a D.C. shunt motor gets opened while motor is running
A)the speed of motor will be reduced %
B)the armature current will reduce
C)the motor will attain dangerously high speed 1
D)the motor will continue to nuvat constantspeed
A)the speed of motor will be reduced %
B)the armature current will reduce
C)the motor will attain dangerously high speed 1
D)the motor will continue to nuvat constantspeed
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Starters are used with D.C. motors because
A)these motors have high starting torque
B)these motors are not self-starting
C)back e.m.f. of these motors is zero initially
D)to restrict armature current as there is no back e.m.f. whilestarting
A)these motors have high starting torque
B)these motors are not self-starting
C)back e.m.f. of these motors is zero initially
D)to restrict armature current as there is no back e.m.f. whilestarting
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
In D.C. shunt motors as load is reduced
A)the speed will increase abruptly
B)the speed will increase in proportion to reduction in load
C)the speed will remain almost/constant
D)the speed will reduce
A)the speed will increase abruptly
B)the speed will increase in proportion to reduction in load
C)the speed will remain almost/constant
D)the speed will reduce
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
A D.C. series motor is that which
A)has its field winding consisting of thick wire and lessturns
B)has a poor torque
C)can be started easily without load
D)has almost constant speed
A)has its field winding consisting of thick wire and lessturns
B)has a poor torque
C)can be started easily without load
D)has almost constant speed
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
For starting a D.C. motor a starter is required because
A)it limits the speed of the motor
B)it limits the starting current to a safe value
C)it starts the motor
D)none of the above
A)it limits the speed of the motor
B)it limits the starting current to a safe value
C)it starts the motor
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
The type of D.C. motor used for shears and punches is
A)shunt motor
B)series motor
C)differential compoutid D.C. motor
D)cumulative compound D.C. motor
A)shunt motor
B)series motor
C)differential compoutid D.C. motor
D)cumulative compound D.C. motor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
If a D.C. motor is connected across the A.C. supply it will
A)run at normal speed
B)not run
C)run at lower speed
D)burn due to heat produced in the field winding by .eddy currents
A)run at normal speed
B)not run
C)run at lower speed
D)burn due to heat produced in the field winding by .eddy currents
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
To get the speed of D.C, motor below the normal without wastage of electrical energy is used.
A)Ward Leonard control
B)rheostatic control
C)All of the above method
D)none of the above method
A)Ward Leonard control
B)rheostatic control
C)All of the above method
D)none of the above method
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
When two D.C. series motors are connected in parallel, the resultant speed is
A)more than the normal speed
B)loss than the normal speed
C)normal speed
D)zero
A)more than the normal speed
B)loss than the normal speed
C)normal speed
D)zero
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
The speed of a D.C. shunt motor more than its full-load speed can be obtained by
A)decreasing the field current
B)increasing the field current
C)decreasing the armature current
D)increasing the armature current
A)decreasing the field current
B)increasing the field current
C)decreasing the armature current
D)increasing the armature current
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck