Deck 16: Special Procedures
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/24
Play
Full screen (f)
Deck 16: Special Procedures
1
EPID can: I.use MV and kV
II)take orthogonal images
III)send images to multiple locations
A) I and II
B) II and III
C) I and III
D) I,II,and III
II)take orthogonal images
III)send images to multiple locations
A) I and II
B) II and III
C) I and III
D) I,II,and III
B
EPID uses only MV to create beam's-eye view images.
EPID uses only MV to create beam's-eye view images.
2
Heavy charged particles like protons have a(n)_____________ in tissue that is desirable.
A) continuous fall-off
B) sharp fall-off
C) shortened fall-off
D) absent fall-off
A) continuous fall-off
B) sharp fall-off
C) shortened fall-off
D) absent fall-off
B
An advantage of proton treatment is the Bragg Peak and the sharp fall-off.
An advantage of proton treatment is the Bragg Peak and the sharp fall-off.
3
Turning the radiation on and off when the target is within the treatment volume represents:
A) a fiducial system
B) gated treatments
C) a 4DCT data set
D) forced shallow breathing
A) a fiducial system
B) gated treatments
C) a 4DCT data set
D) forced shallow breathing
B
Gated treatments are performed when the radiation is turned on when the target is in the treatment volume and turned off when the target is outside the treatment volume.
Gated treatments are performed when the radiation is turned on when the target is in the treatment volume and turned off when the target is outside the treatment volume.
4
Forced shallow breathing technique is used to control:
A) compression
B) imaging
C) motion
D) interfraction dose
A) compression
B) imaging
C) motion
D) interfraction dose
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
5
A single fraction of radiation to a brain metastasis would be what kind of stereotactic treatment?
A) stereotactic radiation therapy (SRT)
B) stereotactic body radiation therapy (SBRT)
C) stereotactic radiosurgery (SRS)
A) stereotactic radiation therapy (SRT)
B) stereotactic body radiation therapy (SBRT)
C) stereotactic radiosurgery (SRS)
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
6
The kV images are preferred by radiation therapists and radiation oncologists because the:
A) contrast is better
B) metal artifacts are reduced
C) timing is more efficient
D) resolution is not an issue
A) contrast is better
B) metal artifacts are reduced
C) timing is more efficient
D) resolution is not an issue
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
7
The motion management method that defines an internal target volume is:
A) OBI
B) compression
C) conservative
D) MIP
A) OBI
B) compression
C) conservative
D) MIP
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
8
Besides the patient and reference frame being registered,the stereotactic treatment must also:
A) control motion
B) conform to the fiducial
C) increase target volume
D) reduce treatment time
A) control motion
B) conform to the fiducial
C) increase target volume
D) reduce treatment time
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
9
Cranial stereotactic treatments began with the:
A) CyberKnife
B) proton accelerator
C) Gamma Knife
D) SBRT
A) CyberKnife
B) proton accelerator
C) Gamma Knife
D) SBRT
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
10
TomoTherapy differs from some other volumetric imaging techniques because it:
A) is both a CT and a linear accelerator
B) uses kV and MV imaging
C) delivers customized fields
D) uses the same source for imaging and treating
A) is both a CT and a linear accelerator
B) uses kV and MV imaging
C) delivers customized fields
D) uses the same source for imaging and treating
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
11
Radiation oncology goals include all of the following except:
A) reduce side effects
B) deliver accurate and precise treatments
C) increase toxic effects
D) all of the above
A) reduce side effects
B) deliver accurate and precise treatments
C) increase toxic effects
D) all of the above
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
12
Stereotactic treatments have been improved on linear accelerators because of advances in:
A) high-quality in-room imaging
B) tighter mechanical specifications
C) small field treatments
D) a and b only
A) high-quality in-room imaging
B) tighter mechanical specifications
C) small field treatments
D) a and b only
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
13
The CyberKnife can treat anywhere in the body because it uses a(n)___________ technique.
A) nonisocentric
B) repetitive
C) real-time
D) isocentric
A) nonisocentric
B) repetitive
C) real-time
D) isocentric
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
14
For the ultrasound unit to know where it is in reference to the linear accelerator,it must be ________________ with the treatment delivery unit.
A) localized
B) attenuated
C) B-moded
D) registered
A) localized
B) attenuated
C) B-moded
D) registered
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
15
Cone beam CT,TomoTherapy,and CT-on rails correct for:
A) interfraction motion
B) intrafaction motion
A) interfraction motion
B) intrafaction motion
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
16
Protons are:
A) highly imaged
B) heavy charged particles
C) extended range
D) electrons
A) highly imaged
B) heavy charged particles
C) extended range
D) electrons
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
17
Organs that can be affected by motion are the: I.lung
II)liver
III)pancreas
A) I and II
B) II and III
C) I and III
D) I,II,and III
II)liver
III)pancreas
A) I and II
B) II and III
C) I and III
D) I,II,and III
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
18
The only approach to managing motion that allows for real-time feedback is:
A) 4DCT
B) gated treatment
C) RPM system
D) electromagnetic transponder
A) 4DCT
B) gated treatment
C) RPM system
D) electromagnetic transponder
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
19
Devices that are on the linear accelerator for imaging include all of the following except:
A) OBI
B) EPID
C) CT-on-rails
D) CBCT
A) OBI
B) EPID
C) CT-on-rails
D) CBCT
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
20
Respiratory motion can be managed by: I.rapid CT scanning
II)4DCT
III)two-breath-hold CT
A) I and II
B) II and III
C) I and III
D) I,II,and III
II)4DCT
III)two-breath-hold CT
A) I and II
B) II and III
C) I and III
D) I,II,and III
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
21
IGRT is useful because it can: I.result in a more focused treatment
II)account for interfraction and intrafraction motion
III)compare in-room image set with treatment planning image set
A) I and II
B) II and III
C) I and III
D) I,II,and III
II)account for interfraction and intrafraction motion
III)compare in-room image set with treatment planning image set
A) I and II
B) II and III
C) I and III
D) I,II,and III
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
22
A process that aligns multiple data sets into a single coordinate system so that the spatial locations of corresponding points coincide is:
A) registration
B) recombination
C) IGRT
D) MIP
A) registration
B) recombination
C) IGRT
D) MIP
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
23
Deformable image registration is easier than rigid body registration.
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
24
Cone beam CT:
A) uses a fan beam
B) has a 3D extended digital array
C) has an area detector with 2D extended digital array
D) has multiple rotational speeds
A) uses a fan beam
B) has a 3D extended digital array
C) has an area detector with 2D extended digital array
D) has multiple rotational speeds
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck