Deck 9: Blood Bank Automation for Transfusion Services

Full screen (f)
exit full mode
Question
A negative reaction in the MTS Gel test would appear as a:

A)pellet of cells at the bottom of the column.
B)layer of cells at the top of the column.
C)cells evenly distributed throughout the column.
D)cells distributed only in the bottom half of the column.
Use Space or
up arrow
down arrow
to flip the card.
Question
The PROVUE,TANGO,and NEO have the ability to perform all of the following tests except:

A)ABO/D typing.
B)antibody ID panels.
C)direct antiglobulin test.
D)None of the above are correct.
Question
LIS interfaces is an important component in automation because of its potential in:

A)recognizing errors in sample ID.
B)flagging discrepancies with previous test results.
C)providing a mechanism for the electronic crossmatch.
D)all of the above.
Question
An advantage of the MTS Gel technology over test tubes when performing panels is:

A)shorter centrifugation time.
B)decreased reagent cost.
C)reduced patient sample requirements.
D)the incubation step is optional.
Question
True or False: The determination of the ABO and D type by the NEO and TANGO uses the same solid phase red cell adherence technique that is used for the antibody screen.

A)True
B)False
Question
The TANGO,PROVUE,and NEO all use which of the following reagents or components used in the indirect antiglobulin test?

A)Washing mechanism
B)Centrifuge
C)Indicator cells
D)Antihuman globulin
Question
Assays using Gel technology are performed with which of the following instruments:

A)ECHO
B)PROVUE
C)NEO
D)TANGO
Question
Before implementing new automation technology into the transfusion service setting,which of the following is required?

A)Validation
B)Training
C)Written procedures
D)All of the above
Question
A smooth layer of cells in the bottom of the well is interpreted as a/an _____ reaction when the solid phase testing is completed for the antiglobulin test:

A)positive
B)negative
C)indeterminate
D)mixed field
Question
Random access is an important feature in selecting an automated instrument for testing in the transfusion service.Random access refers to:

A)ability of multiple users to sign into the system.
B)the recognition of various types of barcodes.
C)the need for minimal maintenance procedures.
D)the ability to accommodate STAT testing.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 9: Blood Bank Automation for Transfusion Services
1
A negative reaction in the MTS Gel test would appear as a:

A)pellet of cells at the bottom of the column.
B)layer of cells at the top of the column.
C)cells evenly distributed throughout the column.
D)cells distributed only in the bottom half of the column.
A
The cells at the bottom of the column indicate a negative reaction because no agglutination took place with the antibody suspended in the gel.
2
The PROVUE,TANGO,and NEO have the ability to perform all of the following tests except:

A)ABO/D typing.
B)antibody ID panels.
C)direct antiglobulin test.
D)None of the above are correct.
D
All instruments have the ability to perform ABO/D typing,antibody panels,and the DAT.
3
LIS interfaces is an important component in automation because of its potential in:

A)recognizing errors in sample ID.
B)flagging discrepancies with previous test results.
C)providing a mechanism for the electronic crossmatch.
D)all of the above.
D
The laboratory information system interface (LIS)is an essential component that provides for correct sample recognition and comparison with prior records;in doing this,LIS meets some of the criteria for the electronic crossmatch.
4
An advantage of the MTS Gel technology over test tubes when performing panels is:

A)shorter centrifugation time.
B)decreased reagent cost.
C)reduced patient sample requirements.
D)the incubation step is optional.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
True or False: The determination of the ABO and D type by the NEO and TANGO uses the same solid phase red cell adherence technique that is used for the antibody screen.

A)True
B)False
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
The TANGO,PROVUE,and NEO all use which of the following reagents or components used in the indirect antiglobulin test?

A)Washing mechanism
B)Centrifuge
C)Indicator cells
D)Antihuman globulin
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
Assays using Gel technology are performed with which of the following instruments:

A)ECHO
B)PROVUE
C)NEO
D)TANGO
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Before implementing new automation technology into the transfusion service setting,which of the following is required?

A)Validation
B)Training
C)Written procedures
D)All of the above
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
A smooth layer of cells in the bottom of the well is interpreted as a/an _____ reaction when the solid phase testing is completed for the antiglobulin test:

A)positive
B)negative
C)indeterminate
D)mixed field
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Random access is an important feature in selecting an automated instrument for testing in the transfusion service.Random access refers to:

A)ability of multiple users to sign into the system.
B)the recognition of various types of barcodes.
C)the need for minimal maintenance procedures.
D)the ability to accommodate STAT testing.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.