Deck 12: Chromatography

Full screen (f)
exit full mode
Question
A toxicology screen is set up using thin layer chromatographic plates.Four positive controls/standards are used with the following distance of migration from application point results: Std A = 8 cm; Std B = 15 cm; Std C = 22.The acetone solvent front moved 35 cm.After processing an unknown sample,a solute had a migration distance of 16 cm.What are the retention factors (Rf)of standards A,B,and C?

A) 8,15,22
B) 8,12,18
C) 4.4,2.3,1.5
D) 0.23,0.43,0.63
Use Space or
up arrow
down arrow
to flip the card.
Question
You are preparing placental tissue for separation and isolation of a specific enzyme.The enzyme has a negative charge,so you want to use chromatography to perform your task.Which one of the following chromatographic separation mechanisms would be most useful?

A) Ion-exchange
B) Partition
C) Affinity
D) Adsorption
Question
Which one of the following improvements could be made to increase the chromatographic (separation)efficiency of a poorly resolved HPLC separation?

A) Using a shorter column
B) Changing the composition of the mobile phase
C) Using smaller particles in the stationary phase
D) Increasing the dead volume
Question
In the thin layer chromatography procedure for drug screening,the retention factor (Rf)value for a compound is given by the:

A) ratio of distance moved by the unknown solute to distance moved by the solvent in the mobile phase.
B) rate of movement of the mobile phase through the adsorbent compared with standards and controls.
C) measurement in centimeters of the distance the solute moved in the mobile phase from the point of application.
D) distance moved by the mobile phase front from the point of application compared with a control.
Question
Thin layer chromatography is a type of planar chromatography with separation based on the principles of partition chromatography.
Question
In partition chromatography,separation is based on:

A) hydrogen bonding and hydrophobic interactions.
B) the molecular size of solutes in a solution and the size of the pores on the beads.
C) the ability of one component immobilized on a stationary phase to capture specific molecules in the mobile phase.
D) the differences in the relative solubility of compounds between the stationary and mobile phases.
Question
In the isolation of nucleic acids from blood samples,a step is typically performed to separate large molecules,such as proteins and nucleic acids,from smaller molecules such as salts.Which type of separation mechanism would best be suited for this task?

A) Ion exchange
B) Affinity
C) Partition
D) Size-exclusion
Question
Examine the following HPLC chromatograms,both of which were obtained from the same sample: A B
C:\Users\User\Dropbox\Quizplus Parsing Documents\To Be Parsed\Not Complete Tables\Chemistry\TB1858,Tietz Fundamentals of Clinical Chemistry and Molecular Diagnostics 7th Edition by Carl A.Burtis PhD\TB1858,Tietz Fundamentals of Clinical Chemistry and Molecular Diagnostics 7th Edition by Carl A.Burtis PhD\Images\C616(12)_2.jpg
Which chromatogram has the best resolution because of increased separation or chromatographic efficiency?

A) Chromatogram A
B) Chromatogram B
Question
A toxicology screen is set up using thin layer chromatographic plates.Four positive controls/standards are used with the following distance of migration from application point results: Std A = 8 cm; Std B = 15 cm; Std C = 22.The acetone solvent front moved 35 cm.After processing an unknown sample,a solute had a migration distance of 16 cm.What is the Rf of the unknown solute?

A) 0.23
B) 0.45
C) 1.94
D) 16
Question
A measure of peak separation in a chromatographic method that equals the difference in retention time for two components divided by the average of their peak widths is the definition of:

A) retention factor.
B) derivatization.
C) resolution.
D) affinity.
Question
The type of separation mechanism for chromatography that involves,as one example,use of immunologic principles is _____ chromatography.

A) ion exchange
B) affinity
C) partition
D) adsorption
Question
In HPLC,analyte detectors can consist of fluorometers,photometers,and electrochemical detectors.An electrochemical detector measures an electroactive analyte by:

A) monitoring the current that is generated by oxidation or reduction reaction under a constant potential voltage and that is proportional to the concentration of analyte.
B) measuring an electrical potential difference between two electrodes.
C) measuring the radiant energy given off when the chemical bonds of an element are dissociated and the element is placed in a ground or atomic state.
D) measuring both an alteration in enzyme level and a redox reaction at a potentiometric ion-specific electrode.
Question
In clinical applications using gas chromatography,which one of the following column temperature techniques will cause the more volatile analytes to elute first and therefore produce the best separation of complex mixtures of analytes with a range of volatilities?

A) Isothermal operation
B) Refrigerator (4° to 8° C)temperature operation
C) Temperature programmed operation
D) Room temperature operation
Question
In column chromatography,analytes are identified by their retention times.
Question
Some analytes must be derivatized to increase their column retention or detectability.Derivatization means:

A) altering the chemical structure of the analyte to an isomeric form to increase detection and specificity.
B) adding fluorescent labels or combining the analyte with chiral reagents or other chemicals to increase detectability.
C) removing dissolved gases in the solvent to produce a clear chromatogram.
D) using multiple detectors to assist in identification.
Question
What component of an HPLC introduces an aliquot of sample into the column and how is this introduction accomplished with the high pressure in the flow path?

A) A syringe is used with a flexible tip placed into the flow path.
B) A flame ionizes the sample and sprays it into the column.
C) A flexible septum is coated with sample and placed in the column.
D) A fixed-loop injector with a switching valve moves the sample into the flow path.
Question
A type of detector used in GC that is universal in its detection of compounds but has low sensitivity compared with other detectors is a(n)_____ detector.

