Deck 1: Electrical Power Transmission and Distribution

Full screen (f)
exit full mode
Question
If variable part of annual cost on account of interest and depreciation on the capital outlay is equal to the annual cost of electrical energy wasted in the conductors, the total annual cost will be minimum and the corresponding size of conductor will be most economical. This statement is known as

A)Kelvin's law
B)Ohm's law
C)Kirchhoffs law
D)Faraday's law
Use Space or
up arrow
down arrow
to flip the card.
Question
are the conductors, which connect the consumer's terminals to the distribution

A)Distributors
B)Service mains
C)Feeders
D)None of the above
Question
The underground system cannot be operated above

A)440 V
B)11 kV
C)33 kV
D)66 kV
Question
Overhead system can be designed for operation upto

A)11 kV
B)33 kV
C)66 kV
D)400 kV
Question
The wooden poles well impregnated with creosite oil or any preservative compound have life

A)from 2 to 5 years
B)10 to 15 years
C)25 to 30 years
D)60 to 70 years
Question
Which of the following materials is not used for transmission and distribution of electrical power ?

A)Copper
B)Aluminium
C)Steel
D)Tungsten
Question
Galvanised steel wire is generally used as

A)stay wire
B)earth wire
C)structural components
D)all of the above
Question
The usual spans with R.C.C. poles are

A)40-50 metres
B)60-100 metres
C)80-100 metres
D)300-500 metres
Question
The corona is considerably affected by which of the following ?

A)Size of the conductor
B)Shape of the conductor
C)Surface condition of the conductor
D)All of the above
Question
Which of the following are the constants of the transmission lines ?

A)Resistance
B)Inductance
C)Capacitance
D)All of the above
Question
310 km line is considered as

A)a long line
B)a medium line
C)a short line
D)any of the above
Question
The phenomenon qf rise in voltage at the receiving end of the open-circuited or lightly loaded line is called the

A)Seeback effect
B)Ferranti effect
C)Raman effect
D)none of the above
Question
The square root of the ratio of line impedance and shunt admittance is called the

A)surge impedance of the line
B)conductance of the line
C)regulation of the line
D)none of the above
Question
Which of the following is the demerit of a 'constant voltage transmission system' ?

A)Increase of short-circuit current of the system
B)Availability of steady voltage at all loads at the line terminals
C)Possibility of better protection for the line due to possible use of higher terminal reactances
D)Improvement of power factor at times of moderate and heavy loads
Question
Low voltage cables are meant for use up to

A)l.lkV
B)3.3kV
C)6.6kV
D)llkV
Question
The operating voltage of high voltage cables is upto

A)l.lkV
B)3.3kV
C)6.6kV
D)llkV
Question
The operating voltage of supertension cables is upto

A)3.3 kV
B)6.6 kV
C)11 kV
D)33 kV
Question
The operating voltage of extra high tension cables is upto

A)6.6 kV
B)11 kV
C)33 kV
D)66 kV
Question
Which of the following methods is used for laying of underground cables ?

A)Direct laying
B)Draw-in-system
C)Solid system
D)All of the above
Question
Due to which of the following reasons the cables should not be operated too hot ?

A)The oil may loose its viscosity and it may start drawing off from higher levels
B)Expansion of the oil may cause the sheath to burst
C)Unequal expansion may create voids in the insulation which will lead to ionization
D)All of the above
Question
Which of the following D.C. distribution system is the simplest and lowest in first cost?

A)Radial system
B)Ring system
C)Inter-connected system
D)None of the above
Question
A booster is a

A)series wound generator
B)shunt wound generator
C)synchronous generator
D)none of the above
Question
Besides a method of trial and error, which of the following methods is employed for solution of network problems in interconnected system ?

A)Circulating current method
B)Thevenin's theorem
C)Superposition of currents
D)All of the above
Question
Which of the following faults is most likely to occur in cables ?

