Deck 41: Computed Tomography
1
Computed tomography sections are available as
A)coronal.
B)transverse.
C)sagittal.
D)all of the above
A)coronal.
B)transverse.
C)sagittal.
D)all of the above
all of the above
2
The CT radiation beam is collimated
A)at the tube exit.
B)at the detector entrance.
C)pre-patient and post-patient.
D)all of the above
A)at the tube exit.
B)at the detector entrance.
C)pre-patient and post-patient.
D)all of the above
all of the above
3
The localization image produced by the CT scanner is technically called a/an
A)volume rendered image.
B)scout film.
C)scanogram.
D)FOV image.
A)volume rendered image.
B)scout film.
C)scanogram.
D)FOV image.
scanogram.
4
A series of tissue density values that evolved for CT measurements is called ____ units.
A)Hounsfield
B)H & D
C)attenuation
D)iterative
A)Hounsfield
B)H & D
C)attenuation
D)iterative
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
5
The ____ is how well the detectors receive photons from the patient.
A)capture efficiency
B)absorption efficiency
C)conversion efficiency
D)response time
A)capture efficiency
B)absorption efficiency
C)conversion efficiency
D)response time
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
6
To achieve coronal or sagittal sections,
A)the gantry is repositioned.
B)the patient is repositioned.
C)reconfiguration software is implemented.
D)none of the above
A)the gantry is repositioned.
B)the patient is repositioned.
C)reconfiguration software is implemented.
D)none of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
7
The CT console provides the radiographer access to
A)the software program.
B)data acquisition.
C)data display.
D)all of the above
A)the software program.
B)data acquisition.
C)data display.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
8
Modern pulsed CT scanners operate at
A)120 kVp.
B)1 to 5 msec. pulses.
C)up to 1,000 mA.
D)all of the above
A)120 kVp.
B)1 to 5 msec. pulses.
C)up to 1,000 mA.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
9
The most recent generation of CT scanners use a ____ motion.
A)translate-rotate
B)helical
C)linear
D)elliptical
A)translate-rotate
B)helical
C)linear
D)elliptical
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
10
Contemporary CT scanners use solid state detectors.These detectors utilize
A)sodium iodide crystals.
B)rare earth ceramic scintillators.
C)xenon gas.
D)freon gas.
A)sodium iodide crystals.
B)rare earth ceramic scintillators.
C)xenon gas.
D)freon gas.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
11
The resolution of the CT image depends on the
A)pixel.
B)voxel.
C)matrix size.
D)all of the above
A)pixel.
B)voxel.
C)matrix size.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
12
The CT table is
A)made of carbon graphite.
B)rated for maximum weight.
C)motor-driven.
D)all of the above
A)made of carbon graphite.
B)rated for maximum weight.
C)motor-driven.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
13
The process of combining detector elements into various combinations in order set slice thickness is called detector
A)modulation.
B)dose efficiency.
C)binning.
D)interpolation.
A)modulation.
B)dose efficiency.
C)binning.
D)interpolation.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
14
First-generation CT scanners scanned the ____ only.
A)head
B)thorax
C)abdomen
D)pelvis
A)head
B)thorax
C)abdomen
D)pelvis
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
15
The smaller the scan field size, the
A)better the resolution.
B)faster the scan time.
C)less the risk of motion.
D)all of the above
A)better the resolution.
B)faster the scan time.
C)less the risk of motion.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
16
The CT radiographer usually varies the ____ to control the primary beam.
A)mA
B)time
C)kVp
D)distance
A)mA
B)time
C)kVp
D)distance
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
17
The gantry of the CT unit contains the
A)post-processing workstation.
B)operator's interface.
C)x-ray tube.
D)all of the above
A)post-processing workstation.
B)operator's interface.
C)x-ray tube.
D)all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
18
The ____ is determined by how well the detector converts the absorbed photon information to a digital signal for the computer.
A)capture efficiency
B)absorption efficiency
C)conversion efficiency
D)response time
A)capture efficiency
B)absorption efficiency
C)conversion efficiency
D)response time
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
19
The ____ is how well the detectors convert incoming photons.
A)capture efficiency
B)absorption efficiency
C)conversion efficiency
D)response time
A)capture efficiency
B)absorption efficiency
C)conversion efficiency
D)response time
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
20
A ____ artifact is caused by motion.
A)beam-hardening
B)ring
C)star
D)streak
A)beam-hardening
B)ring
C)star
D)streak
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
21
If the table is moving at 10 mm/sec., and a section thickness of 8 mm is being acquired, what is the pitch?
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
22
The CTDI dose measurement
A)is slice-based.
B)takes into account the total amount of irradiated tissue.
C)represents the average total dose to the patient during the examination.
