Deck 13: Exposure Technique Selection

Full screen (f)
exit full mode
Question
The maximum length of time that an exposure lasts when using AEC is the

A)mAs readout
B)back-up time
C)minimum response time
D)density controls
Use Space or
up arrow
down arrow
to flip the card.
Question
Today's AEC system is most likely use a(n)

A)ionization chamber
B)Geiger counter
C)phototimer
D)none of the above
Question
There is typically a configuration of at least _________ AEC detectors in place

A)2
B)3
C)4
D)5
Question
An ionization chamber is a hollow cell that contains

A)water
B)lead
C)tungsten
D)air
Question
The two types of detectors used in AEC are

A)image intensifiers and phototimers
B)phototimers and ionization chambers
C)ionization chambers and Geiger counters
D)direct and indirect capture
Question
AEC controls the amount of radiation reaching the IR by controlling the

A)time of exposure
B)mA
C)kVp
D)none of the above
Question
Phototimer AEC detectors are usually exit-type devices because

A)the x-rays must exit the patient to get to the detectors
B)the x-rays must exit the grid to get to the detectors
C)the x-rays must exit the image receptor to get to the detectors
Question
When using AEC,the kVp

A)is set higher than usual
B)is set lower than usual
C)is set as appropriate for the study
D)is determined by the AEC system
Question
Ionization chamber AEC detectors are entrance-type devices because the x-rays must

A)enter the detector after passing through the IR
B)enter the detector before entering the patient
C)enter the detector before getting to the IR
Question
These can be adjusted to increase or decrease the amount of radiation needed to terminate the exposure using AEC

A)mAs readout
B)Back-up time
C)Minimum response time
D)Density controls
Question
The actual amount of exposure used for an image when AEC is being used is the

A)mAs readout
B)back-up time
C)minimum response time
D)density controls
Question
The primary purpose of AEC is to

A)reduce patient exposure
B)control the amount of radiation reaching the IR
C)control image contrast
D)eliminate the need for the radiographer to think critically
Question
Using a higher kVp during an AEC examination results in

A)a longer exposure time
B)a shorter exposure time
C)increased patient exposure
D)B and C
Question
The predetermined level of radiation exposure needed to terminate the exposure when using AEC is set by

A)the radiologist
B)the technologist
C)the equipmentservice personnel
D)the manufacturer
Question
The original type of AEC detector was the

A)ionization chamber
B)Geiger counter
C)phototimer
D)none of the above
Question
Once the electric charge from an AEC detector reaches a preset point

A)the patient can leave
B)the kVp will be reduced to 0
C)the exposure will stop
D)All of the above
Question
When the x-rays enter the ionization chamber

A)atoms become ions
B)atoms give up electrons
C)electrons and positive ions become electricity
D)All of the above
Question
The device that converts the light energy to an electrical signal is the

A)photodiode
B)photocathode
C)photomultiplier tube
D)A and C
E)B and C
Question
The shortest exposure time that a radiographic tube with AEC can have is the

A)mAs readout
B)back-up time
C)minimum response time
D)density controls
Question
When using AEC,the radiographer is responsible for determining

A)kVp
B)mAs
C)exposure time
Question
The AEC minimum response time may pose a problem when

A)a long exposure time is needed
B)the patient can easily hold still for the exposure
C)the patient is unable to hold still for the exposure
D)All of the above
Question
If the back-up time is set by the equipment,the exposure time should end when the mAs reaches

A)100
B)400
C)600
D)1000
Question
The detector(s)selected for an image should be

A)the center detector because that is where the central ray is going
B)the two or three detectors that are covered by the part being imaged
C)the ones that are superimposed by the anatomic structure of interest
D)all three so that the system can work properly
Question
If the patient for an AP thoracic spine image is centered so that the spine is not over the top of the detector

A)the film image will be too dark
B)the film image will be too light
C)the IR will be overexposed
D)A and C
Question
The testing to see that the AEC device terminates the exposure at the same level of exposure,regardless of variations in other factors such as kVp or patient thickness is checking for __________________ and optical densities should be within +/- ________

A)reproducibility;0.1
B)calibration;2
C)consistency;0.2
D)none of the above
Question
Anatomically programmed radiography (APR)is a system in which the radiographer selects

A)AEC settings
B)mAs and kVp settings
C)preset settings based on the part being imaged
D)preset settings based on the size of the patient
Question
When there is a significant amount of scatter radiation reaching the detector,the exposure time will

