Exercise 100
In a balanced three-phase system, the abc-phase-sequence source is wye-connected and V an = 120 20° V rms. The load consists of two balanced wyes with phase impedances of 8 + j 2 and 12 + j 3 . If the line impedance is zero, find the line currents and the phase current in each load.
Explanation
Verified
like image
like image

The phase voltage is,
blured image .
The per-phase...