Deck 3: The Dental X-Ray Machine: Components and Function
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/49
Play
Full screen (f)
Deck 3: The Dental X-Ray Machine: Components and Function
1
Electricity is defined as electrons in motion.
True
2
Which of the following removes the soft x-rays for the x-ray beam as it exits the port?
A) The positioning indicating device (PID)
B) The collimator
C) The filter
D) The transformer
A) The positioning indicating device (PID)
B) The collimator
C) The filter
D) The transformer
The filter
3
The anode is composed of the focusing cup and the filament, and must be charged negative during x-ray production.
A) The first part of the statement is correct, the second part of the statement is NOT correct.
B) The first part of the statement is NOT correct, the second part of the statement is correct.
C) Both parts of the statement are correct.
D) Both parts of the statement are NOT correct.
A) The first part of the statement is correct, the second part of the statement is NOT correct.
B) The first part of the statement is NOT correct, the second part of the statement is correct.
C) Both parts of the statement are correct.
D) Both parts of the statement are NOT correct.
Both parts of the statement are NOT correct.
4
Dental x-ray machines contain each of the following components EXCEPT one. Which one is the EXCEPTION?
A) Control panel
B) Extension arm
C) Radioactive material
D) Tube head
A) Control panel
B) Extension arm
C) Radioactive material
D) Tube head
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
5
How many electrical circuits are used in a dental x-ray machine?
A) One
B) Two
C) Three
D) Four
A) One
B) Two
C) Three
D) Four
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following best describes how x-rays are actually produced in the dental x-ray tube?
A) Radioactive particulate matter undergoes controlled disintegration.
B) Electrical current passes through an oil mixture, creating minute explosions.
C) Low milliamperage current is transformed to high kilovoltage current.
D) High-speed electrons collide with target material electrons.
A) Radioactive particulate matter undergoes controlled disintegration.
B) Electrical current passes through an oil mixture, creating minute explosions.
C) Low milliamperage current is transformed to high kilovoltage current.
D) High-speed electrons collide with target material electrons.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
7
The duration of an x-ray exposure is determined by which control?
A) The timer
B) The line switch
C) The kVp selector
D) The mA selector
A) The timer
B) The line switch
C) The kVp selector
D) The mA selector
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
8
What percent of the kinetic energy inside the x-ray tube is actually converted to x-radiation?
A) 99 percent
B) 50 percent
C) 25 percent
D) 1 percent
A) 99 percent
B) 50 percent
C) 25 percent
D) 1 percent
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
9
X-rays originate at the:
A) cathode.
B) port.
C) focusing cup.
D) focal spot.
A) cathode.
B) port.
C) focusing cup.
D) focal spot.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
10
Each of the following conditions must exist for x-rays to be produced EXCEPT one. Which one is the EXCEPTION?
A) A target capable of stopping the electrons
B) An air-filled glass tube
C) High voltage to impart speed to the electrons
D) A source of free electrons
A) A target capable of stopping the electrons
B) An air-filled glass tube
C) High voltage to impart speed to the electrons
D) A source of free electrons
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
11
Which of the following is NOT a function of the tube head?
A) It allows all radiation to exit.
B) It provides grounding for the electrical components.
C) It protects the x-ray tube from accidental damage.
D) It prevents overheating of the x-ray tube.
A) It allows all radiation to exit.
B) It provides grounding for the electrical components.
C) It protects the x-ray tube from accidental damage.
D) It prevents overheating of the x-ray tube.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
12
Amperage measures the electric potential or force that moves electrons along a conductor. Increasing the force with which the electrons move increases the penetrating potential of the x-ray beam.
A) The first statement is true. The second statement is false.
B) The first statement is false. The second statement is true.
C) Both statements are true.
D) Both statements are false.
A) The first statement is true. The second statement is false.
B) The first statement is false. The second statement is true.
C) Both statements are true.
D) Both statements are false.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
13
Which transformer corrects minor fluctuations in the current flowing through the wires?
A) The step-up transformer
B) The step-down transformer
C) The autotransformer
A) The step-up transformer
B) The step-down transformer
C) The autotransformer
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
14
Which of these statements is FALSE?
A) The positive anode and negative cathode are sealed within the x-ray tube.
