Deck 13: Special Considerations on Safety in Computed Tomography and Mammography

Full screen (f)
exit full mode
Question
Which of the following are relevant dose parameters in CT?
1)CT dose index (CTDI)
2)CTDIw
3)CTDIVOL
4)Dose length product (DLP)

A)1,2,and 3 only
B)2,3,and 4 only
C)1,3,and 4 only
D)1,2,3,and 4
Use Space or
up arrow
down arrow
to flip the card.
Question
DLP represents the product of the CTDIVOL and the irradiated scan length.In what unit of measure is it usually expressed?

A)mGy-cm
B)mSv-cm
C)mGy-mSv
D)mSv-mRa
Question
For routine head and body computed tomography examinations,effective doses fall into which of the following effective dose ranges?

A)1 to 10 mSv
B)20 to 30 mSv
C)40 to 50 mSv
D)60 to 70 mSv
Question
Which of the following terms are synonymous?
1)Automatic exposure control
2)Iterative reconstruction
3)Tube current modulation

A)1 and 2 only
B)1 and 3 only
C)2 and 3 only
D)1,2,and 3
Question
Filtering refers to changing the projection data before doing the back projections to remove the

A)blurriness.
B)contrast.
C)grayness.
D)scattered radiation.
Question
Which of the following is not typically used during a CT scan?
1)A tightly collimated x-ray beam
2)Direct patient shielding
3)Filtered back projection

A)1 only
B)2 only
C)3 only
D)1,2,and 3
Question
Digital mammography units with the ability to enhance contrast with image gray-level manipulation offer

A)substantial improvement for patients with small breasts.
B)substantial improvement for patients with microcalcifications in small breasts.
C)substantial improvement for patients with dense breasts.
D)poor quality images for patients with dense breasts and microcalcifications.
Question
Which of the following terms are synonymous in relation to computed tomography?
1)Diagonal
2)Helical
3)Spiral

A)1 and 2 only
B)1 and 3 only
C)2 and 3 only
D)1,2,and 3
Question
In CT when a series of adjacent slices is obtained,some radiation will also scatter from the slice being made into the adjacent slices.What is this radiation called?

A)Forward scatter
B)Backscatter
C)Interslice scatter
D)Side scatter
Question
In spiral image acquisition,the patient table moves during the acquisition so that a

A)single-dimension image is obtained.
B)three-dimensional data set is obtained.
C)four-dimensional data set is obtained.
D)six-dimensional data set is obtained.
Question
In mammography maintaining and enhancing subject contrast is

A)not important.
B)minimally important.
C)of paramount importance for all patients.
D)only important for patients with dense breasts.
Question
The entrance exposure from a CT examination may be compared with the entrance exposure received during which of the following procedures?

A)Screening mammography
B)A routine radiographic series of the lumbar spine with five projections
C)A routine radiographic series of the paranasal sinuses with four projections
D)A routine fluoroscopic examination
Question
A miscentering of ________ can produce as much as __________% increase in patient dose.

A)2 cm;50
B)2 cm;25
C)1 cm;75
D)1 cm;60
Question
For mammography molybdenum filters allow a (an)_________________ than rhodium filters.

A)higher energy window
B)lower energy window
C)equal energy window
D)comparable energy window
Question
During mammography,axillary projections should be done only on request of the

A)ordering physician.
B)patient.
C)radiologist.
D)technologist performing the examination.
Question
With higher radiation exposure to the patient during a computed tomography examination,there is

A)a decreased associated cancer risk because the radiation is more penetrating.
B)an increased associated cancer risk.
C)a negligible associated cancer risk because the radiation is less penetrating.
D)an extremely large cancer risk.
Question
In CT because of higher effective energy of the x-ray beam,both ____________ and _______________ interactions contribute substantially to the image.

A)coherent;photodisintegration
B)classical;pair production
C)photoelectric;Compton
D)Compton;photodisintegration
Question
Verifying that the center of the patient coincides with the center of the CT gantry is a significant part of dose reduction strategies that is under the control of the

A)CT technologist.
B)hospital or imaging facility administrator.
C)ordering physician.
D)patient.
Question
Lower tube current is used in anatomic regions where there is ____________ attenuation because the anatomy is ____________ or _________ dense.

A)increased;thicker;more
B)decreased;thicker;more
C)increased;thinner;less
D)decreased;thinner;less
Question
Tube current modulation in CT scanning can

A)increase patient dose significantly.
B)increase patient dose only slightly.
C)help to reduce patient dose.
D)not affect patient dose.
Question
In the early 2000s various publications calculated individual and population risks of cancer from CT based upon risk estimates from studies of which of the following groups of people?

A)Atomic bomb survivors
B)Early radiologists and radiographers
C)Patients undergoing treatment for thyroid cancer
D)The general public who were exposed to natural background radiation
Question
The movement or advancement of the patient couch is known as

A)optimization.
B)iterative reconstruction.
C)tube current modulation.
D)table increment.
Question
In computed tomography the dose at the edge of a beam does not decrease to _________ immediately.

A)15 cGy
B)10 cGy
C)5 cGy
D)0 (zero)
Question
Which of the following groups advocate annual mammography screening or mammography screening at least every other year?
1)American College of Radiology
2)American Cancer Society
3)American Medical Association

A)1 and 2 only
B)1 and 3 only
C)2 and 3 only
D)1,2,and 3
Question
______________ is the relationship between the movement or advancement of the patient couch and the x-ray beam collimator dimension.