A)be shorter than needed
B)be appropriate
C)be longer than needed
Question
When your patient for an AP abdomen is very heavy,using AEC results in

A)underexposure to the IR
B)overexposure to the IR
C)appropriate exposure to the IR
Question
If the back-up time is shorter than the actual exposure time needed for a properly exposed image

A)the image receptor will be overexposed
B)the image receptor will be underexposed
C)the exposure will be appropriate
Question
The reason to have a back-up time is to

A)protect the patient from excessive exposure
B)make sure the right mAs is used
C)keep the tube from excessive heat-loading
D)A and C
Question
When using AEC,destructive pathologic conditions can cause

A)overexposure
B)underexposure
C)excessive overexposure
Question
Using a lower mA station during an AEC examination results in

A)reduced patient exposure
B)increased exposure time
C)decreased exposure time
D)A and B
Question
When the radiographer has the opportunity to set the back-up time,it should be approximately _____________ of the expected exposure time

A)50%
B)150%
C)250%
D)600%
Question
If the AEC detectors are not completely covered by the part being imaged and are exposed to primary radiation

A)the patient will be overexposed
B)the exposure will terminate very quickly
C)the IR will be exposed to the appropriate amount of radiation
D)none of the above
Question
Which of the following is the most critical aspect of successfully performing an examination using AEC?

A)Centering the anatomy of interest over the detector
B)Using the right mA
C)Using the right kVp
D)Setting the best back-up time
Question
When using AEC with digital imaging,errors resulting in overexposure to the IR result in

A)images that are dark
B)images with appropriate brightness
C)overexposed patients
D)B and C
Question
AEC devices should be calibrated

A)when the unit is first installed
B)at regular intervals
C)when there is a change in the type of IR being used
D)All of the above
Question
Testing to make sure the AEC system produces the same results for multiple identical exposures is checking for ______________ and the optical densities should be within ± ______________

A)reproducibility;0.1
B)calibration;2
C)consistency;0.2
D)none of the above
Question
In imaging a child,a short exposure time is needed for an examination using AEC.The mA setting should

A)be low
B)be mid-range
C)be high
D)It doesn't matter-the AEC device will control the exposure time
Question
If the radiographer is doing an upright chest using AEC but the table bucky is selected

A)the back-up time will be reached
B)the patient will be exposed to excessive radiation
C)the IR will be overexposed
D)All of the above
Question
___________________ identify optimal kVp values and alter the mAs for variations in part thickness

A)Fixed kVp-variable mAs
B)Variable kVp-fixed mAs
C)A and B
Question
With film-screen imaging using AEC,if an AP thoracic spine is imaged using 110 kVp instead of 80 kVp,the density in the area of interest will be __________________ and the image contrast will be ________________________.(Assume all other factors are appropriate. )

A)light;lower
B)dark;higher
C)the same;lower
D)the same;higher
Question
Pre-established guidelines used by the radiographer to select standardized manual or AEC exposure factors for each type of radiographic examination are called

A)anatomical programming
B)exposure technique charts
C)mA reciprocity
D)quantum noise detectors
Question
With digital imaging using AEC,if an AP thoracic spine is imaged using 110 kVp instead of 80 kVp,the brightness in the area of interest is __________________ and the patient exposure is ________________________.(Assume all other factors are appropriate. )

A)darker;higher
B)unchanged;higher
C)lighter;lower
D)unchanged;lower
Question
With digital imaging using AEC,if an AP thoracic spine is imaged using an outside instead of center detector,the brightness in the area of interest will be __________________ and the quantum noise will be ________________________.(Assume all other factors are appropriate. )

A)light;increased
B)appropriate;decreased
C)appropriate;increased
D)dark;decreased
Question
With film-screen imaging using AEC,if an AP thoracic spine is imaged with the central ray passing 3 inches to the right of the spine,the density in the area of interest will be __________________ and the exposure time will be ________________________.(Assume all other factors are appropriate. )

A)light;long
B)light;short
C)appropriate;short
D)dark;long
Question
With film-screen imaging using AEC,if an AP thoracic spine is imaged with the density setting changed from 0 to +2,the density in the area of interest will be __________________ and the exposure time will be ________________________.(Assume all other factors are appropriate. )