B) The control panel may be integrated with the x-ray machine tube head support.
C) The exposure button should be on the end of a 3-foot timer cord.
D) The x-ray tube contains a target capable of stopping the electrons.
A) The positive anode and negative cathode are sealed within the x-ray tube.
B) The control panel may be integrated with the x-ray machine tube head support.
C) The exposure button should be on the end of a 3-foot timer cord.
D) The x-ray tube contains a target capable of stopping the electrons.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
15
The filament and target are made out of tungsten because it:
A) produces fewer electrons.
B) prevents electrons from being liberated.
C) withstands high temperatures.
D) ensures that x-rays are projected in one direction.
A) produces fewer electrons.
B) prevents electrons from being liberated.
C) withstands high temperatures.
D) ensures that x-rays are projected in one direction.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
16
Increasing which of the following would best increase the number of electrons flowing through the dental x-ray electrical circuit?
A) Impulses
B) Kilovoltage
C) Milliamperage
D) PID length
A) Impulses
B) Kilovoltage
C) Milliamperage
D) PID length
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
17
A 1/10-second exposure equals how many impulses?
A) 4
B) 6
C) 10
D) 60
A) 4
B) 6
C) 10
D) 60
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
18
Sixty (60) impulses is equivalent to:
A) 1/6 second.
B) 1/10 second.
C) ½ second.
D) 1 second.
A) 1/6 second.
B) 1/10 second.
C) ½ second.
D) 1 second.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
19
The intensity of the x-ray beam is affected by each of the following EXCEPT one. Which one is the EXCEPTION?
A) Target size
B) Kilovoltage
C) Exposure time
D) Milliamperage
A) Target size
B) Kilovoltage
C) Exposure time
D) Milliamperage
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
20
Which regulating device on the control panel measures the amount of current passing through the wires of the circuit?
A) The timer
B) The line switch
C) The kVp selector
D) The mA selector
A) The timer
B) The line switch
C) The kVp selector
D) The mA selector
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
21
The collimator is a lead diaphragm that restricts the dimensions of the useful beam.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
22
The intensity of the beam refers to the quantity and quality of the x-rays.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
23
Increasing the amperage will result in a production of more x-rays.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
24
That part of the cathode designed to direct the free electrons toward the tungsten target of the anode is called the "focal spot."
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
25
The metal housing of the tube head increases the safety of the x-ray machine.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
26
The filament is on the negative side of the vacuum tube in the dental x-ray machine.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
27
The tungsten anode is embedded in a core of copper to conduct heat away to a radiator.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
28
Voltage is the measurement of the number of electrons moving through a wire conductor.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
29
What does adjusting the kilovolt peak (kVp) do?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
30
The anode is the negative electrode (terminal) in the x-ray tube.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
31
Thermionic emission refers to the release of electrons from the target material during the process of incandescence.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
32
If the tube head is properly sealed, the port is the only place through which x-rays can escape.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
33
Primary beam refers to a high-energy, short wavelength x-ray beam.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
34
Direct current flows in pulses and changes direction.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
35
The step-down transformer corrects fluctuations in the current flowing through the x-ray machine.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
36
The x-ray beam formed at the focal spot is monochromatic.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
37
A small area on the tungsten target of the anode toward which the electron beam is directed is called the "focal spot."
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
38
An x-ray beam composed of many different wavelengths is called "polychromatic."
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
39
Dental x-ray machines may have controls for manual adjustment of kVp and mA, or these controls may be preset by the manufacturer.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
40
In the ON position, the line switch on the control panel energizes the low- and high-voltage circuits.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
41
Inside the dental x-ray machine, what does the speed of the electrons determine?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
42
Why are the extension arm and yoke of the x-ray machine insulated?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
43
What is the name of the device that allows the amount of current passing through the wires of the circuit to be changed?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
44
What is the term for the measurement of the number of electrons moving through a wire conductor?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
45
What is the purpose of a "deadman" exposure switch?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
46
What does kVp measure?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
47
In the cathode, the wire filament is recessed into what?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
48
What is the term for the process by which electrons are created at the filament wire of the cathode?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
49
Who is responsible for the radiation dose incurred by the patient during x-ray exposure?
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck