Deck 3: Radiation Characteristics

Full screen (f)
exit full mode
Question
When contrasted with the use of 70 kV for dental x-rays,the use of 60 kV produces

A)more penetrating dental x-rays with longer wavelength.
B)less penetrating dental x-rays with longer wavelength.
C)more penetrating dental x-rays with shorter wavelength.
D)less penetrating dental x-rays with shorter wavelength.
Use Space or
up arrow
down arrow
to flip the card.
Question
Aluminum filters are used to remove _______-energy,________ wavelength x-rays.

A)low;longer
B)high;longer
C)low;shorter
D)high;shorter
Question
When the kilovoltage is increased

A)electrons move from the anode to the cathode with more speed.
B)photons move from the anode to the cathode with more speed.
C)electrons move from the cathode to the anode with more speed.
D)photons move from the cathode to the anode with more speed.
Question
Which of the following statements is true of the use of voltage in dental x-ray equipment?

A)Dental x-ray equipment requires the use of 3 to 5 volts.
B)Dental x-ray equipment requires the use of less than 60 kilovolts.
C)Dental x-ray equipment uses more than 70 kilovolts.
D)Dental x-ray equipment requires the use of 60 to 70 kilovolts.
Question
When lower kilovoltage settings are used,an image with ____ will result.

A)high contrast
B)low contrast
C)many shades of gray
D)there is no change in contrast
Question
(1)Density is the overall darkness or blackness of a dental image.(2)When the kilovoltage is increased while other exposure factors remain constant,the resultant image exhibits a decreased density and appears lighter.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
Question
Which of the following statements is true of wavelength in reference to radiation?

A)X-rays with shorter wavelength have less penetrating power.
B)X-rays with longer wavelength have less penetrating power.
C)X-rays with longer wavelength are less likely to be absorbed by matter.
D)Milliamperage controls the wavelength and energy of the x-ray beam.
Question
According to the inverse square law,the intensity of radiation is __________ proportional to the ______________ from the source of radiation.

A)directly;distance
B)directly;square of the distance
C)inversely;distance
D)inversely;square of the distance
Question
Aluminum filters

A)remove more penetrating x-rays from the beam.
B)decrease the mean penetrating ability of the x-ray beam.
C)remove high-energy x-rays from the beam.
D)reduce the intensity of the x-ray beam.
Question
Which of the following changes will increase x-ray beam intensity?

A)Decreasing the kilovoltage
B)Decreasing the milliamperage
C)Decreasing the exposure time
D)Decreasing the source-to-film distance
Question
When kilovolt is increased,a

A)lower energy x-ray beam with increased penetrating ability results.
B)lower energy x-ray beam with decreased penetrating ability results.
C)higher energy x-ray beam with increased penetrating ability results.
D)higher energy x-ray beam with decreased penetrating ability results.
Question
In dental radiography,the term ________ is used to describe the mean energy or penetrating ability of the x-ray beam.

A)quality
B)quantity
C)intensity
D)wavelength
Question
According to the inverse square law,if the length of the PID is halved,the resultant beam is ___________ as intense.

A)four times
B)twice
C)half
D)one quarter
Question
Milliamperage regulates the _________ of electrons produced at the cathode filament.

A)quality
B)quantity
C)speed
D)power
Question
Exposure time is measured in

A)kV.
B)milliamperage.
C)density.
D)impulses.
Question
______________ is a measurement of force that refers to the potential difference between two electrical charges.

A)Exposure time
B)Wavelength
C)Voltage
D)Ampere
Question
The kVp represents

A)the mean x-ray tube voltage.
B)the mean filament voltage.
C)the maximum or peak voltage of an alternating current.
D)the maximum or peak voltage of a direct current.
Question
An image with "low" contrast

A)is useful for the detection of periodontal or periapical disease and has many shades of gray.
B)is useful for the detection and progression of dental caries and has many shades of gray.
C)is useful for the detection of periodontal or periapical disease and has many black and white areas.
D)is useful for the detection and progression of dental caries and has many black and white areas.
Question
In regard to increasing density

A)an increase in either kV or mA will increase density.
B)an increase in kV will increase density,but an increase in mA will not increase density.
C)an increase in mA will increase density,but an increase in kV will not increase density.
D)neither an increase in kV nor an increase in mA will increase density.
Question
The quantity of the x-rays produced is controlled by

A)voltage.
B)kilovoltage.
C)kilovoltage peak.
D)milliamperage.
Question
You have been using a dental x-ray machine that has a 4-inch PID.Your new machine has an 8-inch PID.Given that all exposure factors remain the same,according to the inverse square law,the resultant beam would be ___________ as intense.

A)four times
B)twice
C)half
D)one quarter
Question
(1)As kilovoltage,milliamperage,and time increase,x-ray beam intensity decreases.(2)As distance and filtration increase,the intensity of the x-ray beam increases.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
Question
You are going to take dental images on your patient.He is larger than average.What machine setting adjustment should you make prior to taking dental images?

A)Increase kV.
B)Increase mA.
C)Increase impulses.
D)You don't need to make any adjustments.
Question
You have taken your first dental image on your patient.The contrast is high and you are looking for periodontal disease.You are using a DC machine and you have control of your settings.You have a 60- to 70-kV range and a 6- to 8-mA range.You had the kV set at 60,the mA set at 7,and the impulses set at 6/100.While leaving all other settings the same,which setting would you adjust to create better contrast for detecting periodontal disease?