D)measures entrance skin exposure (ESE).
A)is slice-based.
B)takes into account the total amount of irradiated tissue.
C)represents the average total dose to the patient during the examination.
D)measures entrance skin exposure (ESE).
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
23
If the table is moving at 5 mm/sec., and a pitch of 0.8 is being used, what is the section thickness?
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
24
CT image data is acquired in the
A)coronal plane and reconstructed in the axial plane .
B)transverse plane and reconstructed in any plane.
C)sagittal plane .
D)axial plane and reconstructed in the coronal plane.
A)coronal plane and reconstructed in the axial plane .
B)transverse plane and reconstructed in any plane.
C)sagittal plane .
D)axial plane and reconstructed in the coronal plane.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
25
The range of CT numbers or Hounsfield Units varies from
A)100 to 300.
B)-100 to +300.
C)-1000 to +3000.
D)1000 to +3000.
A)100 to 300.
B)-100 to +300.
C)-1000 to +3000.
D)1000 to +3000.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
26
If the table is moving at 12 mm/sec., and a section thickness of 10 mm is being acquired, what is the pitch?
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
27
As noise increases in a CT image,
A)low contrast resolution increases.
B)dose to the patient increases.
C)low contrast resolution decreases.
D)both a and c
A)low contrast resolution increases.
B)dose to the patient increases.
C)low contrast resolution decreases.
D)both a and c
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
28
The process of modifying pixel values by a mathematical formula is called
A)convolution.
B)deconvolution.
C)calculus.
D)interpolation.
A)convolution.
B)deconvolution.
C)calculus.
D)interpolation.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
29
In order for a CT x-ray photon to be measured, it must
1)enter the detector
2)be absorbed by the detector material
3)transmit through the detector to be back-projected
4)have sufficient energy to undergo a Compton interaction
5)be converted to light and then electrical energy as a signal
A)1, 3, 4, and 5
B)1, 2, and 5
C)1, 2, and 4
D)1, 4, and 5
1)enter the detector
2)be absorbed by the detector material
3)transmit through the detector to be back-projected
4)have sufficient energy to undergo a Compton interaction
5)be converted to light and then electrical energy as a signal
A)1, 3, 4, and 5
B)1, 2, and 5
C)1, 2, and 4
D)1, 4, and 5
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
30
A ____ artifact is caused by detector error.
A)beam-hardening
B)ring
C)star
D)streak
A)beam-hardening
B)ring
C)star
D)streak
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
31
The primary mathematical method used in the creation of computerized medical images is the ____ transformation.
A)interpolation
B)Hounsfield
C)algorithm
D)Fourier
A)interpolation
B)Hounsfield
C)algorithm
D)Fourier
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
32
The calculation of CT numbers is based upon the calculation of
A)half-value layers.
B)half-lives.
C)attenuation coefficients.
D)pitch.
A)half-value layers.
B)half-lives.
C)attenuation coefficients.
D)pitch.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
33
MSCT scanners have evolved greatly over the last few years, particularly with regard to slice combinations, scanning speed, and clinical utility.As these scanners gather more slices of data per rotation, a major technological challenge is
A) the amount of data handled by the computer.
B) the number of images to be analyzed by the clinician.
C) developing technologies to minimize dose.
D) all of the above
A) the amount of data handled by the computer.
B) the number of images to be analyzed by the clinician.
C) developing technologies to minimize dose.
D) all of the above
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
34
CT scan pitch uses all of the following technical parameters EXCEPT
A)slice thickness.
B)360-degree gantry rotation.
C)acquisition mAs .
D)table increment.
A)slice thickness.
B)360-degree gantry rotation.
C)acquisition mAs .
D)table increment.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
35
A ____ artifact is caused by attenuation of the beam as it passes through the patient.
A)beam-hardening
B)ring
C)star
D)streak
A)beam-hardening
B)ring
C)star
D)streak
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
36
With MSCT scanners, resolution is primarily determined by
A) prepatient collimation.
B) dose.
C) collimation at the detector.
D) gantry rotation speed.
A) prepatient collimation.
B) dose.
C) collimation at the detector.
D) gantry rotation speed.
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
37
If the table is moving at 5 mm/sec., and a pitch of 1.5 is being used, what is the section thickness?
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
38
If a pitch of 1.0 is being used with a section thickness of 8 mm, what is the proper table speed?
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
39
If a pitch of 0.5 is being used with a section thickness of 10 mm, what is the proper table speed?
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck
40
A ____ artifact is caused by the presence of metal in the patient.
A)beam-hardening
B)ring
C)star
D)streak
A)beam-hardening
B)ring
C)star
D)streak
Unlock Deck
Unlock for access to all 40 flashcards in this deck.
Unlock Deck
k this deck