Deck 7: Fire and Smoke-Related Properties

Full screen (f)
exit full mode
Question
Among the various types of construction included in a building code, which is the most fire- resistive type?

A)Type HT
B)Type V(A)
C)Type V(B)
D)Type I(A)
E)None of the above
Use Space or
up arrow
down arrow
to flip the card.
Question
Noncombustible/combustible types of construction are

A)Types 1 and 2.
B)Types V and VI.
C)Types III and IV.
D)Types I and II.
E)Types 1, 2, and 3.
Question
Based on the statistics of fatalities in building fires in the United States, which building type has the worst record?

A)Hotel buildings
B)Industrial buildings
C)Multifamily dwellings
D)One- and two- family dwellings
E)Office buildings
Question
Combustible types of construction are

A)Type VI.
B)Type V.
C)Types 4 and 5.
D)Types 4, 5, and 6.
E)Types IV, V, and VI.
Question
Noncombustible types of construction are

A)Types 1, 2, and 3.
B)Type I.
C)Types I and II.
D)Types III and IV.
E)Types 1 and 2.
Question
The total number of types of construction, including their sub- classifications, in a building code is

A)6)
B)7)
C)8)
D)9)
E)10.
Question
The design of the means- of- egress system in a building is a part of

A)passive fire protection.
B)upgraded fire protection.
C)basic fire protection.
D)active fire protection.
E)none of the above.
Question
Fire detection system in a building is a part of

A)upgraded fire protection.
B)basic fire protection.
C)passive fire protection.
D)active fire protection.
E)none of the above.
Question
Statistics based on autopsies conducted on people who died in building fires indicate that most deaths occur due to

A)emotional shock.
B)smoke.
C)burns.
D)heart failure.
Question
The automatic sprinkler system in a building is a part of

A)basic fire protection
B)active fire protection.
C)upgraded fire protection
D)passive fire protection.
E)none of the above.
Question
Fire- resistance rating of building assemblies is generally obtained from fire tests, not through calculations.
Question
The fire code is one of the most important chapters in a building code.
Question
Based on ASTM E136 test, fire- retardant- treated (FRT)wood is a

A)combustible/noncombustible material and hence it can be used in assemblies where the use of noncombustible materials is mandated.
B)noncombustible material.
C)combustible material and hence it cannot be used in assemblies where the use of noncombustible materials is mandated.
D)combustible material but is allowed to be used in several assemblies where the use of noncombustible materials is mandated.
E)none of the above.
Question
Fire- resistance rating is a property of

A)the total thickness of assembly.
B)the assembly as a whole.
C)the material of which the assembly is made.
D)the materials and the weight of assembly.
E)none of the above.
Question
Building codes divide the types of construction into

A)Types I to VI.
B)Types 1 to 5.
C)Types 1 to 6.
D)Types I to V.
E)none of the above.
Question
Fire- resistance rating of an assembly is measured in units of

A)total heat released by assembly in fire test.
B)pounds per square inch.
C)time.
D)rate of temperature increase of assembly during fire test.
E)none of the above.
Question
In which type(s)of construction, the exterior nonbearing walls must be of noncombustible materials?

A)Type IV(C)
B)Type IV(A)and Type IV(B)
C)Type V(B)
D)Type V(A)
E)All types except Type V(A)and Type V(B)
Question
In determining the fire- resistance rating of an assembly through ASTM E119 test, which of the following properties of the assembly are investigated?

A)Structural integrity during the fire
B)Change of color of assembly during the fire
C)Occurrence of cracks in assembly during the fire
D)(a)and (b)
E)(a)and (c)
Question
Which type of construction is commonly used in a typical single- family dwelling in the United States?

A)Type II(B)
B)Type IV
C)Type II(A)
D)Type V(B)
E)Type V(A)
Question
A material whose core is noncombustible but is covered with a combustible lamination or paint is considered a noncombustible material, provided that the thickness of the paint or lamination does not exceed

A)1/8 in.
B)1/16 in.
C)1 in.
D)1/2 in.
E)1/4 in.
Question
In terms of fire- related fatalities in buildings in the U.S., which of the two building types is more vulnerable:
(i)Residential buildings or non- residential buildings?
(ii)One- and two- family dwellings or multifamily residential buildings?
Question
FSI of cement board is

A)20.
B)zero.
C)200.
D)50.
E)100.
Question
What is the essential difference between the building code and the fire code of a city?
Question
Based on their fire properties, interior finishes are divided into

