Deck 35: Mobile Radiography

Full screen (f)
exit full mode
Question
During optimal mobile radiography of the chest, the recommended SID is ____ inches.

A)72
B)56
C)40
D)36
Use Space or
up arrow
down arrow
to flip the card.
Question
How many lead aprons should be carried to a mobile radiographic examination?

A)none; lead aprons are not necessary
B)one for the radiographer
C)one for the patient
D)two: one for the patient and one for the radiographer
Question
The more advanced, full-power mobile units use ____ energy for a power supply.

A)solar
B)battery
C)thermal
D)alternating current
Question
Modern mobile radiographic units possess

A)a flat panel detector for image review.
B)disposable, single-use batteries.
C)a cabinet for film cassette storage.
D)remote exposure controls.
Question
Proper tube-grid alignment is important during ____ radiography.

A)mobile
B)stationary
C)portable
D)all of the above
Question
For mobile radiography, radiographic grids should have a

A)high ratio and low frequency.
B)low ratio and low frequency.
C)cross-hatch design.
D)low ratio and high frequency.
Question
During mobile radiography, it is the radiographer's responsibility to protect

A)the patient.
B)other health professionals.
C)the public.
D)all of the above
Question
During mobile radiography, the radiographer must achieve maximum distance primarily from the

A)patient.
B)mobile unit.
C)image receptor.
D)x-ray tube.
Question
In surgery or in the emergency unit, which situation should be considered?

A)the stress of performing in a high-tension environment
B)limitations due to aseptic conditions
C)the presence of additional critical equipment
D)all of the above
Question
During mobile radiography, it is the radiographer's responsibility to request that ____ leave the immediate area prior to exposure.

A)physicians
B)family members
C)health professionals
D)all of the above
Question
Which grid type would permit wide exposure and centering latitude and would therefore be preferred for mobile radiography?

A)6:1
B)8:1
C)10:1
D)12:1
Question
When it is determined that air-fluid level demonstration is a priority, ____ projection(s) may be required for ____.

A)one; air-fluid levels
B)one; a normal projection of the chest
C)two; one AP and one lateral projection
D)two; air-fluid levels and a normal projection of the chest
Question
A common cause for repeat examinations in mobile radiography is due to

A)equipment reliability.
B)angulation of grids and grid-off.
C)inaccurate SID measurements.
D)low image contrast.
Question
All of the following are true of capacitor-discharge units EXCEPT:

A)Their output is a function of large capacitors.
B)They are quite popular due to their small size and weight as well as output.
C)They function with low-power supply sources.
D)The final kVp is variable as a function of exposure time.
Question
Mobile examinations are difficult to accomplish because

A)mobile equipment exposure techniques are dependent upon hospital power.
B)stationary equipment is more reliable.
C)exam conditions can vary widely.
D)most patients are unconscious.
Question
Radiographers should move ____ away from the patient prior to making an exposure.

A)1 foot
B)2 feet
C)2 yards
D)none of the above
Question
Output from battery-operated units is essentially

A)single-phase unrectified.
B)single-phase, fully rectified.
C)three-phase, 6 pulse.
D)high frequency.
Question
Mobile examinations may require

A)special adaptations of routine projections.
B)imaginative equipment manipulation.
C)innovative technical factor considerations.
D)all of the above
Question
With current, state-of-the-art portable units,

A)kVp is used to compensate for insufficient mAs.
B)it is safe to stand behind the unit for protection.
C)the batteries provide power for exposures and travel.
D)higher ratio grids are necessary.
Question
Before entering a surgical suite, who must be consulted?