A)Cross or short-circuit fault
B)Open circuit fault
C)Breakdown of cable insulation
D)All of the above
Question
The cause of damage to the lead sheath of a cable is

A)crystallisation of the lead through vibration
B)chemical action on the lead when buried in the earth
C)mechanical damage
D)all of the above
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 1: Electrical Power Transmission and Distribution
1
If variable part of annual cost on account of interest and depreciation on the capital outlay is equal to the annual cost of electrical energy wasted in the conductors, the total annual cost will be minimum and the corresponding size of conductor will be most economical. This statement is known as

A)Kelvin's law
B)Ohm's law
C)Kirchhoffs law
D)Faraday's law
Kelvin's law
2
are the conductors, which connect the consumer's terminals to the distribution

A)Distributors
B)Service mains
C)Feeders
D)None of the above
Service mains
3
The underground system cannot be operated above

A)440 V
B)11 kV
C)33 kV
D)66 kV
66 kV
4
Overhead system can be designed for operation upto

A)11 kV
B)33 kV
C)66 kV
D)400 kV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
The wooden poles well impregnated with creosite oil or any preservative compound have life

A)from 2 to 5 years
B)10 to 15 years
C)25 to 30 years
D)60 to 70 years
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following materials is not used for transmission and distribution of electrical power ?

A)Copper
B)Aluminium
C)Steel
D)Tungsten
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Galvanised steel wire is generally used as

A)stay wire
B)earth wire
C)structural components
D)all of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
The usual spans with R.C.C. poles are

A)40-50 metres
B)60-100 metres
C)80-100 metres
D)300-500 metres
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
The corona is considerably affected by which of the following ?

A)Size of the conductor
B)Shape of the conductor
C)Surface condition of the conductor
D)All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
Which of the following are the constants of the transmission lines ?

A)Resistance
B)Inductance
C)Capacitance
D)All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
310 km line is considered as

A)a long line
B)a medium line
C)a short line
D)any of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
The phenomenon qf rise in voltage at the receiving end of the open-circuited or lightly loaded line is called the

A)Seeback effect
B)Ferranti effect
C)Raman effect
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
The square root of the ratio of line impedance and shunt admittance is called the

A)surge impedance of the line
B)conductance of the line
C)regulation of the line
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following is the demerit of a 'constant voltage transmission system' ?

A)Increase of short-circuit current of the system
B)Availability of steady voltage at all loads at the line terminals
C)Possibility of better protection for the line due to possible use of higher terminal reactances
D)Improvement of power factor at times of moderate and heavy loads
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Low voltage cables are meant for use up to

A)l.lkV
B)3.3kV
C)6.6kV
D)llkV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
The operating voltage of high voltage cables is upto

A)l.lkV
B)3.3kV
C)6.6kV
D)llkV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
The operating voltage of supertension cables is upto

A)3.3 kV
B)6.6 kV
C)11 kV
D)33 kV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
The operating voltage of extra high tension cables is upto

A)6.6 kV
B)11 kV
C)33 kV
D)66 kV
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Which of the following methods is used for laying of underground cables ?

A)Direct laying
B)Draw-in-system
C)Solid system
D)All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
Due to which of the following reasons the cables should not be operated too hot ?

A)The oil may loose its viscosity and it may start drawing off from higher levels
B)Expansion of the oil may cause the sheath to burst
C)Unequal expansion may create voids in the insulation which will lead to ionization
D)All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Which of the following D.C. distribution system is the simplest and lowest in first cost?

A)Radial system
B)Ring system
C)Inter-connected system
D)None of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
A booster is a

A)series wound generator
B)shunt wound generator
C)synchronous generator
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Besides a method of trial and error, which of the following methods is employed for solution of network problems in interconnected system ?

A)Circulating current method
B)Thevenin's theorem
C)Superposition of currents
D)All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Which of the following faults is most likely to occur in cables ?

A)Cross or short-circuit fault
B)Open circuit fault
C)Breakdown of cable insulation
D)All of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
The cause of damage to the lead sheath of a cable is

A)crystallisation of the lead through vibration
B)chemical action on the lead when buried in the earth
C)mechanical damage
D)all of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.