A)darker;longer
B)darker;shorter
C)unchanged;unchanged
D)unchanged;shorter
Question
The amount of electric charge produced in an AEC detector depends on the amount of radiation absorbed by the detector.
Question
The AEC system will automatically adjust to changing image receptor types such as switching from a 400-speed film-screen system to a 600-speed film-screen system.
Question
If an AEC has three detectors,only one of the three can be selected for an exposure.
Question
Phototimer AEC devices convert the radiation to light energy.
Question
With digital imaging using AEC,if an AP thoracic spine is imaged with the central ray passing 3 inches to the right of the spine,the brightness in the area of interest is __________________ and the exposure time is ________________________.(Assume all other factors are appropriate. )

A)light;long
B)light;short
C)appropriate;short
D)dark;long
Question
With digital imaging using AEC,if an AP thoracic spine is imaged with the density setting changed from 0 to -2,the brightness in the area of interest is __________________ and the ____________ is increased.(Assume all other factors are appropriate. )

A)decreased;exposure time
B)increased;image contrast
C)appropriate;recorded detail
D)appropriate;quantum noise
Question
Using the plus or minus density controls should be done frequently to produce optimal images with AEC.
Question
With digital imaging using AEC,if an AP thoracic spine is imaged with the density setting changed from 0 to +2,the brightness in the area of interest is __________________ and the exposure time is ________________________.(Assume all other factors are appropriate. )

A)darker;longer
B)darker;shorter
C)unchanged;unchanged
D)unchanged;longer
Question
With film-screen imaging using AEC,if an AP thoracic spine is imaged using an outside instead of center detector,the density in the area of interest will be __________________ and the patient will be ________________________.(Assume all other factors are appropriate. )

A)light;underexposed
B)light;overexposed
C)dark;underexposed
D)appropriate;underexposed
Question
When using AEC,the exit radiation is converted into an electrical signal.
Question
The mAs readout is of little value because there is no need to set manual exposure factors.
Question
AED and phototiming are accurate terms that can be used in place of automatic exposure control.
Question
Which of the following patient conditions require a change in technical factors?

A)Plaster casts.
B)Additive diseases.
C)Destructive diseases.
D)Use of contrast media.
E)All of the above.
Question
Once a part has been selected using APR,the exposure factors cannot be adjusted.
Question
It is safe to assume that APR settings have been developed to produce the best quality images with the least amount of exposure.
Question
Collimation is not required when AEC is used.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/63
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Exposure Technique Selection
1
The maximum length of time that an exposure lasts when using AEC is the

A)mAs readout
B)back-up time
C)minimum response time
D)density controls
back-up time
2
Today's AEC system is most likely use a(n)

A)ionization chamber
B)Geiger counter
C)phototimer
D)none of the above
ionization chamber
3
There is typically a configuration of at least _________ AEC detectors in place

A)2
B)3
C)4
D)5
3
4
An ionization chamber is a hollow cell that contains

A)water
B)lead
C)tungsten
D)air
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
5
The two types of detectors used in AEC are

A)image intensifiers and phototimers
B)phototimers and ionization chambers
C)ionization chambers and Geiger counters
D)direct and indirect capture
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
6
AEC controls the amount of radiation reaching the IR by controlling the

A)time of exposure
B)mA
C)kVp
D)none of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
7
Phototimer AEC detectors are usually exit-type devices because

A)the x-rays must exit the patient to get to the detectors
B)the x-rays must exit the grid to get to the detectors
C)the x-rays must exit the image receptor to get to the detectors
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
8
When using AEC,the kVp

A)is set higher than usual
B)is set lower than usual
C)is set as appropriate for the study
D)is determined by the AEC system
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
9
Ionization chamber AEC detectors are entrance-type devices because the x-rays must

A)enter the detector after passing through the IR
B)enter the detector before entering the patient
C)enter the detector before getting to the IR
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
10
These can be adjusted to increase or decrease the amount of radiation needed to terminate the exposure using AEC

A)mAs readout
B)Back-up time
C)Minimum response time
D)Density controls
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
11
The actual amount of exposure used for an image when AEC is being used is the

A)mAs readout
B)back-up time
C)minimum response time
D)density controls
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
12
The primary purpose of AEC is to

A)reduce patient exposure
B)control the amount of radiation reaching the IR
C)control image contrast
D)eliminate the need for the radiographer to think critically
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
13
Using a higher kVp during an AEC examination results in

A)a longer exposure time
B)a shorter exposure time
C)increased patient exposure
D)B and C
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
14
The predetermined level of radiation exposure needed to terminate the exposure when using AEC is set by

A)the radiologist
B)the technologist
C)the equipmentservice personnel
D)the manufacturer
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
15
The original type of AEC detector was the

