Deck 13: Exposure Technique Selection
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/59
Play
Full screen (f)
Deck 13: Exposure Technique Selection
1
Phototimer AEC detectors are usually exit-type devices because
A) the x-rays must exit the patient to get to the detectors
B) the x-rays must exit the grid to get to the detectors
C) the x-rays must exit the image receptor to get to the detectors
D) the x-rays must exit the table to get to the detectors
A) the x-rays must exit the patient to get to the detectors
B) the x-rays must exit the grid to get to the detectors
C) the x-rays must exit the image receptor to get to the detectors
D) the x-rays must exit the table to get to the detectors
the x-rays must exit the image receptor to get to the detectors
2
When using AEC, the kVp
A) is set higher than usual
B) is set lower than usual
C) is set as appropriate for the study
D) is determined by the AEC system
A) is set higher than usual
B) is set lower than usual
C) is set as appropriate for the study
D) is determined by the AEC system
is set as appropriate for the study
3
The predetermined level of radiation exposure needed to terminate the exposure when using AEC is set by
A) the radiologist
B) the technologist
C) the equipment service personnel
D) the manufacturer
A) the radiologist
B) the technologist
C) the equipment service personnel
D) the manufacturer
the equipment service personnel
4
There is typically a configuration of at least ______ AEC detectors in place
A) 2
B) 3
C) 4
D) 5
A) 2
B) 3
C) 4
D) 5
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
5
An ionization chamber is a hollow cell that contains
A) water
B) lead
C) tungsten
D) air
A) water
B) lead
C) tungsten
D) air
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
6
Using a lower mA station during an AEC examination results in
A) reduced patient exposure
B) increased exposure time
C) decreased exposure time
D) reduced patient exposure and increased exposure time
A) reduced patient exposure
B) increased exposure time
C) decreased exposure time
D) reduced patient exposure and increased exposure time
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
7
The device that converts the light energy to an electrical signal is the
A) photodiode
B) photocathode
C) photomultiplier tube
D) photodiode and photomultiplier tube
A) photodiode
B) photocathode
C) photomultiplier tube
D) photodiode and photomultiplier tube
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
8
The shortest exposure time that a radiographic tube with AEC can have is the
A) mAs readout
B) back-up time
C) minimum response time
D) density controls
A) mAs readout
B) back-up time
C) minimum response time
D) density controls
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
9
AEC controls the amount of radiation reaching the IR by controlling the
A) time of exposure
B) mA
C) kVp
D) none of these
A) time of exposure
B) mA
C) kVp
D) none of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
10
The two types of detectors used in AEC are
A) image intensifiers and phototimers
B) phototimers and ionization chambers
C) ionization chambers and Geiger counters
D) direct and indirect capture
A) image intensifiers and phototimers
B) phototimers and ionization chambers
C) ionization chambers and Geiger counters
D) direct and indirect capture
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
11
These can be adjusted to increase or decrease the amount of radiation needed to terminate the exposure using AEC
A) mAs readout
B) back-up time
C) minimum response time
D) exposure adjustment
A) mAs readout
B) back-up time
C) minimum response time
D) exposure adjustment
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
12
The actual amount of exposure used for an image when AEC is being used is the
A) mAs readout
B) back-up time
C) minimum response time
D) density controls
A) mAs readout
B) back-up time
C) minimum response time
D) density controls
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
13
The maximum length of time that an exposure lasts when using AEC is the
A) mAs readout
B) back-up time
C) minimum response time
D) exposure adjustment
A) mAs readout
B) back-up time
C) minimum response time
D) exposure adjustment
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
14
Once the electric charge from an AEC detector reaches a preset point
A) the patient can leave
B) the kVp will be reduced to 0
C) the exposure will stop
D) All of these
A) the patient can leave
B) the kVp will be reduced to 0
C) the exposure will stop
D) All of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
15
The primary purpose of AEC is to
A) reduce patient exposure
B) control the amount of radiation reaching the IR
C) control image contrast
D) eliminate the need for the radiographer to think critically
A) reduce patient exposure
B) control the amount of radiation reaching the IR
C) control image contrast
D) eliminate the need for the radiographer to think critically
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
16
Using a higher kVp during an AEC examination results in
A) a longer exposure time
B) a shorter exposure time
C) increased patient exposure
D) a shorter exposure time and increased patient exposure
A) a longer exposure time
B) a shorter exposure time
C) increased patient exposure
D) a shorter exposure time and increased patient exposure
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
17
Today's AEC system is most likely use a(n)
A) ionization chamber
B) Geiger counter
C) phototimer
D) none of these
A) ionization chamber