A)Increase kV to 70.
B)Increase mA to 8.
C)Decrease mA to 6.
D)Increase time to 7/100.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/24
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 3: Radiation Characteristics
1
When contrasted with the use of 70 kV for dental x-rays,the use of 60 kV produces

A)more penetrating dental x-rays with longer wavelength.
B)less penetrating dental x-rays with longer wavelength.
C)more penetrating dental x-rays with shorter wavelength.
D)less penetrating dental x-rays with shorter wavelength.
less penetrating dental x-rays with longer wavelength.
2
Aluminum filters are used to remove _______-energy,________ wavelength x-rays.

A)low;longer
B)high;longer
C)low;shorter
D)high;shorter
low;longer
3
When the kilovoltage is increased

A)electrons move from the anode to the cathode with more speed.
B)photons move from the anode to the cathode with more speed.
C)electrons move from the cathode to the anode with more speed.
D)photons move from the cathode to the anode with more speed.
electrons move from the cathode to the anode with more speed.
4
Which of the following statements is true of the use of voltage in dental x-ray equipment?

A)Dental x-ray equipment requires the use of 3 to 5 volts.
B)Dental x-ray equipment requires the use of less than 60 kilovolts.
C)Dental x-ray equipment uses more than 70 kilovolts.
D)Dental x-ray equipment requires the use of 60 to 70 kilovolts.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
5
When lower kilovoltage settings are used,an image with ____ will result.

A)high contrast
B)low contrast
C)many shades of gray
D)there is no change in contrast
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
6
(1)Density is the overall darkness or blackness of a dental image.(2)When the kilovoltage is increased while other exposure factors remain constant,the resultant image exhibits a decreased density and appears lighter.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following statements is true of wavelength in reference to radiation?

A)X-rays with shorter wavelength have less penetrating power.
B)X-rays with longer wavelength have less penetrating power.
C)X-rays with longer wavelength are less likely to be absorbed by matter.
D)Milliamperage controls the wavelength and energy of the x-ray beam.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
8
According to the inverse square law,the intensity of radiation is __________ proportional to the ______________ from the source of radiation.

A)directly;distance
B)directly;square of the distance
C)inversely;distance
D)inversely;square of the distance
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
9
Aluminum filters

A)remove more penetrating x-rays from the beam.
B)decrease the mean penetrating ability of the x-ray beam.
C)remove high-energy x-rays from the beam.
D)reduce the intensity of the x-ray beam.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
10
Which of the following changes will increase x-ray beam intensity?

A)Decreasing the kilovoltage
B)Decreasing the milliamperage
C)Decreasing the exposure time
D)Decreasing the source-to-film distance
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
11
When kilovolt is increased,a

A)lower energy x-ray beam with increased penetrating ability results.
B)lower energy x-ray beam with decreased penetrating ability results.
C)higher energy x-ray beam with increased penetrating ability results.
D)higher energy x-ray beam with decreased penetrating ability results.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
12
In dental radiography,the term ________ is used to describe the mean energy or penetrating ability of the x-ray beam.

A)quality
B)quantity
C)intensity
D)wavelength
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
13
According to the inverse square law,if the length of the PID is halved,the resultant beam is ___________ as intense.

A)four times
B)twice
C)half
D)one quarter
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
14
Milliamperage regulates the _________ of electrons produced at the cathode filament.

A)quality
B)quantity
C)speed
D)power
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
15
Exposure time is measured in

A)kV.
B)milliamperage.
C)density.
D)impulses.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
16
______________ is a measurement of force that refers to the potential difference between two electrical charges.

A)Exposure time
B)Wavelength
C)Voltage
D)Ampere
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
17
The kVp represents

A)the mean x-ray tube voltage.
B)the mean filament voltage.
C)the maximum or peak voltage of an alternating current.
D)the maximum or peak voltage of a direct current.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
18
An image with "low" contrast

A)is useful for the detection of periodontal or periapical disease and has many shades of gray.
B)is useful for the detection and progression of dental caries and has many shades of gray.
C)is useful for the detection of periodontal or periapical disease and has many black and white areas.
D)is useful for the detection and progression of dental caries and has many black and white areas.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
19
In regard to increasing density

A)an increase in either kV or mA will increase density.
B)an increase in kV will increase density,but an increase in mA will not increase density.
C)an increase in mA will increase density,but an increase in kV will not increase density.
D)neither an increase in kV nor an increase in mA will increase density.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
20
The quantity of the x-rays produced is controlled by

A)voltage.
B)kilovoltage.
C)kilovoltage peak.
D)milliamperage.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
21
You have been using a dental x-ray machine that has a 4-inch PID.Your new machine has an 8-inch PID.Given that all exposure factors remain the same,according to the inverse square law,the resultant beam would be ___________ as intense.

A)four times
B)twice
C)half
D)one quarter
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
22
(1)As kilovoltage,milliamperage,and time increase,x-ray beam intensity decreases.(2)As distance and filtration increase,the intensity of the x-ray beam increases.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
23
You are going to take dental images on your patient.He is larger than average.What machine setting adjustment should you make prior to taking dental images?

A)Increase kV.
B)Increase mA.
C)Increase impulses.
D)You don't need to make any adjustments.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
24
You have taken your first dental image on your patient.The contrast is high and you are looking for periodontal disease.You are using a DC machine and you have control of your settings.You have a 60- to 70-kV range and a 6- to 8-mA range.You had the kV set at 60,the mA set at 7,and the impulses set at 6/100.While leaving all other settings the same,which setting would you adjust to create better contrast for detecting periodontal disease?

A)Increase kV to 70.
B)Increase mA to 8.
C)Decrease mA to 6.
D)Increase time to 7/100.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 24 flashcards in this deck.