A)ionization chamber
B)Geiger counter
C)phototimer
D)none of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
16
Once the electric charge from an AEC detector reaches a preset point

A)the patient can leave
B)the kVp will be reduced to 0
C)the exposure will stop
D)All of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
17
When the x-rays enter the ionization chamber

A)atoms become ions
B)atoms give up electrons
C)electrons and positive ions become electricity
D)All of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
18
The device that converts the light energy to an electrical signal is the

A)photodiode
B)photocathode
C)photomultiplier tube
D)A and C
E)B and C
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
19
The shortest exposure time that a radiographic tube with AEC can have is the

A)mAs readout
B)back-up time
C)minimum response time
D)density controls
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
20
When using AEC,the radiographer is responsible for determining

A)kVp
B)mAs
C)exposure time
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
21
The AEC minimum response time may pose a problem when

A)a long exposure time is needed
B)the patient can easily hold still for the exposure
C)the patient is unable to hold still for the exposure
D)All of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
22
If the back-up time is set by the equipment,the exposure time should end when the mAs reaches

A)100
B)400
C)600
D)1000
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
23
The detector(s)selected for an image should be

A)the center detector because that is where the central ray is going
B)the two or three detectors that are covered by the part being imaged
C)the ones that are superimposed by the anatomic structure of interest
D)all three so that the system can work properly
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
24
If the patient for an AP thoracic spine image is centered so that the spine is not over the top of the detector

A)the film image will be too dark
B)the film image will be too light
C)the IR will be overexposed
D)A and C
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
25
The testing to see that the AEC device terminates the exposure at the same level of exposure,regardless of variations in other factors such as kVp or patient thickness is checking for __________________ and optical densities should be within +/- ________

A)reproducibility;0.1
B)calibration;2
C)consistency;0.2
D)none of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
26
Anatomically programmed radiography (APR)is a system in which the radiographer selects

A)AEC settings
B)mAs and kVp settings
C)preset settings based on the part being imaged
D)preset settings based on the size of the patient
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
27
When there is a significant amount of scatter radiation reaching the detector,the exposure time will

A)be shorter than needed
B)be appropriate
C)be longer than needed
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
28
When your patient for an AP abdomen is very heavy,using AEC results in

A)underexposure to the IR
B)overexposure to the IR
C)appropriate exposure to the IR
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
29
If the back-up time is shorter than the actual exposure time needed for a properly exposed image

A)the image receptor will be overexposed
B)the image receptor will be underexposed
C)the exposure will be appropriate
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
30
The reason to have a back-up time is to

A)protect the patient from excessive exposure
B)make sure the right mAs is used
C)keep the tube from excessive heat-loading
D)A and C
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
31
When using AEC,destructive pathologic conditions can cause

A)overexposure
B)underexposure
C)excessive overexposure
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
32
Using a lower mA station during an AEC examination results in

A)reduced patient exposure
B)increased exposure time
C)decreased exposure time
D)A and B
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
33
When the radiographer has the opportunity to set the back-up time,it should be approximately _____________ of the expected exposure time

A)50%
B)150%
C)250%
D)600%
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
34
If the AEC detectors are not completely covered by the part being imaged and are exposed to primary radiation

A)the patient will be overexposed
B)the exposure will terminate very quickly
C)the IR will be exposed to the appropriate amount of radiation
D)none of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
35
Which of the following is the most critical aspect of successfully performing an examination using AEC?

A)Centering the anatomy of interest over the detector
B)Using the right mA
C)Using the right kVp
D)Setting the best back-up time
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
36
When using AEC with digital imaging,errors resulting in overexposure to the IR result in

A)images that are dark
B)images with appropriate brightness
C)overexposed patients
D)B and C
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
37
AEC devices should be calibrated

A)when the unit is first installed
B)at regular intervals
C)when there is a change in the type of IR being used
D)All of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
38
Testing to make sure the AEC system produces the same results for multiple identical exposures is checking for ______________ and the optical densities should be within ± ______________

A)reproducibility;0.1
B)calibration;2
C)consistency;0.2
D)none of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
39
In imaging a child,a short exposure time is needed for an examination using AEC.The mA setting should

A)be low
B)be mid-range
C)be high
D)It doesn't matter-the AEC device will control the exposure time
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
40
If the radiographer is doing an upright chest using AEC but the table bucky is selected

