Deck 31: Quality Management

Full screen (f)
exit full mode
Question
Which monitoring tests should be done on a daily basis?

A)collimator accuracy
B)focal spot size estimation
C)processor sensitometry
D)all of the above
Use Space or
up arrow
down arrow
to flip the card.
Question
Input for the purchase of new radiographic equipment should include the

A)radiologists.
B)radiographers.
C)administrators.
D)all of the above
Question
The accuracy of single-phase generator time settings can be measured with a

A)sensitometer.
B)densitometer.
C)spinning top test.
D)penetrometer.
Question
Focal spots measuring 0.3 mm or less should be measured with a

A)star test pattern.
B)pinhole camera.
C)spinning top.
D)all of the above
Question
Each of the following monitoring tests should be done on a semiannual basis EXCEPT

A)processor sensitometry.
B)focal spot size estimation.
C)collimator accuracy.
D)kilovoltage accuracy.
Question
Routine quality management procedures should be performed by the

A)radiation physicist.
B)qualified radiographer.
C)chief radiologist.
D)maintenance personnel.
Question
When testing collimator accuracy, an SID error of ____ is allowed.

A)20%
B)10%
C)2%
D)0%
Question
Quality assurance includes each of the following EXCEPT

A)equipment maintenance.
B)filing systems.
C)diagnosis.
D)scheduling.
Question
The largest hospital accreditation agency is the

A)MSQA.
B)The Joint Commission.
C)SMDA.
D)FDA.
Question
The centering mark should be within ____ of the light field central ray.

A)0%
B)1%
C)11%
D)100%
Question
A generator must be recalibrated when the kVp drifts beyond ____ kVp of the labeled setting.

A)2
B)5
C)10
D)12
Question
The accuracy of three-phase generator time settings can be measured with a

A)motorized synchronous spinning top test.
B)densitometer.
C)spinning top test.
D)penetrometer.
Question
Distance indicators are checked with a

A)yardstick.
B)densitometer.
C)laser.
D)tape measure.
Question
Test tools for focal spot size estimation include each of the following EXCEPT a

A)pinhole camera.
B)star test pattern.
C)line pair resolution tool.
D)motorized synchronous top.
Question
The Joint Commission approval is linked to ____ reimbursement.

A)federal
B)state
C)insurance company
D)all of the above
Question
Exposure time settings should be maintained within ____ of the labeled setting.

A)+ 5%
B)+ 10%
C)+ 15%
D)0%
Question
Which type of equipment is used to measure half-value layers?

A)sensitometer
B)aluminum filters
C)dosimetry equipment
D)more than one of the above
Question
The source-to-skin distance limit for a stationary fluoroscopic unit is ____ inches.

A)5
B)12
C)15
D)25
Question
Installation and acceptance testing of equipment is the responsibility of the

A)radiation physicist.
B)radiology supervisor.
C)radiology equipment vendor.
D)staff radiographer.
Question
Focal spots measuring 0.3 mm or more should be measured with a

A)star test pattern.
B)pinhole camera.
C)spinning top.
D)all of the above
Question
Match the following choices with the correct statement as each relates to quality management.
minimum SSD for portable fluoroscopic units

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Question
Tomographic systems should be tested for each of the following EXCEPT

A)automatic brightness control.
B)completeness of motion.
C)section depth indicator accuracy.
D)section thickness accuracy.
Question
A qualified x-ray service engineer should be used to evaluate and correct the following radiographic/fluoroscopic imaging features:
1) film processor sensitometry
2) automatic brightness control
3) source-to-skin distance limits
4) fluoroscopic contrast
5)image display monitor brightness/contrast
6)AEC reproducibility

A)1, 2, 4, and 5 only
B)2, 3, 5, and 6 only
C)2, 4, 5, and 6 only
D)1, 3, 4, and 6 only
Question
An effective method to assess department image quality is to perform a repeat image analysis.This procedure will demonstrate which of the following department traits?
1) percent of repeat images per room
2) percent of repeat images per radiographer
3) automatic brightness control instability
4) radiologist interpretation accuracy
5) radiographer positioning accuracy
6) patient exam waiting times
7) equipment malfunctions
8) radiographer exposure technique accuracy
9) transmission times to PACS

A)1, 2, 3, 7, and 9 only
B)1, 2, 5, 7, and 8 only
C)3, 4, 6, 7, and 9 only
D)2, 5, and 8 only
Question
Computerized storage and transmission systems for digitized images of all types are called

A)DSR.
B)MRI.
C)CT.
D)PACS.
Question
A common device to measure display monitor quality and characteristics is a/an

A)screen contact test tool.
B)kVp test tool.
C)ABC resolution phantom.
D)SMPTE pattern.
Question
The accuracy of mA stations on a radiographic generator

A)should be measured after the timer and kVp accuracy have been confirmed.
B)tend to drift as the tube ages.
C)are measured using mR/mAs calculations across all mA stations.
D)all of the above
Question
You have just taken a CR radiograph of a patient's knee and the S# is 225.Unfortunately, the image has some degree of motion distortion and needs to be repeated using the same exposure settings.In repeating the image, the new image shows no motion but the S# is now 400.No changes were made to collimation, patient position, exposure techniques, etc.Based upon this new S# value,

A)exposure reproducibility is suspect.
B)the mR/mAs is equal.
C)the exposure reproducibility is within tolerable limits.
D)all of the above
Question
Match the following choices with the correct statement as each relates to quality management.
20 mAs is 20 mAs, repeatedly.

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Question
Match the following choices with the correct statement as each relates to quality management.
used to check high frequency generator timer

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Question
Most AECs utilize ____ ion chambers in various combinations.

A)one
B)two
C)three
D)four
Question
Match the following choices with the correct statement as each relates to quality management.
A value of 1 is ideal.

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Question
Tomographic system uniformity and completeness of motion are tested with a

A)pinhole camera.
B)wire mesh.
C)lead mask with a pinhole.
D)all of the above
Question
Match the following choices with the correct statement as each relates to quality management.
collimator-to-receptor accuracy

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Question
Match the following choices with the correct statement as each relates to quality management.
enacted in 1992 to improve image quality and diagnostic accuracy

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Question
Digital detectors with a higher DQE will

A)require more dose to image adequately.
B)produce better images of small objects with low subject contrast.
C)produce a higher S:N ratio.
D)are not preferred for mammography due to dose.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/36
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 31: Quality Management
1
Which monitoring tests should be done on a daily basis?

A)collimator accuracy
B)focal spot size estimation
C)processor sensitometry
D)all of the above
processor sensitometry
2
Input for the purchase of new radiographic equipment should include the

A)radiologists.
B)radiographers.
C)administrators.
D)all of the above
all of the above
3
The accuracy of single-phase generator time settings can be measured with a

A)sensitometer.
B)densitometer.
C)spinning top test.
D)penetrometer.
spinning top test.
4
Focal spots measuring 0.3 mm or less should be measured with a

A)star test pattern.
B)pinhole camera.
C)spinning top.
D)all of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
5
Each of the following monitoring tests should be done on a semiannual basis EXCEPT

A)processor sensitometry.
B)focal spot size estimation.
C)collimator accuracy.
D)kilovoltage accuracy.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
6
Routine quality management procedures should be performed by the

A)radiation physicist.
B)qualified radiographer.
C)chief radiologist.
D)maintenance personnel.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
7
When testing collimator accuracy, an SID error of ____ is allowed.

A)20%
B)10%
C)2%
D)0%
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
8
Quality assurance includes each of the following EXCEPT

A)equipment maintenance.
B)filing systems.
C)diagnosis.
D)scheduling.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
9
The largest hospital accreditation agency is the

A)MSQA.
B)The Joint Commission.
C)SMDA.
D)FDA.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
10
The centering mark should be within ____ of the light field central ray.

A)0%
B)1%
C)11%
D)100%
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
11
A generator must be recalibrated when the kVp drifts beyond ____ kVp of the labeled setting.

A)2
B)5
C)10
D)12
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
12
The accuracy of three-phase generator time settings can be measured with a

A)motorized synchronous spinning top test.
B)densitometer.
C)spinning top test.
D)penetrometer.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
13
Distance indicators are checked with a

A)yardstick.
B)densitometer.
C)laser.
D)tape measure.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
14
Test tools for focal spot size estimation include each of the following EXCEPT a

A)pinhole camera.
B)star test pattern.
C)line pair resolution tool.
D)motorized synchronous top.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
15
The Joint Commission approval is linked to ____ reimbursement.

A)federal
B)state
C)insurance company
D)all of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
16
Exposure time settings should be maintained within ____ of the labeled setting.