A)Classes I, II, III, and IV.
B)Classes W, X, Y, and Z.
C)Classes A, B, C, and D.
D)Classes A, B, and
E)Classes X, Y, and Z.
Question
A fire wall must be constructed of noncombustible materials with no exceptions.
Question
Describe what constitutes passive fire protection in buildings.
Question
A fire barrier refers to a

A)fire- rated wall.
B)fire- rated floor.
C)fire- rated roof.
D)all of the above.
E)none of the above.
Question
The exit access corridor walls in most occupancies need not be fire rated if the building is provided with automatic sprinklers throughout.
Question
Which building code provision deals with fire- safe maintenance of buildings after its occupancy?
Question
The walls enclosing an exit stair are generally designed as

A)fire walls.
B)fire partitions.
C)fire barriers.
D)any one of the above.
E)none of the above.
Question
A fire wall divides a building into two parts in such a way that

A)if the automatic sprinklers have been installed in one part, it is as if they have been installed in both parts.
B)the two parts behave as two separate buildings so that if one part burns down and collapses along with the fire wall, the other part will remain intact.
C)the aggregate area of each part is the same.
D)the occupant load in each part is the same.
E)the two parts behave as two separate buildings so that if one part burns down and collapses, the other part and the fire wall will remain intact.
Question
SDI measures

A)toxicity of smoke.
B)visibility through smoke.
C)rate of smoke generation.
D)amount of carbon dioxide in smoke.
E)none of the above.
Question
In broad terms, there are two ways to provide fire protection in buildings. Name them.
Question
The maximum value of SDI recognized by building codes is

A)50.
B)150.
C)300.
D)450.
E)none of the above.
Question
A rectangular area of building that is bounded on all three sides by exterior walls, on the fourth side by a fire barrier, and with fire- rated floors above and below, may be treated as a fire area.
Question
The spread of flames on floor finishes is ignored.
Question
The term firestop refers to

A)a fire- rated floor with a minimum fire rating of 3 h.
B)a fire- rated wall with a minimum fire rating of 3 h.
C)a fire seal in a non- fire- rated wall or floor.
D)a fire seal in a fire- rated wall or floor.
E)none of the above.
Question
The term FSI refers to

A)fire and smoke index.
B)fire- speed index.
C)flame- spread index.
D)fire safety index.
Question
The fire properties that determine the class of interior finishes are

A)fire- resistance rating and FSI.
B)fire- resistance rating, FSI, and SDI.
C)fire- resistance rating and SDI.
D)FSI and SDI.
Question
Describe what constitutes active fire protection in buildings.
Question
If a material passes ASTM E136 test, qualifying it as a noncombustible material, does it mean that it will perform better than a combustible material in a building fire? Explain.
Question
Name two commonly referenced publications for obtaining the fire ratings of frequently used building assemblies.
Question
The nine types of construction in the International Building Code are divided into three groups: (i)noncombustible group, (ii)combustible group, and (iii)noncombustible/combustible group. Name the types of construction in combustible group.
Question
When determining the fire rating of an assembly through laboratory testing, is the test specimen scaled half full- size, quarter full- size or some other size?
Question
Is the fire rating of non- load- bearing walls (i.e., partition walls)a determinant for the type of construction of a building?
Question
Which factor determines the type of construction of a building?
Question
The building codes permit the use of fire- retardant- treated (FRT)wood or FRT plywood in some situations where noncombustible materials are required, although both these materials are not recognized by codes as noncombustible materials. Explain the reasons.
Question
Why is gypsum board recognized as a noncombustible material by the codes although it has paper lining on both sides, which is a combustible material?
Question
The nine types of construction in the International Building Code are divided into three groups: (i)noncombustible group, (ii)combustible group, and (iii)noncombustible/combustible group. Name the types of construction in the noncombustible group.
Question
The International Building Code classifies buildings into nine types of construction. Name them.
Question
The International Building Code classifies types of construction into three groups based on the requirement for the use of combustible or noncombustible materials. What is the requirement for the noncombustible group?
Question
The International Building Code classifies types of construction into three groups based on the requirement for the use of combustible or noncombustible materials. What is the requirement for the noncombustible/combustible group?
Question
The International Building Code classifies types of construction into three groups based on the requirement for the use of combustible or noncombustible materials. What is the requirement for the combustible group?
Question
In determining the fire rating of an assembly through laboratory testing, an important criterion to meet is that it should maintain its structural integrity for the duration of its fire rating. What other criterion/criteria should the assembly satisfy during that duration?
Question
Give one example where fire- retardant- treated (FRT)wood or FRT plywood is permitted by the codes as substitute for noncombustible materials.
Question
A fire creates heat and smoke in buildings. Although both-high temperature and smoke-are deadly, which of the two contributes more to human fatalities?
Question
The nine types of construction in the International Building Code are divided into three groups: (i)noncombustible group, (ii)combustible group, and (iii)noncombustible/combustible group. Name the types of construction in noncombustible/combustible group.
Question
Name the quantity that measures the fire endurance of an assembly and give its units.
Question
Is fire endurance a material property or an assembly property?
Question
Is the fire rating of an assembly determined through calculations or laboratory testing?
Question
Using a sketch and notes, explain how the fire- resistance rating of an assembly is determined using ASTM standard E119.
Question
What does the acronym NFPA stand for?
Question
List the three groups into which the types of construction of buildings are divided based on whether the materials used in assemblies are combustible or noncombustible.
Question
The International Building Code classifies interior finishes as Class A, Class B, and Class C. Which material property(ies)are these classes based on?
Question
List two materials commonly used to increase the fire rating of an assembly.
Question
List the factors that affect fire safety in buildings.
Question
Describe the differences between Class A, Class B, and Class C interior finishes based on FSI and SDI.
Question
The required minimum fire ratings of various assemblies in Type III(A)and Type IV are essentially the same. What is the difference between these two types of construction?
Question
What is the type of construction of the building of Problem 8 if the floor's fire rating is 2 h, while all else remain unchanged?
Question
What does smoke developed index (SDI)mean? Does SDI apply to a material or an assembly?
Question
Explain why we need a test standard to determine whether a building material is combustible or noncombustible when we generally know which material is combustible and which is noncombustible.
Question
List the building assemblies that determine the type of construction classification of a building.
Question
The exterior walls of a building may pose a fire hazard to the adjacent building within the same lot or across the property line. Therefore, an exterior wall's minimum required fire rating is a function of its distance from the adjacent building, defined as fire separation distance (FSD)by the International Building Code. What is the required minimum value of FSD for a non- load- bearing wall (such as a glass curtain wall)so that the wall's fire rating may be zero?
Question
What is the difference between Type III(A)and Type IV construction? Explain.
Question
What does flame spread index (FSI)mean? Does FSI apply to a material or an assembly?
Question
Which type of construction is commonly used for single- family dwellings in the U.S.?
Question
Using a sketch and notes, explain what a fire wall is.
Question
Discuss the differences between a fire code and a building code.
Question
What is a fire wall?
Question
Which is more fire safe-FSI = 10, or FSI = 50?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/84
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 7: Fire and Smoke-Related Properties
1
Among the various types of construction included in a building code, which is the most fire- resistive type?

A)Type HT
B)Type V(A)
C)Type V(B)
D)Type I(A)
E)None of the above
D
2
Noncombustible/combustible types of construction are

A)Types 1 and 2.
B)Types V and VI.
C)Types III and IV.
D)Types I and II.
E)Types 1, 2, and 3.
C
3
Based on the statistics of fatalities in building fires in the United States, which building type has the worst record?

A)Hotel buildings
B)Industrial buildings
C)Multifamily dwellings
D)One- and two- family dwellings
E)Office buildings
D
4
Combustible types of construction are

A)Type VI.
B)Type V.
C)Types 4 and 5.
D)Types 4, 5, and 6.
E)Types IV, V, and VI.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
5
Noncombustible types of construction are

A)Types 1, 2, and 3.
B)Type I.
C)Types I and II.
D)Types III and IV.
E)Types 1 and 2.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
6
The total number of types of construction, including their sub- classifications, in a building code is

A)6)
B)7)
C)8)
D)9)
E)10.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
7
The design of the means- of- egress system in a building is a part of

A)passive fire protection.
B)upgraded fire protection.
C)basic fire protection.
D)active fire protection.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
8
Fire detection system in a building is a part of

A)upgraded fire protection.
B)basic fire protection.
C)passive fire protection.
D)active fire protection.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
9
Statistics based on autopsies conducted on people who died in building fires indicate that most deaths occur due to

A)emotional shock.
B)smoke.
C)burns.
D)heart failure.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
10
The automatic sprinkler system in a building is a part of

A)basic fire protection
B)active fire protection.
C)upgraded fire protection
D)passive fire protection.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
11
Fire- resistance rating of building assemblies is generally obtained from fire tests, not through calculations.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
12
The fire code is one of the most important chapters in a building code.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
13
Based on ASTM E136 test, fire- retardant- treated (FRT)wood is a

A)combustible/noncombustible material and hence it can be used in assemblies where the use of noncombustible materials is mandated.
B)noncombustible material.
C)combustible material and hence it cannot be used in assemblies where the use of noncombustible materials is mandated.
D)combustible material but is allowed to be used in several assemblies where the use of noncombustible materials is mandated.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
14
Fire- resistance rating is a property of

