To engage the small focal spot in a dedicated mammography tube, ____ focusing must be used.

A)convex
B)dual
C)biased
D)concave
Use Space or
up arrow
down arrow
to flip the card.
Question
In mammography, the kVp commonly used in clinical practice varies between ____ kVp.

A)25 and 28
B)30 and 34
C)35 and 40
D)55 and 60
Question
Which organization offers a voluntary accreditation program for mammography?

A)JRCERT
B)ACR
C)NRC
D)ASRT
Question
Breast tissue is made up of

A)fatty tissue.
B)glandular tissue.
C)fibrous tissue.
D)all of the above
Question
The majority of mammography machines utilize a ____ inch SID.

A)24 to 30
B)30 to 36
C)36 to 40
D)60 to 72
Question
The disadvantage to using low kVp in mammography is its ability to produce

A)a very low-energy x-ray beam.
B)high radiographic contrast.
C)a soft x-ray beam.
D)an increased patient dose.
Question
The anode material of choice for a mammography machine is

A)lead.
B)tungsten.
C)molybdenum.
D)none of the above
Question
Dedicated mammography machines use ____ generators.

A)falling-load
B)single-phase, high frequency
C)capacitor discharge
D)three-phase
Question
The port of the x-ray tube in mammography is composed of

A)barium.
B)rhodium.
C)molybdenum.
D)beryllium.
Question
Approximately 40% of cancers in the breast contain microcalcifications that have an atomic number of

A)2
B)20
C)50
D)100
Question
The advantage to using low kVp in mammography is its ability to produce

A)a very low-energy x-ray beam.
B)high radiographic contrast.
C)a soft x-ray beam.
D)all of the above
Question
A disadvantage of using molybdenum for the anode material in mammography tubes is

A)less x-ray photon output.
B)increased mAs required to maintain film density.
C)increased patient dose.
D)all of the above
Question
The AEC system on most mammography machines utilizes ____ radiation-sensitive detector(s) located ____ the cassette.

A)a single; in front of
B)three; in front of
C)a single; behind
D)three; behind
Question
The type of generators used in dedicated mammography machines allows very precise control of

A)kVp.
B)mA.
C)time.
D)all of the above
Question
When the backup time is reached during a breast exposure, the radiographer should select a ____ setting for the repeat radiograph.

A)lower mAs
B)higher mAs
C)higher kVp
D)lower kVp
Question
Presently, the only radiography examination fully regulated by the federal government is

A)angiography.
B)fluoroscopy.
C)mammography.
D)CT scanning.
Question
The prominent heel effect in mammography is the result of a

A)narrow target angle.
B)wide target angle.
C)larger cathode.
D)smaller cathode.
Question
The prominent heel effect in mammography is due to a

A)short SID.
B)short OID.
C)long SOD.
D)long OID.
Question
Magnification projections of the breast provide

A)increased resolution.
B)a reduction in scatter radiation.
C)improved visibility of detail.
D)all of the above
Question
The advantage of using molybdenum for the anode material in mammography tubes is

A)a decreased number of low-energy photons.
B)low radiographic contrast.
C)production of specific x-ray energies.
D)none of the above
Question
Match the following items with the correct statement as each relates to mammographic imaging.
25-28

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Mammography grids are

A)linear.
B)moving.
C)very low ratio.
D)all of the above
Question
Match the following items with the correct statement as each relates to mammographic imaging.
preferred filter material

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Match the following items with the correct statement as each relates to mammographic imaging.
digital tomosynthesis

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Match the following items with the correct statement as each relates to mammographic imaging.
24-30 inches

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Breast compression

A)provides a more uniform film density.
B)improves visualization.
C)reduces magnification.
D)all of the above
Question
Digital tomosynthesis in mammography

A)uses a 40-degree rotation angle.
B)acquires ten images of the breast per sweep.
C)uses digital detector technology.
D)all of the above
Question
Match the following items with the correct statement as each relates to mammographic imaging.
preferred energy range of x-ray photons

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
The inherent low subject contrast of breast tissue requires that we attempt to optimize

A)the photoelectric effect.
B)the use of high ratio grids.
C)the Compton effect.
D)aluminum filtration.
Question
The use of a grid in mammography

A)improves radiographic quality.
B)increases patient exposure.
C)reduces scatter reaching the film.
D)all of the above
Question
Match the following items with the correct statement as each relates to mammographic imaging.
Xerox

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Breast compression

A)reduces magnification.
B)increases tissue thickness.
C)increases radiation exposure.
D)increases motion unsharpness.
Question
Mammography x-ray tubes

A)are tilted to place the central ray at chest wall.
B)use stationary anodes for better resolution.
C)have higher heat capacity than radiographic tubes.
D)have a 0.6 mm large focal spot.
Question
Match the following items with the correct statement as each relates to mammographic imaging.
recommended for dense breasts

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Match the following items with the correct statement as each relates to mammographic imaging.
introduced the first dedicated mammography system

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
To cover a 24x30 cm receptor in mammography, the mammography x-ray tube

A)uses molybdenum as the anode material.
B)possesses a beryllium filter.
C)has an effective target angle of 22 to 24 degrees.
D)adjusts field size with compression.
Question
Breast compression is applied at ____ pounds of force.

A)1 to 5
B)5 to 20
C)25 to 45
D)50 to 60
Question
Match the following items with the correct statement as each relates to mammographic imaging.
optimizes mammography services nationwide

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
Match the following items with the correct statement as each relates to mammographic imaging.
uses a 0.1 mm focal spot

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Question
One of the principal advantages of digital mammography is

A)the capacity to manipulate the image's contrast and density.
B)the capacity to transmit images for consultation, teaching, etc.
C)archiving (PACS) for simplified storage and ready access of images.
D)all of the above
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/40
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 38: Mammography
1
To engage the small focal spot in a dedicated mammography tube, ____ focusing must be used.

A)convex
B)dual
C)biased
D)concave
biased
2
In mammography, the kVp commonly used in clinical practice varies between ____ kVp.

A)25 and 28
B)30 and 34
C)35 and 40
D)55 and 60
25 and 28
3
Which organization offers a voluntary accreditation program for mammography?

A)JRCERT
B)ACR
C)NRC
D)ASRT
ACR
4
Breast tissue is made up of

A)fatty tissue.
B)glandular tissue.
C)fibrous tissue.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
5
The majority of mammography machines utilize a ____ inch SID.

A)24 to 30
B)30 to 36
C)36 to 40
D)60 to 72
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
6
The disadvantage to using low kVp in mammography is its ability to produce

A)a very low-energy x-ray beam.
B)high radiographic contrast.
C)a soft x-ray beam.
D)an increased patient dose.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
7
The anode material of choice for a mammography machine is

A)lead.
B)tungsten.
C)molybdenum.
D)none of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
8
Dedicated mammography machines use ____ generators.

A)falling-load
B)single-phase, high frequency
C)capacitor discharge
D)three-phase
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
9
The port of the x-ray tube in mammography is composed of

A)barium.
B)rhodium.
C)molybdenum.
D)beryllium.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
10
Approximately 40% of cancers in the breast contain microcalcifications that have an atomic number of

A)2
B)20
C)50
D)100
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
11
The advantage to using low kVp in mammography is its ability to produce

A)a very low-energy x-ray beam.
B)high radiographic contrast.
C)a soft x-ray beam.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
12
A disadvantage of using molybdenum for the anode material in mammography tubes is

A)less x-ray photon output.
B)increased mAs required to maintain film density.
C)increased patient dose.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
13
The AEC system on most mammography machines utilizes ____ radiation-sensitive detector(s) located ____ the cassette.

A)a single; in front of
B)three; in front of
C)a single; behind
D)three; behind
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
14
The type of generators used in dedicated mammography machines allows very precise control of

A)kVp.
B)mA.
C)time.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
15
When the backup time is reached during a breast exposure, the radiographer should select a ____ setting for the repeat radiograph.

A)lower mAs
B)higher mAs
C)higher kVp
D)lower kVp
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
16
Presently, the only radiography examination fully regulated by the federal government is

A)angiography.
B)fluoroscopy.
C)mammography.
D)CT scanning.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
17
The prominent heel effect in mammography is the result of a

A)narrow target angle.
B)wide target angle.
C)larger cathode.
D)smaller cathode.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
18
The prominent heel effect in mammography is due to a

A)short SID.
B)short OID.
C)long SOD.
D)long OID.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
19
Magnification projections of the breast provide

A)increased resolution.
B)a reduction in scatter radiation.
C)improved visibility of detail.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
20
The advantage of using molybdenum for the anode material in mammography tubes is

A)a decreased number of low-energy photons.
B)low radiographic contrast.
C)production of specific x-ray energies.
D)none of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
21
Match the following items with the correct statement as each relates to mammographic imaging.
25-28

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
22
Mammography grids are

A)linear.
B)moving.
C)very low ratio.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
23
Match the following items with the correct statement as each relates to mammographic imaging.
preferred filter material

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
24
Match the following items with the correct statement as each relates to mammographic imaging.
digital tomosynthesis

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
25
Match the following items with the correct statement as each relates to mammographic imaging.
24-30 inches

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
26
Breast compression

A)provides a more uniform film density.
B)improves visualization.
C)reduces magnification.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
27
Digital tomosynthesis in mammography

A)uses a 40-degree rotation angle.
B)acquires ten images of the breast per sweep.
C)uses digital detector technology.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
28
Match the following items with the correct statement as each relates to mammographic imaging.
preferred energy range of x-ray photons

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
29
The inherent low subject contrast of breast tissue requires that we attempt to optimize

A)the photoelectric effect.
B)the use of high ratio grids.
C)the Compton effect.
D)aluminum filtration.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
30
The use of a grid in mammography

A)improves radiographic quality.
B)increases patient exposure.
C)reduces scatter reaching the film.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
31
Match the following items with the correct statement as each relates to mammographic imaging.
Xerox

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
32
Breast compression

A)reduces magnification.
B)increases tissue thickness.
C)increases radiation exposure.
D)increases motion unsharpness.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
33
Mammography x-ray tubes

A)are tilted to place the central ray at chest wall.
B)use stationary anodes for better resolution.
C)have higher heat capacity than radiographic tubes.
D)have a 0.6 mm large focal spot.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
34
Match the following items with the correct statement as each relates to mammographic imaging.
recommended for dense breasts

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
35
Match the following items with the correct statement as each relates to mammographic imaging.
introduced the first dedicated mammography system

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
36
To cover a 24x30 cm receptor in mammography, the mammography x-ray tube

A)uses molybdenum as the anode material.
B)possesses a beryllium filter.
C)has an effective target angle of 22 to 24 degrees.
D)adjusts field size with compression.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
37
Breast compression is applied at ____ pounds of force.

A)1 to 5
B)5 to 20
C)25 to 45
D)50 to 60
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
38
Match the following items with the correct statement as each relates to mammographic imaging.
optimizes mammography services nationwide

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
39
Match the following items with the correct statement as each relates to mammographic imaging.
uses a 0.1 mm focal spot

A)beryllium
B)tungsten
C)optimum kVp range
D)magnification imaging
E)microcalcifications
F)molybdenum
G)17-20 kev
H)Companie Generale de Radiographique
I)mammography SID
J)developed a dry process for mammography
K)rhodium
L)MQSA
M)NEXT
N)expected to become the mammography “gold standard”
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
40
One of the principal advantages of digital mammography is

A)the capacity to manipulate the image's contrast and density.
B)the capacity to transmit images for consultation, teaching, etc.
C)archiving (PACS) for simplified storage and ready access of images.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 40 flashcards in this deck.