A)Dose distribution
B)Iterative reconstruction
C)Pitch
D)Tube current modulation
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Special Considerations on Safety in Computed Tomography and Mammography
1
Which of the following are relevant dose parameters in CT?
1)CT dose index (CTDI)
2)CTDIw
3)CTDIVOL
4)Dose length product (DLP)

A)1,2,and 3 only
B)2,3,and 4 only
C)1,3,and 4 only
D)1,2,3,and 4
1,2,3,and 4
2
DLP represents the product of the CTDIVOL and the irradiated scan length.In what unit of measure is it usually expressed?

A)mGy-cm
B)mSv-cm
C)mGy-mSv
D)mSv-mRa
mGy-cm
3
For routine head and body computed tomography examinations,effective doses fall into which of the following effective dose ranges?

A)1 to 10 mSv
B)20 to 30 mSv
C)40 to 50 mSv
D)60 to 70 mSv
1 to 10 mSv
4
Which of the following terms are synonymous?
1)Automatic exposure control
2)Iterative reconstruction
3)Tube current modulation

A)1 and 2 only
B)1 and 3 only
C)2 and 3 only
D)1,2,and 3
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
Filtering refers to changing the projection data before doing the back projections to remove the

A)blurriness.
B)contrast.
C)grayness.
D)scattered radiation.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following is not typically used during a CT scan?
1)A tightly collimated x-ray beam
2)Direct patient shielding
3)Filtered back projection

A)1 only
B)2 only
C)3 only
D)1,2,and 3
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Digital mammography units with the ability to enhance contrast with image gray-level manipulation offer

A)substantial improvement for patients with small breasts.
B)substantial improvement for patients with microcalcifications in small breasts.
C)substantial improvement for patients with dense breasts.
D)poor quality images for patients with dense breasts and microcalcifications.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
Which of the following terms are synonymous in relation to computed tomography?
1)Diagonal
2)Helical
3)Spiral

A)1 and 2 only
B)1 and 3 only
C)2 and 3 only
D)1,2,and 3
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
In CT when a series of adjacent slices is obtained,some radiation will also scatter from the slice being made into the adjacent slices.What is this radiation called?

A)Forward scatter
B)Backscatter
C)Interslice scatter
D)Side scatter
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
In spiral image acquisition,the patient table moves during the acquisition so that a

A)single-dimension image is obtained.
B)three-dimensional data set is obtained.
C)four-dimensional data set is obtained.
D)six-dimensional data set is obtained.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
In mammography maintaining and enhancing subject contrast is

A)not important.
B)minimally important.
C)of paramount importance for all patients.
D)only important for patients with dense breasts.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
The entrance exposure from a CT examination may be compared with the entrance exposure received during which of the following procedures?

A)Screening mammography
B)A routine radiographic series of the lumbar spine with five projections
C)A routine radiographic series of the paranasal sinuses with four projections
D)A routine fluoroscopic examination
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
A miscentering of ________ can produce as much as __________% increase in patient dose.

A)2 cm;50
B)2 cm;25
C)1 cm;75
D)1 cm;60
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
For mammography molybdenum filters allow a (an)_________________ than rhodium filters.

A)higher energy window
B)lower energy window
C)equal energy window
D)comparable energy window
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
During mammography,axillary projections should be done only on request of the

A)ordering physician.
B)patient.
C)radiologist.
D)technologist performing the examination.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
With higher radiation exposure to the patient during a computed tomography examination,there is

A)a decreased associated cancer risk because the radiation is more penetrating.
B)an increased associated cancer risk.
C)a negligible associated cancer risk because the radiation is less penetrating.
D)an extremely large cancer risk.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
In CT because of higher effective energy of the x-ray beam,both ____________ and _______________ interactions contribute substantially to the image.

A)coherent;photodisintegration
B)classical;pair production
C)photoelectric;Compton
D)Compton;photodisintegration
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
Verifying that the center of the patient coincides with the center of the CT gantry is a significant part of dose reduction strategies that is under the control of the

A)CT technologist.
B)hospital or imaging facility administrator.
C)ordering physician.
D)patient.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Lower tube current is used in anatomic regions where there is ____________ attenuation because the anatomy is ____________ or _________ dense.

A)increased;thicker;more
B)decreased;thicker;more
C)increased;thinner;less
D)decreased;thinner;less
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
Tube current modulation in CT scanning can

A)increase patient dose significantly.
B)increase patient dose only slightly.
C)help to reduce patient dose.
D)not affect patient dose.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
In the early 2000s various publications calculated individual and population risks of cancer from CT based upon risk estimates from studies of which of the following groups of people?

A)Atomic bomb survivors
B)Early radiologists and radiographers
C)Patients undergoing treatment for thyroid cancer
D)The general public who were exposed to natural background radiation
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
The movement or advancement of the patient couch is known as

A)optimization.
B)iterative reconstruction.
C)tube current modulation.
D)table increment.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
In computed tomography the dose at the edge of a beam does not decrease to _________ immediately.

A)15 cGy
B)10 cGy
C)5 cGy
D)0 (zero)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Which of the following groups advocate annual mammography screening or mammography screening at least every other year?
1)American College of Radiology
2)American Cancer Society
3)American Medical Association

A)1 and 2 only
B)1 and 3 only
C)2 and 3 only
D)1,2,and 3
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
______________ is the relationship between the movement or advancement of the patient couch and the x-ray beam collimator dimension.

A)Dose distribution
B)Iterative reconstruction
C)Pitch
D)Tube current modulation
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.