Deck 8: Instrument Processing

Full screen (f)
exit full mode
Question
Ultrasonic cleaner solution must be discarded:

A) every other day
B) once a week
C) at least once a day
D) once every 28 days
Use Space or
up arrow
down arrow
to flip the card.
Question
The ________ solution is an enzymatic solution that partially dissolves organic debris.
Question
When loading an autoclave sterilizer, larger packs are placed:

A) tilted at an angle
B) at the top of the chamber
C) at the bottom of the chamber
D) perpendicular to the floor
Question
Instruments rest in a holding solution in which step of instrument processing?

A) Transport
B) Cleaning
C) Packaging
D) Sterilization
Question
The ultrasonic cleaner is checked to see whether it is working properly by holding a 5-inch by 5-inch sheet of ____________ in the solution for 20 seconds.
Question
Process indicators that change color are useful for:

A) monitoring sterilization
B) identifying instrument packs that have been exposed to a certain temperature
C) determining whether an instrument package has been processed
D) both identifying instrument packs that have been exposed to a certain temperature and determining whether an instrument package has been processed
Question
Which parameter does NOT apply to both autoclave and chemical vapor sterilization?

A) Instruments must be absolutely dry.
B) Articles and packs must be separated from each other.
C) Pressure and temperature must be reached before timing begins.
D) Process integrators must be inserted into the test load instrument package.
Question
Why are instruments wrapped or packaged before sterilization?

A) To keep them from rusting
B) To disinfect the instruments
C) To protect them from becoming contaminated after sterilization
D) To provide a simple system of instrument organization
Question
Packaging materials and cassettes for sterilization must be approved by the:

A) Environmental Protection Agency (EPA)
B) Occupational Safety and Health Administration (OSHA)
C) state dental board
D) Food and Drug Administration (FDA)
Question
A dry heat sterilizer is inadvertently opened mid-cycle, but quickly shut again to finish the cycle, with no other adjustment. Which sterilization error has occurred?

A) Improper loading
B) Improper timing
C) Inadequate instrument cleaning
D) Improper packaging
Question
All soiled instruments are brought into the ________ area.
Question
An ideal instrument processing area:

A) is located in a separate building from the dental practice
B) contains a dental laboratory and sterilization center
C) is part of a common walkway
D) is uncarpeted with multiple outlets and a vacuum line
Question
Standard packaging for chemical vapor sterilization includes all of the following EXCEPT:

A) film pouches or paper bags
B) solid metal trays
C) sterilization wrap
D) nylon see-through tubing
Question
The ultrasonic cleaner works by producing ________.
Question
Which is the LEAST desirable method of cleaning instruments?

A) Ultrasonic cleaning
B) Hand scrubbing
C) Automated instrument washers
D) Thermal disinfectors
Question
The only approved way to determine that sterilization has actually occurred is to use:

A) process integrators
B) biologic monitors
C) process indicators
D) multiparameter indicators
Question
Which method of sterilization is best for plastic shade guides and rubber dam frames?

A) Autoclave
B) Chemical vapor
C) Dry heat
D) Chemical liquid
Question
Liquid chemical sterilant must be covered, because glutaraldehyde produces toxic fumes.

A) The statement is correct, but the reason is not.
B) The statement is not correct, but the reason is correct.
C) Both the statement and the reason are correct and related.
D) Both the statement and the reason are correct but not related.
Question
The workflow pattern for instrument processing should proceed in a single loop from:

A) dirty, to sterile, to storage
B) dirty, to clean, to sterile, to storage
C) dirty, to preclean, to clean, to storage
D) dirty, to preclean, to clean, to sterilize, to storage
Question
Examples of process integrators include all of the following EXCEPT:

A) aluminum foil
B) strips
C) tubes of colored liquid
D) tabs
Question
An additional advantage to packaging instruments is that they can be grouped into special setups.
Question
A _________ sterilizer is similar to an oven-hot air rises through natural convention.
Question
A _______ report from a biologic indicator indicates that sterilization did not occur.
Question
In a dry heat sterilizer, you must clean and dry instruments before wrapping them.
Question
There are many other ways to confirm if sterilization has occurred, aside from spore testing.
Question
If the spores are killed on a biologic indicator, it will be a _______culture, which means the sterilization cycle was successful.
Question
Process __________ are placed outside the instrument packages before sterilization.
Question
An _______ is used to sterilize dental instruments by means of steam under pressure.
Question
Aluminum foil, metal, and glass containers may all be used in a static air sterilizer.
Question
Sporox II is a _______-level disinfectant/sterilant used for instruments that cannot tolerate heat sterilization.
Question
The first step in instrument processing is to put on your utility gloves.
Question
Process integrators are placed inside instrument packages.
Question
Another name for spore testing is process indicating.
Question
An alternative to using rust inhibitors is drying instruments thoroughly using dry heat or chemical vapor.
Question
It is neither cost-effective nor desirable to use a disinfectant alone as a holding solution.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/35
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 8: Instrument Processing
1
Ultrasonic cleaner solution must be discarded:

A) every other day
B) once a week
C) at least once a day
D) once every 28 days
at least once a day
2
The ________ solution is an enzymatic solution that partially dissolves organic debris.
holding
3
When loading an autoclave sterilizer, larger packs are placed:

A) tilted at an angle
B) at the top of the chamber
C) at the bottom of the chamber
D) perpendicular to the floor
at the bottom of the chamber
4
Instruments rest in a holding solution in which step of instrument processing?