A) flame ionization
B) thermal conductance
C) electron capture
D) photoionization
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/17
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 12: Chromatography
1
A toxicology screen is set up using thin layer chromatographic plates.Four positive controls/standards are used with the following distance of migration from application point results: Std A = 8 cm; Std B = 15 cm; Std C = 22.The acetone solvent front moved 35 cm.After processing an unknown sample,a solute had a migration distance of 16 cm.What are the retention factors (Rf)of standards A,B,and C?

A) 8,15,22
B) 8,12,18
C) 4.4,2.3,1.5
D) 0.23,0.43,0.63
0.23,0.43,0.63
2
You are preparing placental tissue for separation and isolation of a specific enzyme.The enzyme has a negative charge,so you want to use chromatography to perform your task.Which one of the following chromatographic separation mechanisms would be most useful?

A) Ion-exchange
B) Partition
C) Affinity
D) Adsorption
Ion-exchange
3
Which one of the following improvements could be made to increase the chromatographic (separation)efficiency of a poorly resolved HPLC separation?

A) Using a shorter column
B) Changing the composition of the mobile phase
C) Using smaller particles in the stationary phase
D) Increasing the dead volume
Using smaller particles in the stationary phase
4
In the thin layer chromatography procedure for drug screening,the retention factor (Rf)value for a compound is given by the:

A) ratio of distance moved by the unknown solute to distance moved by the solvent in the mobile phase.
B) rate of movement of the mobile phase through the adsorbent compared with standards and controls.
C) measurement in centimeters of the distance the solute moved in the mobile phase from the point of application.
D) distance moved by the mobile phase front from the point of application compared with a control.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
5
Thin layer chromatography is a type of planar chromatography with separation based on the principles of partition chromatography.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
6
In partition chromatography,separation is based on:

A) hydrogen bonding and hydrophobic interactions.
B) the molecular size of solutes in a solution and the size of the pores on the beads.
C) the ability of one component immobilized on a stationary phase to capture specific molecules in the mobile phase.
D) the differences in the relative solubility of compounds between the stationary and mobile phases.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
7
In the isolation of nucleic acids from blood samples,a step is typically performed to separate large molecules,such as proteins and nucleic acids,from smaller molecules such as salts.Which type of separation mechanism would best be suited for this task?

A) Ion exchange
B) Affinity
C) Partition
D) Size-exclusion
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
8
Examine the following HPLC chromatograms,both of which were obtained from the same sample: A B
C:\Users\User\Dropbox\Quizplus Parsing Documents\To Be Parsed\Not Complete Tables\Chemistry\TB1858,Tietz Fundamentals of Clinical Chemistry and Molecular Diagnostics 7th Edition by Carl A.Burtis PhD\TB1858,Tietz Fundamentals of Clinical Chemistry and Molecular Diagnostics 7th Edition by Carl A.Burtis PhD\Images\C616(12)_2.jpg
Which chromatogram has the best resolution because of increased separation or chromatographic efficiency?

A) Chromatogram A
B) Chromatogram B
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
9
A toxicology screen is set up using thin layer chromatographic plates.Four positive controls/standards are used with the following distance of migration from application point results: Std A = 8 cm; Std B = 15 cm; Std C = 22.The acetone solvent front moved 35 cm.After processing an unknown sample,a solute had a migration distance of 16 cm.What is the Rf of the unknown solute?

A) 0.23
B) 0.45
C) 1.94
D) 16
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
10
A measure of peak separation in a chromatographic method that equals the difference in retention time for two components divided by the average of their peak widths is the definition of:

A) retention factor.
B) derivatization.
C) resolution.
D) affinity.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
11
The type of separation mechanism for chromatography that involves,as one example,use of immunologic principles is _____ chromatography.

A) ion exchange
B) affinity
C) partition
D) adsorption
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
12
In HPLC,analyte detectors can consist of fluorometers,photometers,and electrochemical detectors.An electrochemical detector measures an electroactive analyte by:

A) monitoring the current that is generated by oxidation or reduction reaction under a constant potential voltage and that is proportional to the concentration of analyte.
B) measuring an electrical potential difference between two electrodes.
C) measuring the radiant energy given off when the chemical bonds of an element are dissociated and the element is placed in a ground or atomic state.
D) measuring both an alteration in enzyme level and a redox reaction at a potentiometric ion-specific electrode.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
13
In clinical applications using gas chromatography,which one of the following column temperature techniques will cause the more volatile analytes to elute first and therefore produce the best separation of complex mixtures of analytes with a range of volatilities?

A) Isothermal operation
B) Refrigerator (4° to 8° C)temperature operation
C) Temperature programmed operation
D) Room temperature operation
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
14
In column chromatography,analytes are identified by their retention times.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
15
Some analytes must be derivatized to increase their column retention or detectability.Derivatization means:

A) altering the chemical structure of the analyte to an isomeric form to increase detection and specificity.
B) adding fluorescent labels or combining the analyte with chiral reagents or other chemicals to increase detectability.
C) removing dissolved gases in the solvent to produce a clear chromatogram.
D) using multiple detectors to assist in identification.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
16
What component of an HPLC introduces an aliquot of sample into the column and how is this introduction accomplished with the high pressure in the flow path?

A) A syringe is used with a flexible tip placed into the flow path.
B) A flame ionizes the sample and sprays it into the column.
C) A flexible septum is coated with sample and placed in the column.
D) A fixed-loop injector with a switching valve moves the sample into the flow path.
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
17
A type of detector used in GC that is universal in its detection of compounds but has low sensitivity compared with other detectors is a(n)_____ detector.

A) flame ionization
B) thermal conductance
C) electron capture
D) photoionization
Unlock Deck
Unlock for access to all 17 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 17 flashcards in this deck.