A)+ 5%
B)+ 10%
C)+ 15%
D)0%
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
17
Which type of equipment is used to measure half-value layers?

A)sensitometer
B)aluminum filters
C)dosimetry equipment
D)more than one of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
18
The source-to-skin distance limit for a stationary fluoroscopic unit is ____ inches.

A)5
B)12
C)15
D)25
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
19
Installation and acceptance testing of equipment is the responsibility of the

A)radiation physicist.
B)radiology supervisor.
C)radiology equipment vendor.
D)staff radiographer.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
20
Focal spots measuring 0.3 mm or more should be measured with a

A)star test pattern.
B)pinhole camera.
C)spinning top.
D)all of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
21
Match the following choices with the correct statement as each relates to quality management.
minimum SSD for portable fluoroscopic units

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
22
Tomographic systems should be tested for each of the following EXCEPT

A)automatic brightness control.
B)completeness of motion.
C)section depth indicator accuracy.
D)section thickness accuracy.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
23
A qualified x-ray service engineer should be used to evaluate and correct the following radiographic/fluoroscopic imaging features:
1) film processor sensitometry
2) automatic brightness control
3) source-to-skin distance limits
4) fluoroscopic contrast
5)image display monitor brightness/contrast
6)AEC reproducibility

A)1, 2, 4, and 5 only
B)2, 3, 5, and 6 only
C)2, 4, 5, and 6 only
D)1, 3, 4, and 6 only
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
24
An effective method to assess department image quality is to perform a repeat image analysis.This procedure will demonstrate which of the following department traits?
1) percent of repeat images per room
2) percent of repeat images per radiographer
3) automatic brightness control instability
4) radiologist interpretation accuracy
5) radiographer positioning accuracy
6) patient exam waiting times
7) equipment malfunctions
8) radiographer exposure technique accuracy
9) transmission times to PACS

A)1, 2, 3, 7, and 9 only
B)1, 2, 5, 7, and 8 only
C)3, 4, 6, 7, and 9 only
D)2, 5, and 8 only
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
25
Computerized storage and transmission systems for digitized images of all types are called

A)DSR.
B)MRI.
C)CT.
D)PACS.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
26
A common device to measure display monitor quality and characteristics is a/an

A)screen contact test tool.
B)kVp test tool.
C)ABC resolution phantom.
D)SMPTE pattern.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
27
The accuracy of mA stations on a radiographic generator

A)should be measured after the timer and kVp accuracy have been confirmed.
B)tend to drift as the tube ages.
C)are measured using mR/mAs calculations across all mA stations.
D)all of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
28
You have just taken a CR radiograph of a patient's knee and the S# is 225.Unfortunately, the image has some degree of motion distortion and needs to be repeated using the same exposure settings.In repeating the image, the new image shows no motion but the S# is now 400.No changes were made to collimation, patient position, exposure techniques, etc.Based upon this new S# value,

A)exposure reproducibility is suspect.
B)the mR/mAs is equal.
C)the exposure reproducibility is within tolerable limits.
D)all of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
29
Match the following choices with the correct statement as each relates to quality management.
20 mAs is 20 mAs, repeatedly.

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
30
Match the following choices with the correct statement as each relates to quality management.
used to check high frequency generator timer

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
31
Most AECs utilize ____ ion chambers in various combinations.

A)one
B)two
C)three
D)four
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
32
Match the following choices with the correct statement as each relates to quality management.
A value of 1 is ideal.

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
33
Tomographic system uniformity and completeness of motion are tested with a

A)pinhole camera.
B)wire mesh.
C)lead mask with a pinhole.
D)all of the above
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
34
Match the following choices with the correct statement as each relates to quality management.
collimator-to-receptor accuracy

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
35
Match the following choices with the correct statement as each relates to quality management.
enacted in 1992 to improve image quality and diagnostic accuracy

A)synchronous motor spinning top
B)2% of SID
C)DQE
D)MQSA
E)12 inches
F)S:N ratio
G)exposure reproducibility
H)15 inches
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
36
Digital detectors with a higher DQE will

A)require more dose to image adequately.
B)produce better images of small objects with low subject contrast.
C)produce a higher S:N ratio.
D)are not preferred for mammography due to dose.
Unlock Deck
Unlock for access to all 36 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 36 flashcards in this deck.