Deck 5: Processor Quality Control

Full screen (f)
exit full mode
Question
Which type of graph is used to document the results from the sensitometric testing of film processors?

A)Control chart
B)Histogram
C)Pareto chart
D)Fishbone chart
Use Space or
up arrow
down arrow
to flip the card.
Question
B + F is measured in the

A)clear area of the film.
B)lightest step in the pattern.
C)medium step in the pattern.
D)darkest step in the pattern.
Question
Processing time should not vary by more than ____ of the manufacturer's recommendation.

A)±1% to 2%
B)±2% to 3%
C)±5% to 7%
D)±10% to 15%
Question
Which of the following devices is used to create a 21-step wedge pattern on a film during sensitometric testing?

A)Densitometer
B)Sensitometer
C)Film duplicator
D)Ultraviolet light
Question
Which of the following is acceptable for a variation in the B + F (base + fog) value during sensitometric testing in radiography?

A)±0.01
B)±0.03
C)±0.05
D)±0.10
Question
Which of the following is acceptable for variation in the mid-density indicator during sensitometric testing in radiography?

A)±0.05
B)±0.10
C)±0.15
D)±0.20
Question
Replenishment rates should not vary by more than ____ of the manufacturer's recommendation.

A)±1%
B)±2%
C)±5%
D)±10%
Question
Variation during sensitometric testing that occurs because of the test film being run in different parts of the feed tray is called

A)bromide drag.
B)locational effect.
C)time of day variability.
D)bias.
Question
Which of the following is obtained by subtracting the Dmᵢn from the Dmₐₓ?

A)Speed indicator
B)Mid-density indicator
C)High-density indicator
D)Contrast indicator
Question
Which of the following would be the acceptable temperature variation allowable in automatic film processor quality control?

A)±0.5° F
B)±1° F
C)±1.5° F
D)±2° F
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 5: Processor Quality Control
1
Which type of graph is used to document the results from the sensitometric testing of film processors?

A)Control chart
B)Histogram
C)Pareto chart
D)Fishbone chart
A
2
B + F is measured in the

A)clear area of the film.
B)lightest step in the pattern.
C)medium step in the pattern.
D)darkest step in the pattern.
A
3
Processing time should not vary by more than ____ of the manufacturer's recommendation.

A)±1% to 2%
B)±2% to 3%
C)±5% to 7%
D)±10% to 15%
B
4
Which of the following devices is used to create a 21-step wedge pattern on a film during sensitometric testing?

A)Densitometer
B)Sensitometer
C)Film duplicator
D)Ultraviolet light
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Which of the following is acceptable for a variation in the B + F (base + fog) value during sensitometric testing in radiography?

A)±0.01
B)±0.03
C)±0.05
D)±0.10
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following is acceptable for variation in the mid-density indicator during sensitometric testing in radiography?

A)±0.05
B)±0.10
C)±0.15
D)±0.20
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
Replenishment rates should not vary by more than ____ of the manufacturer's recommendation.

A)±1%
B)±2%
C)±5%
D)±10%
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Variation during sensitometric testing that occurs because of the test film being run in different parts of the feed tray is called

A)bromide drag.
B)locational effect.
C)time of day variability.
D)bias.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Which of the following is obtained by subtracting the Dmᵢn from the Dmₐₓ?

A)Speed indicator
B)Mid-density indicator
C)High-density indicator
D)Contrast indicator
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Which of the following would be the acceptable temperature variation allowable in automatic film processor quality control?

A)±0.5° F
B)±1° F
C)±1.5° F
D)±2° F
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.