Deck 5: Radiographic Image Quality: Geometric Properties

Full screen (f)
exit full mode
Question
When the SID is divided by the SOD, what is the result called?

A) Magnification factor
B) Degree of unsharpness
C) OID
D) Image width
Use Space or
up arrow
down arrow
to flip the card.
Question
The unit of line pairs per millimeter is a measure of:

A) distortion.
B) resolution.
C) magnification.
D) quantum mottle.
Question
What effect will using a slower speed imaging system have on recorded detail?

A) Increased recorded detail
B) Decreased recorded detail
C) No effect on recorded detail
Question
Using a small focal spot size may be prohibited due to the:

A) amount of heat produced by x-ray exposure.
B) amount of exposure time used.
C) SID used.
D) speed of the film-screen system.
Question
The misrepresentation of the size of an object is:

A) shape distortion.
B) magnification.
C) foreshortening.
D) elongation.
Question
Providing clear instructions to the patient is a primary method for reducing unsharpness due to:

A) shape distortion.
B) motion.
C) geometric properties.
D) size distortion.
Question
Poor film-screen contact will result in:

A) increased patient exposure.
B) decreased patient exposure.
C) increased recorded detail.
D) decreased recorded detail.
Question
During the selection of the focal spot size, the radiographer is really determining the:

A) angle of the anode used.
B) actual size of the filament used.
C) number of electrons available for tube current.
D) distance the electrons travel from cathode to anode.
Question
Shape distortion can be created by:

A) off-centering the central ray.
B) angling the central ray.
C) increasing the SID.
D) a and b only
Question
Magnification is affected by:

A) AEC.
B) OID.
C) SID.
D) b and c
Question
If the image size measures 4.6 inches and the magnification factor is 1.42, what is the size of the object?

A) 2.43 inches
B) 3.24 inches
C) 5.63 inches
D) 6.53 inches
Question
The most detrimental factor to maximum recorded detail is:

A) increased OID.
B) decreased SID.
C) large focal spot size.
D) motion.
Question
The relationship of the focal spot size, SID, and OID specifically impacts the _____ of the image.

A) visibility of recorded detail
B) image receptor unsharpness
C) geometric unsharpness
D) distortion
Question
If the object size measures 6.2 inches and the image size measures 7.5 inches, what is the magnification factor?

A) 0.83
B) 1.21
C) 1.30
D) 13.7
Question
The SOD can be found by:

A) adding SID and OID.
B) adding the MF to the OID.
C) subtracting the OID from SID.
D) subtracting the SID from the MF.
Question
What effect will using a higher grid ratio have on recorded detail?

A) Increased recorded detail
B) Decreased recorded detail
C) No effect on recorded detail
Question
In order to image a structure that is located anteriorly in the body, it is best radiographed to minimize magnification by doing a _____ projection.

A) posterior-anterior
B) anterior-posterior
C) lateral
D) oblique
Question
What effect will increasing SID have on recorded detail?

A) Increased recorded detail
B) Decreased recorded detail
C) No effect on recorded detail
Question
The property of the x-ray beam that impacts the unsharpness on the radiograph is beam:

A) quality.
B) quantity.
C) divergence.
D) restriction.
Question
What is the geometric unsharpness when the focal spot measures 0.8 mm, the SID is 40 inches (100 cm), and the OID is 2 inches (5 cm)?

A) 0.042 mm
B) 0.42 mm
C) 4.2 inches
D) 4.2 cm
Question
The pinhole camera is a device that is used to measure:

A) SID.
B) OID.
C) focal spot size.
D) resolution.
Question
The smallest detail that can be detected in an image refers to:

A) contrast resolution.
B) spatial resolution.
C) geometric unsharpness.
D) distortion.
Question
All of the geometric factors and those that determine the amount of image distortion are equally important for digital and film-screen imaging.
Question
SID indicators should be accurate within ______ of the SID.

A) 1%
B) 2%
C) 5%
D) 10%
Question
The ability of the system to differentiate between two small objects that have similar subject contrast refers to:

A) contrast resolution.
B) spatial resolution.
C) geometric unsharpness.
D) distortion.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 5: Radiographic Image Quality: Geometric Properties
1
When the SID is divided by the SOD, what is the result called?

A) Magnification factor
B) Degree of unsharpness
C) OID
D) Image width
Magnification factor
2
The unit of line pairs per millimeter is a measure of:

A) distortion.
B) resolution.
C) magnification.
D) quantum mottle.
resolution.
3
What effect will using a slower speed imaging system have on recorded detail?

A) Increased recorded detail
B) Decreased recorded detail
C) No effect on recorded detail
Increased recorded detail
4
Using a small focal spot size may be prohibited due to the:

A) amount of heat produced by x-ray exposure.
B) amount of exposure time used.
C) SID used.
D) speed of the film-screen system.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
The misrepresentation of the size of an object is:

A) shape distortion.
B) magnification.
C) foreshortening.
D) elongation.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Providing clear instructions to the patient is a primary method for reducing unsharpness due to:

A) shape distortion.
B) motion.
C) geometric properties.
D) size distortion.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Poor film-screen contact will result in:

A) increased patient exposure.
B) decreased patient exposure.
C) increased recorded detail.
D) decreased recorded detail.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
During the selection of the focal spot size, the radiographer is really determining the:

A) angle of the anode used.
B) actual size of the filament used.
C) number of electrons available for tube current.
D) distance the electrons travel from cathode to anode.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
Shape distortion can be created by:

A) off-centering the central ray.
B) angling the central ray.
C) increasing the SID.
D) a and b only
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
Magnification is affected by:

A) AEC.
B) OID.
C) SID.
D) b and c
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
If the image size measures 4.6 inches and the magnification factor is 1.42, what is the size of the object?

A) 2.43 inches
B) 3.24 inches
C) 5.63 inches
D) 6.53 inches
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
The most detrimental factor to maximum recorded detail is:

A) increased OID.
B) decreased SID.
C) large focal spot size.
D) motion.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
The relationship of the focal spot size, SID, and OID specifically impacts the _____ of the image.

A) visibility of recorded detail
B) image receptor unsharpness
C) geometric unsharpness
D) distortion
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
If the object size measures 6.2 inches and the image size measures 7.5 inches, what is the magnification factor?

A) 0.83
B) 1.21
C) 1.30
D) 13.7
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
The SOD can be found by:

A) adding SID and OID.
B) adding the MF to the OID.
C) subtracting the OID from SID.
D) subtracting the SID from the MF.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
What effect will using a higher grid ratio have on recorded detail?

A) Increased recorded detail
B) Decreased recorded detail
C) No effect on recorded detail
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
In order to image a structure that is located anteriorly in the body, it is best radiographed to minimize magnification by doing a _____ projection.

A) posterior-anterior
B) anterior-posterior
C) lateral
D) oblique
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
What effect will increasing SID have on recorded detail?

A) Increased recorded detail
B) Decreased recorded detail
C) No effect on recorded detail
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
The property of the x-ray beam that impacts the unsharpness on the radiograph is beam:

A) quality.
B) quantity.
C) divergence.
D) restriction.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
What is the geometric unsharpness when the focal spot measures 0.8 mm, the SID is 40 inches (100 cm), and the OID is 2 inches (5 cm)?

A) 0.042 mm
B) 0.42 mm
C) 4.2 inches
D) 4.2 cm
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
The pinhole camera is a device that is used to measure:

A) SID.
B) OID.
C) focal spot size.
D) resolution.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
The smallest detail that can be detected in an image refers to:

A) contrast resolution.
B) spatial resolution.
C) geometric unsharpness.
D) distortion.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
All of the geometric factors and those that determine the amount of image distortion are equally important for digital and film-screen imaging.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
SID indicators should be accurate within ______ of the SID.

A) 1%
B) 2%
C) 5%
D) 10%
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
The ability of the system to differentiate between two small objects that have similar subject contrast refers to:

A) contrast resolution.
B) spatial resolution.
C) geometric unsharpness.
D) distortion.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.