A)the unit receptionist
B)the attending physician
C)the surgical technician
D)any of the above
Question
Match the following items with the correct statement as they relate to mobile radiography.
unpopular and nearly obsolete type of generator for mobile units

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
Match the following items with the correct statement as they relate to mobile radiography.
x-ray beam quality with current-day portable units

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
Match the following items with the correct statement as they relate to mobile radiography.
digital receptor with electrical cord

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
If a chest radiograph requires 4 mAs at 72", the new mAs to use at 56" would be

A)3 mAs.
B)2.4 mAs.
C)2.0 mAs.
D)1.5 mAs.
Question
Match the following items with the correct statement as they relate to mobile radiography.
should be repositioned after consulting a nurse or physician

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
If the radiographer is unable to achieve a 72" SID during mobile chest radiography, an alternative distance to use is

A)40".
B)48".
C)56".
D)60".
Question
Batteries used in mobile radiographic machines

A)are rechargeable.
B)provide power for mobility only.
C)recharge using 220-240 V AC power.
D)all of the above
Question
Match the following items with the correct statement as they relate to mobile radiography.
convenient SID for mobile radiography

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
All of the following features are essential to a mobile radiographic unit EXCEPT

A)expandable 6-foot exposure cord.
B)automatic exposure control with single field.
C)dead-man type exposure switch.
D)clear display of exposure factors.
Question
Match the following items with the correct statement as they relate to mobile radiography.
first to develop a portable unit

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
The preferred method for demonstrating air fluid levels during mobile radiography is to make sure that the

A)SID is 60".
B)patient is sitting fully erect.
C)x-ray beam is perpendicular to the receptor.
D)both b and c
Question
Match the following items with the correct statement as they relate to mobile radiography.
typical power source for recharging batteries

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
Match the following items with the correct statement as they relate to mobile radiography.
preferred radiographic grid characteristics for mobile radiography

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Question
As you prepare to complete a portable chest radiograph on a patient with possible congestive heart failure, you notice several tubes and lines going into the patient.Prior to making the exposure, you should

A)adjust your kVp to penetrate the opacity of the lines.
B)ask a nurse to move the lines from the image area.
C)move the lines out of the image area and complete the exam, as time is critical with this type of patient.
D)both a and b
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/34
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 35: Mobile Radiography
1
During optimal mobile radiography of the chest, the recommended SID is ____ inches.

A)72
B)56
C)40
D)36
72
2
How many lead aprons should be carried to a mobile radiographic examination?

A)none; lead aprons are not necessary
B)one for the radiographer
C)one for the patient
D)two: one for the patient and one for the radiographer
two: one for the patient and one for the radiographer
3
The more advanced, full-power mobile units use ____ energy for a power supply.

A)solar
B)battery
C)thermal
D)alternating current
battery
4
Modern mobile radiographic units possess

A)a flat panel detector for image review.
B)disposable, single-use batteries.
C)a cabinet for film cassette storage.
D)remote exposure controls.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
5
Proper tube-grid alignment is important during ____ radiography.

A)mobile
B)stationary
C)portable
D)all of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
6
For mobile radiography, radiographic grids should have a

A)high ratio and low frequency.
B)low ratio and low frequency.
C)cross-hatch design.
D)low ratio and high frequency.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
7
During mobile radiography, it is the radiographer's responsibility to protect

A)the patient.
B)other health professionals.
C)the public.
D)all of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
8
During mobile radiography, the radiographer must achieve maximum distance primarily from the

A)patient.
B)mobile unit.
C)image receptor.
D)x-ray tube.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
9
In surgery or in the emergency unit, which situation should be considered?

A)the stress of performing in a high-tension environment
B)limitations due to aseptic conditions
C)the presence of additional critical equipment
D)all of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
10
During mobile radiography, it is the radiographer's responsibility to request that ____ leave the immediate area prior to exposure.

A)physicians
B)family members
C)health professionals
D)all of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
11
Which grid type would permit wide exposure and centering latitude and would therefore be preferred for mobile radiography?

A)6:1
B)8:1
C)10:1
D)12:1
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
12
When it is determined that air-fluid level demonstration is a priority, ____ projection(s) may be required for ____.

A)one; air-fluid levels
B)one; a normal projection of the chest
C)two; one AP and one lateral projection
D)two; air-fluid levels and a normal projection of the chest
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
13
A common cause for repeat examinations in mobile radiography is due to

A)equipment reliability.
B)angulation of grids and grid-off.
C)inaccurate SID measurements.
D)low image contrast.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
14
All of the following are true of capacitor-discharge units EXCEPT:

A)Their output is a function of large capacitors.
B)They are quite popular due to their small size and weight as well as output.
C)They function with low-power supply sources.
D)The final kVp is variable as a function of exposure time.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
15
Mobile examinations are difficult to accomplish because

A)mobile equipment exposure techniques are dependent upon hospital power.
B)stationary equipment is more reliable.
C)exam conditions can vary widely.
D)most patients are unconscious.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
16
Radiographers should move ____ away from the patient prior to making an exposure.

A)1 foot
B)2 feet
C)2 yards
D)none of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
17
Output from battery-operated units is essentially

A)single-phase unrectified.
B)single-phase, fully rectified.
C)three-phase, 6 pulse.
D)high frequency.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
18
Mobile examinations may require

A)special adaptations of routine projections.
B)imaginative equipment manipulation.
C)innovative technical factor considerations.
D)all of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
19
With current, state-of-the-art portable units,

A)kVp is used to compensate for insufficient mAs.
B)it is safe to stand behind the unit for protection.
C)the batteries provide power for exposures and travel.
D)higher ratio grids are necessary.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
20
Before entering a surgical suite, who must be consulted?

A)the unit receptionist
B)the attending physician
C)the surgical technician
D)any of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
21
Match the following items with the correct statement as they relate to mobile radiography.
unpopular and nearly obsolete type of generator for mobile units

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
22
Match the following items with the correct statement as they relate to mobile radiography.
x-ray beam quality with current-day portable units

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
23
Match the following items with the correct statement as they relate to mobile radiography.
digital receptor with electrical cord

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
24
If a chest radiograph requires 4 mAs at 72", the new mAs to use at 56" would be

A)3 mAs.
B)2.4 mAs.
C)2.0 mAs.
D)1.5 mAs.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
25
Match the following items with the correct statement as they relate to mobile radiography.
should be repositioned after consulting a nurse or physician

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
26
If the radiographer is unable to achieve a 72" SID during mobile chest radiography, an alternative distance to use is

A)40".
B)48".
C)56".
D)60".
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
27
Batteries used in mobile radiographic machines

A)are rechargeable.
B)provide power for mobility only.
C)recharge using 220-240 V AC power.
D)all of the above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
28
Match the following items with the correct statement as they relate to mobile radiography.
convenient SID for mobile radiography

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
29
All of the following features are essential to a mobile radiographic unit EXCEPT

A)expandable 6-foot exposure cord.
B)automatic exposure control with single field.
C)dead-man type exposure switch.
D)clear display of exposure factors.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
30
Match the following items with the correct statement as they relate to mobile radiography.
first to develop a portable unit

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
31
The preferred method for demonstrating air fluid levels during mobile radiography is to make sure that the

A)SID is 60".
B)patient is sitting fully erect.
C)x-ray beam is perpendicular to the receptor.
D)both b and c
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
32
Match the following items with the correct statement as they relate to mobile radiography.
typical power source for recharging batteries

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
33
Match the following items with the correct statement as they relate to mobile radiography.
preferred radiographic grid characteristics for mobile radiography

A)110-120 volts
B)capacitor discharge
C)Picker Corporation
D)high frequency output
E)56 inches
F)rechargeable batteries
G)tethered detector
H)low ratio and high frequency
I)dead man switch
J)CVP line
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
34
As you prepare to complete a portable chest radiograph on a patient with possible congestive heart failure, you notice several tubes and lines going into the patient.Prior to making the exposure, you should

A)adjust your kVp to penetrate the opacity of the lines.
B)ask a nurse to move the lines from the image area.
C)move the lines out of the image area and complete the exam, as time is critical with this type of patient.
D)both a and b
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 34 flashcards in this deck.