A)the back-up time will be reached
B)the patient will be exposed to excessive radiation
C)the IR will be overexposed
D)All of the above
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
41
___________________ identify optimal kVp values and alter the mAs for variations in part thickness

A)Fixed kVp-variable mAs
B)Variable kVp-fixed mAs
C)A and B
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
42
With film-screen imaging using AEC,if an AP thoracic spine is imaged using 110 kVp instead of 80 kVp,the density in the area of interest will be __________________ and the image contrast will be ________________________.(Assume all other factors are appropriate. )

A)light;lower
B)dark;higher
C)the same;lower
D)the same;higher
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
43
Pre-established guidelines used by the radiographer to select standardized manual or AEC exposure factors for each type of radiographic examination are called

A)anatomical programming
B)exposure technique charts
C)mA reciprocity
D)quantum noise detectors
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
44
With digital imaging using AEC,if an AP thoracic spine is imaged using 110 kVp instead of 80 kVp,the brightness in the area of interest is __________________ and the patient exposure is ________________________.(Assume all other factors are appropriate. )

A)darker;higher
B)unchanged;higher
C)lighter;lower
D)unchanged;lower
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
45
With digital imaging using AEC,if an AP thoracic spine is imaged using an outside instead of center detector,the brightness in the area of interest will be __________________ and the quantum noise will be ________________________.(Assume all other factors are appropriate. )

A)light;increased
B)appropriate;decreased
C)appropriate;increased
D)dark;decreased
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
46
With film-screen imaging using AEC,if an AP thoracic spine is imaged with the central ray passing 3 inches to the right of the spine,the density in the area of interest will be __________________ and the exposure time will be ________________________.(Assume all other factors are appropriate. )

A)light;long
B)light;short
C)appropriate;short
D)dark;long
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
47
With film-screen imaging using AEC,if an AP thoracic spine is imaged with the density setting changed from 0 to +2,the density in the area of interest will be __________________ and the exposure time will be ________________________.(Assume all other factors are appropriate. )

A)darker;longer
B)darker;shorter
C)unchanged;unchanged
D)unchanged;shorter
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
48
The amount of electric charge produced in an AEC detector depends on the amount of radiation absorbed by the detector.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
49
The AEC system will automatically adjust to changing image receptor types such as switching from a 400-speed film-screen system to a 600-speed film-screen system.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
50
If an AEC has three detectors,only one of the three can be selected for an exposure.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
51
Phototimer AEC devices convert the radiation to light energy.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
52
With digital imaging using AEC,if an AP thoracic spine is imaged with the central ray passing 3 inches to the right of the spine,the brightness in the area of interest is __________________ and the exposure time is ________________________.(Assume all other factors are appropriate. )

A)light;long
B)light;short
C)appropriate;short
D)dark;long
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
53
With digital imaging using AEC,if an AP thoracic spine is imaged with the density setting changed from 0 to -2,the brightness in the area of interest is __________________ and the ____________ is increased.(Assume all other factors are appropriate. )

A)decreased;exposure time
B)increased;image contrast
C)appropriate;recorded detail
D)appropriate;quantum noise
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
54
Using the plus or minus density controls should be done frequently to produce optimal images with AEC.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
55
With digital imaging using AEC,if an AP thoracic spine is imaged with the density setting changed from 0 to +2,the brightness in the area of interest is __________________ and the exposure time is ________________________.(Assume all other factors are appropriate. )

A)darker;longer
B)darker;shorter
C)unchanged;unchanged
D)unchanged;longer
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
56
With film-screen imaging using AEC,if an AP thoracic spine is imaged using an outside instead of center detector,the density in the area of interest will be __________________ and the patient will be ________________________.(Assume all other factors are appropriate. )

A)light;underexposed
B)light;overexposed
C)dark;underexposed
D)appropriate;underexposed
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
57
When using AEC,the exit radiation is converted into an electrical signal.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
58
The mAs readout is of little value because there is no need to set manual exposure factors.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
59
AED and phototiming are accurate terms that can be used in place of automatic exposure control.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
60
Which of the following patient conditions require a change in technical factors?

A)Plaster casts.
B)Additive diseases.
C)Destructive diseases.
D)Use of contrast media.
E)All of the above.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
61
Once a part has been selected using APR,the exposure factors cannot be adjusted.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
62
It is safe to assume that APR settings have been developed to produce the best quality images with the least amount of exposure.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
63
Collimation is not required when AEC is used.
Unlock Deck
Unlock for access to all 63 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 63 flashcards in this deck.