A) Transport
B) Cleaning
C) Packaging
D) Sterilization
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
5
The ultrasonic cleaner is checked to see whether it is working properly by holding a 5-inch by 5-inch sheet of ____________ in the solution for 20 seconds.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
6
Process indicators that change color are useful for:

A) monitoring sterilization
B) identifying instrument packs that have been exposed to a certain temperature
C) determining whether an instrument package has been processed
D) both identifying instrument packs that have been exposed to a certain temperature and determining whether an instrument package has been processed
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
7
Which parameter does NOT apply to both autoclave and chemical vapor sterilization?

A) Instruments must be absolutely dry.
B) Articles and packs must be separated from each other.
C) Pressure and temperature must be reached before timing begins.
D) Process integrators must be inserted into the test load instrument package.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
8
Why are instruments wrapped or packaged before sterilization?

A) To keep them from rusting
B) To disinfect the instruments
C) To protect them from becoming contaminated after sterilization
D) To provide a simple system of instrument organization
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
9
Packaging materials and cassettes for sterilization must be approved by the:

A) Environmental Protection Agency (EPA)
B) Occupational Safety and Health Administration (OSHA)
C) state dental board
D) Food and Drug Administration (FDA)
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
10
A dry heat sterilizer is inadvertently opened mid-cycle, but quickly shut again to finish the cycle, with no other adjustment. Which sterilization error has occurred?

A) Improper loading
B) Improper timing
C) Inadequate instrument cleaning
D) Improper packaging
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
11
All soiled instruments are brought into the ________ area.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
12
An ideal instrument processing area:

A) is located in a separate building from the dental practice
B) contains a dental laboratory and sterilization center
C) is part of a common walkway
D) is uncarpeted with multiple outlets and a vacuum line
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
13
Standard packaging for chemical vapor sterilization includes all of the following EXCEPT:

A) film pouches or paper bags
B) solid metal trays
C) sterilization wrap
D) nylon see-through tubing
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
14
The ultrasonic cleaner works by producing ________.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
15
Which is the LEAST desirable method of cleaning instruments?

A) Ultrasonic cleaning
B) Hand scrubbing
C) Automated instrument washers
D) Thermal disinfectors
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
16
The only approved way to determine that sterilization has actually occurred is to use:

A) process integrators
B) biologic monitors
C) process indicators
D) multiparameter indicators
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
17
Which method of sterilization is best for plastic shade guides and rubber dam frames?

A) Autoclave
B) Chemical vapor
C) Dry heat
D) Chemical liquid
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
18
Liquid chemical sterilant must be covered, because glutaraldehyde produces toxic fumes.

A) The statement is correct, but the reason is not.
B) The statement is not correct, but the reason is correct.
C) Both the statement and the reason are correct and related.
D) Both the statement and the reason are correct but not related.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
19
The workflow pattern for instrument processing should proceed in a single loop from:

A) dirty, to sterile, to storage
B) dirty, to clean, to sterile, to storage
C) dirty, to preclean, to clean, to storage
D) dirty, to preclean, to clean, to sterilize, to storage
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
20
Examples of process integrators include all of the following EXCEPT:

A) aluminum foil
B) strips
C) tubes of colored liquid
D) tabs
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
21
An additional advantage to packaging instruments is that they can be grouped into special setups.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
22
A _________ sterilizer is similar to an oven-hot air rises through natural convention.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
23
A _______ report from a biologic indicator indicates that sterilization did not occur.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
24
In a dry heat sterilizer, you must clean and dry instruments before wrapping them.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
25
There are many other ways to confirm if sterilization has occurred, aside from spore testing.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
26
If the spores are killed on a biologic indicator, it will be a _______culture, which means the sterilization cycle was successful.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
27
Process __________ are placed outside the instrument packages before sterilization.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
28
An _______ is used to sterilize dental instruments by means of steam under pressure.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
29
Aluminum foil, metal, and glass containers may all be used in a static air sterilizer.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
30
Sporox II is a _______-level disinfectant/sterilant used for instruments that cannot tolerate heat sterilization.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
31
The first step in instrument processing is to put on your utility gloves.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
32
Process integrators are placed inside instrument packages.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
33
Another name for spore testing is process indicating.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
34
An alternative to using rust inhibitors is drying instruments thoroughly using dry heat or chemical vapor.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
35
It is neither cost-effective nor desirable to use a disinfectant alone as a holding solution.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 35 flashcards in this deck.