A)the total thickness of assembly.
B)the assembly as a whole.
C)the material of which the assembly is made.
D)the materials and the weight of assembly.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
15
Building codes divide the types of construction into

A)Types I to VI.
B)Types 1 to 5.
C)Types 1 to 6.
D)Types I to V.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
16
Fire- resistance rating of an assembly is measured in units of

A)total heat released by assembly in fire test.
B)pounds per square inch.
C)time.
D)rate of temperature increase of assembly during fire test.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
17
In which type(s)of construction, the exterior nonbearing walls must be of noncombustible materials?

A)Type IV(C)
B)Type IV(A)and Type IV(B)
C)Type V(B)
D)Type V(A)
E)All types except Type V(A)and Type V(B)
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
18
In determining the fire- resistance rating of an assembly through ASTM E119 test, which of the following properties of the assembly are investigated?

A)Structural integrity during the fire
B)Change of color of assembly during the fire
C)Occurrence of cracks in assembly during the fire
D)(a)and (b)
E)(a)and (c)
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
19
Which type of construction is commonly used in a typical single- family dwelling in the United States?

A)Type II(B)
B)Type IV
C)Type II(A)
D)Type V(B)
E)Type V(A)
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
20
A material whose core is noncombustible but is covered with a combustible lamination or paint is considered a noncombustible material, provided that the thickness of the paint or lamination does not exceed

A)1/8 in.
B)1/16 in.
C)1 in.
D)1/2 in.
E)1/4 in.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
21
In terms of fire- related fatalities in buildings in the U.S., which of the two building types is more vulnerable:
(i)Residential buildings or non- residential buildings?
(ii)One- and two- family dwellings or multifamily residential buildings?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
22
FSI of cement board is

A)20.
B)zero.
C)200.
D)50.
E)100.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
23
What is the essential difference between the building code and the fire code of a city?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
24
Based on their fire properties, interior finishes are divided into

A)Classes I, II, III, and IV.
B)Classes W, X, Y, and Z.
C)Classes A, B, C, and D.
D)Classes A, B, and
E)Classes X, Y, and Z.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
25
A fire wall must be constructed of noncombustible materials with no exceptions.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
26
Describe what constitutes passive fire protection in buildings.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
27
A fire barrier refers to a

A)fire- rated wall.
B)fire- rated floor.
C)fire- rated roof.
D)all of the above.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
28
The exit access corridor walls in most occupancies need not be fire rated if the building is provided with automatic sprinklers throughout.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
29
Which building code provision deals with fire- safe maintenance of buildings after its occupancy?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
30
The walls enclosing an exit stair are generally designed as

A)fire walls.
B)fire partitions.
C)fire barriers.
D)any one of the above.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
31
A fire wall divides a building into two parts in such a way that

A)if the automatic sprinklers have been installed in one part, it is as if they have been installed in both parts.
B)the two parts behave as two separate buildings so that if one part burns down and collapses along with the fire wall, the other part will remain intact.
C)the aggregate area of each part is the same.
D)the occupant load in each part is the same.
E)the two parts behave as two separate buildings so that if one part burns down and collapses, the other part and the fire wall will remain intact.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
32
SDI measures

A)toxicity of smoke.
B)visibility through smoke.
C)rate of smoke generation.
D)amount of carbon dioxide in smoke.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
33
In broad terms, there are two ways to provide fire protection in buildings. Name them.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
34
The maximum value of SDI recognized by building codes is

A)50.
B)150.
C)300.
D)450.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
35
A rectangular area of building that is bounded on all three sides by exterior walls, on the fourth side by a fire barrier, and with fire- rated floors above and below, may be treated as a fire area.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
36
The spread of flames on floor finishes is ignored.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
37
The term firestop refers to

A)a fire- rated floor with a minimum fire rating of 3 h.
B)a fire- rated wall with a minimum fire rating of 3 h.
C)a fire seal in a non- fire- rated wall or floor.
D)a fire seal in a fire- rated wall or floor.
E)none of the above.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
38
The term FSI refers to

A)fire and smoke index.
B)fire- speed index.
C)flame- spread index.
D)fire safety index.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
39
The fire properties that determine the class of interior finishes are

A)fire- resistance rating and FSI.
B)fire- resistance rating, FSI, and SDI.
C)fire- resistance rating and SDI.
D)FSI and SDI.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
40
Describe what constitutes active fire protection in buildings.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
41
If a material passes ASTM E136 test, qualifying it as a noncombustible material, does it mean that it will perform better than a combustible material in a building fire? Explain.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
42
Name two commonly referenced publications for obtaining the fire ratings of frequently used building assemblies.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
43
The nine types of construction in the International Building Code are divided into three groups: (i)noncombustible group, (ii)combustible group, and (iii)noncombustible/combustible group. Name the types of construction in combustible group.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
44
When determining the fire rating of an assembly through laboratory testing, is the test specimen scaled half full- size, quarter full- size or some other size?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
45
Is the fire rating of non- load- bearing walls (i.e., partition walls)a determinant for the type of construction of a building?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
46
Which factor determines the type of construction of a building?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
47
The building codes permit the use of fire- retardant- treated (FRT)wood or FRT plywood in some situations where noncombustible materials are required, although both these materials are not recognized by codes as noncombustible materials. Explain the reasons.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
48
Why is gypsum board recognized as a noncombustible material by the codes although it has paper lining on both sides, which is a combustible material?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
49
The nine types of construction in the International Building Code are divided into three groups: (i)noncombustible group, (ii)combustible group, and (iii)noncombustible/combustible group. Name the types of construction in the noncombustible group.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
50
The International Building Code classifies buildings into nine types of construction. Name them.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
51
The International Building Code classifies types of construction into three groups based on the requirement for the use of combustible or noncombustible materials. What is the requirement for the noncombustible group?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
52
The International Building Code classifies types of construction into three groups based on the requirement for the use of combustible or noncombustible materials. What is the requirement for the noncombustible/combustible group?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
53
The International Building Code classifies types of construction into three groups based on the requirement for the use of combustible or noncombustible materials. What is the requirement for the combustible group?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
54
In determining the fire rating of an assembly through laboratory testing, an important criterion to meet is that it should maintain its structural integrity for the duration of its fire rating. What other criterion/criteria should the assembly satisfy during that duration?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
55
Give one example where fire- retardant- treated (FRT)wood or FRT plywood is permitted by the codes as substitute for noncombustible materials.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
56
A fire creates heat and smoke in buildings. Although both-high temperature and smoke-are deadly, which of the two contributes more to human fatalities?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
57
The nine types of construction in the International Building Code are divided into three groups: (i)noncombustible group, (ii)combustible group, and (iii)noncombustible/combustible group. Name the types of construction in noncombustible/combustible group.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
58
Name the quantity that measures the fire endurance of an assembly and give its units.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
59
Is fire endurance a material property or an assembly property?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
60
Is the fire rating of an assembly determined through calculations or laboratory testing?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
61
Using a sketch and notes, explain how the fire- resistance rating of an assembly is determined using ASTM standard E119.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
62
What does the acronym NFPA stand for?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
63
List the three groups into which the types of construction of buildings are divided based on whether the materials used in assemblies are combustible or noncombustible.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
64
The International Building Code classifies interior finishes as Class A, Class B, and Class C. Which material property(ies)are these classes based on?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
65
List two materials commonly used to increase the fire rating of an assembly.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
66
List the factors that affect fire safety in buildings.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
67
Describe the differences between Class A, Class B, and Class C interior finishes based on FSI and SDI.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
68
The required minimum fire ratings of various assemblies in Type III(A)and Type IV are essentially the same. What is the difference between these two types of construction?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
69
What is the type of construction of the building of Problem 8 if the floor's fire rating is 2 h, while all else remain unchanged?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
70
What does smoke developed index (SDI)mean? Does SDI apply to a material or an assembly?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
71
Explain why we need a test standard to determine whether a building material is combustible or noncombustible when we generally know which material is combustible and which is noncombustible.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
72
List the building assemblies that determine the type of construction classification of a building.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
73
The exterior walls of a building may pose a fire hazard to the adjacent building within the same lot or across the property line. Therefore, an exterior wall's minimum required fire rating is a function of its distance from the adjacent building, defined as fire separation distance (FSD)by the International Building Code. What is the required minimum value of FSD for a non- load- bearing wall (such as a glass curtain wall)so that the wall's fire rating may be zero?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
74
What is the difference between Type III(A)and Type IV construction? Explain.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
75
What does flame spread index (FSI)mean? Does FSI apply to a material or an assembly?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
76
Which type of construction is commonly used for single- family dwellings in the U.S.?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
77
Using a sketch and notes, explain what a fire wall is.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
78
Discuss the differences between a fire code and a building code.
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
79
What is a fire wall?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
80
Which is more fire safe-FSI = 10, or FSI = 50?
Unlock Deck
Unlock for access to all 84 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 84 flashcards in this deck.