B) Geiger counter
C) phototimer
D) none of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
18
The original type of AEC detector was the
A) ionization chamber
B) Geiger counter
C) phototimer
D) none of these
A) ionization chamber
B) Geiger counter
C) phototimer
D) none of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
19
When the x-rays enter the ionization chamber
A) atoms become ions
B) atoms give up electrons
C) electrons and positive ions become electricity
D) All of these
A) atoms become ions
B) atoms give up electrons
C) electrons and positive ions become electricity
D) All of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
20
Ionization chamber AEC detectors are entrance-type devices because the x-rays must
A) enter the detector after passing through the IR
B) enter the detector before entering the patient
C) enter the detector before getting to the IR
A) enter the detector after passing through the IR
B) enter the detector before entering the patient
C) enter the detector before getting to the IR
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
21
When the radiographer has the opportunity to set the back-up time, it should be approximately _____________ of the expected exposure time
A) 50%
B) 150%
C) 250%
D) 600%
A) 50%
B) 150%
C) 250%
D) 600%
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
22
If the radiographer is doing an upright chest using AEC but the table bucky is selected
A) the back-up time will be reached
B) the patient will be exposed to excessive radiation
C) the IR will be overexposed
D) All of these
A) the back-up time will be reached
B) the patient will be exposed to excessive radiation
C) the IR will be overexposed
D) All of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
23
If the back-up time is set by the equipment, the exposure time should end when the mAs reaches
A) 100
B) 400
C) 600
D) 1000
A) 100
B) 400
C) 600
D) 1000
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
24
If the patient for an AP thoracic spine image is centered so that the spine is not over the top of the detector
A) the IR exposure will be excessive
B) the IR exposure will be insufficient
C) the mAs will compensate
D) the image will be too light
A) the IR exposure will be excessive
B) the IR exposure will be insufficient
C) the mAs will compensate
D) the image will be too light
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
25
When your patient for an AP abdomen is very heavy, using AEC results in
A) underexposure to the IR
B) overexposure to the IR
C) appropriate exposure to the IR
D) increased image contrast
A) underexposure to the IR
B) overexposure to the IR
C) appropriate exposure to the IR
D) increased image contrast
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
26
When there is a significant amount of scatter radiation reaching the detector, the exposure time will
A) be shorter than needed
B) be appropriate
C) be longer than needed
D) reach the backup mAs
A) be shorter than needed
B) be appropriate
C) be longer than needed
D) reach the backup mAs
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
27
If the back-up time is shorter than the actual exposure time needed for a properly exposed image
A) the image receptor will be overexposed
B) the image receptor will be underexposed
C) the exposure will be appropriate
D) the x-ray tube will overheat
A) the image receptor will be overexposed
B) the image receptor will be underexposed
C) the exposure will be appropriate
D) the x-ray tube will overheat
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
28
In imaging a child, a short exposure time is needed for an examination using AEC. The mA setting should
A) be low
B) be mid-range
C) be high
D) It doesn't matter-the AEC device will control the exposure time
A) be low
B) be mid-range
C) be high
D) It doesn't matter-the AEC device will control the exposure time
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
29
With digital imaging using AEC, if an AP thoracic spine is imaged using an outside instead of center detector, the brightness in the area of interest will be _________________ and the patient will be underexposed. (Assume all other factors are appropriate.)
A) gray
B) light
C) dark
D) appropriate
A) gray
B) light
C) dark
D) appropriate
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
30
If the AEC detectors are not completely covered by the part being imaged and are exposed to primary radiation
A) the patient will be overexposed
B) the exposure will terminate very quickly
C) the IR will be exposed to the appropriate amount of radiation
D) none of these
A) the patient will be overexposed
B) the exposure will terminate very quickly
C) the IR will be exposed to the appropriate amount of radiation
D) none of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
31
When using AEC, destructive pathologic conditions can cause
A) overexposure
B) decreased absorption
C) excessive overexposure
D) increased absorption
A) overexposure
B) decreased absorption
C) excessive overexposure
D) increased absorption
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
32
When imaging a patient's right hip, which detector(s) should be activated?
A) right detector only
B) right and left detector
C) center detector only
D) all three detectors
A) right detector only
B) right and left detector
C) center detector only
D) all three detectors
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
33
Which of the following is the most critical aspect of successfully performing an examination using AEC?
A) Centering the anatomy of interest over the detector
B) Using the right mA
C) Using the right kVp
D) Setting the best back-up time
A) Centering the anatomy of interest over the detector
B) Using the right mA
C) Using the right kVp
D) Setting the best back-up time
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
34
AEC devices should be calibrated
A) when the unit is first installed
B) at regular intervals
C) when there is a change in the type of IR being used
D) All of these
A) when the unit is first installed
B) at regular intervals
C) when there is a change in the type of IR being used
D) All of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
35
The Quality control test of the AEC device to see that exposures for a given set of factors and selected detector result in mR readings within 5%, is known as:
A) reproducibility;
B) linearity
C) reciprocity
D) accuracy
A) reproducibility;
B) linearity
C) reciprocity
D) accuracy
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
36
When using AEC with digital imaging, errors resulting in overexposure to the IR result in
A) images that have insufficient brightness
B) images with appropriate brightness
C) overexposed patients
D) images with appropriate brightness and overexposed patients
A) images that have insufficient brightness
B) images with appropriate brightness
C) overexposed patients
D) images with appropriate brightness and overexposed patients
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
37
The AEC minimum response time may pose a problem when
A) a long exposure time is needed
B) the patient can easily hold still for the exposure
C) the patient is unable to hold still for the exposure
D) All of these
A) a long exposure time is needed
B) the patient can easily hold still for the exposure
C) the patient is unable to hold still for the exposure
D) All of these
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
38
Anatomically programmed technique is a system in which the radiographer selects
A) AEC settings
B) mAs and kVp settings
C) preset settings based on the part being imaged
D) preset settings based on the size of the patient
A) AEC settings
B) mAs and kVp settings
C) preset settings based on the part being imaged
D) preset settings based on the size of the patient
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
39
The reason to have a back-up time is to
A) protect the patient from excessive exposure
B) make sure the right mAs is used
C) keep the tube from excessive heat-loading
D) protect the patient from excessive exposure and keep the tube from excessive heat-loading
A) protect the patient from excessive exposure
B) make sure the right mAs is used
C) keep the tube from excessive heat-loading
D) protect the patient from excessive exposure and keep the tube from excessive heat-loading
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
40
The detector(s) selected for an image should be
A) the center detector because that is where the central ray is going
B) the two or three detectors that are covered by the part being imaged
C) the ones that are superimposed by the anatomic structure of interest
D) all three so that the system can work properly
A) the center detector because that is where the central ray is going
B) the two or three detectors that are covered by the part being imaged
C) the ones that are superimposed by the anatomic structure of interest
D) all three so that the system can work properly
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
41
The amount of electric charge produced in an AEC detector depends on the amount of radiation absorbed by the detector.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
42
Pre-established guidelines used by the radiographer to select standardized manual or AEC exposure factors for each type of radiographic examination are called
A) anatomical programming
B) exposure technique charts
C) mA reciprocity
D) quantum noise detectors
A) anatomical programming
B) exposure technique charts
C) mA reciprocity
D) quantum noise detectors
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
43
___________________ identify optimal kVp values and alter the mAs for variations in part thickness
A) Fixed kVp-variable mAs
B) Variable kVp-variable mAs
C) Fixed kVp-Fixed mAs
D) Variable kVp-fixed mAs
A) Fixed kVp-variable mAs
B) Variable kVp-variable mAs
C) Fixed kVp-Fixed mAs
D) Variable kVp-fixed mAs
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
44
Which of the following patient conditions require a change in technical factors?
1) Plaster casts
2) Obesity
3) Additive disease
A) plaster casts and obesity only
B) plaster casts and additive disease only
C) obesity and additive disease only
D) plaster casts, obesity, and additive disease
1) Plaster casts
2) Obesity
3) Additive disease
A) plaster casts and obesity only
B) plaster casts and additive disease only
C) obesity and additive disease only
D) plaster casts, obesity, and additive disease
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
45
Using the plus or minus exposure adjustments should be done frequently to produce quality images with AEC.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
46
When using AEC, the exit radiation is converted into an electrical signal.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
47
With digital imaging using AEC, what factor is decreased if an AP thoracic spine is imaged using an outside instead of the center detector? (Assume all other factors are appropriate.)
A) exposure time
B) increased; subject contrast
C) spatial resolution
D) brightness
A) exposure time
B) increased; subject contrast
C) spatial resolution
D) brightness
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
48
With digital imaging using AEC, if an AP thoracic spine is imaged using 110 kVp instead of 80 kVp, the patient exposure is _______________________. (Assume all other factors are appropriate.)
A) higher
B) unchanged
C) lower
D) excessive
A) higher
B) unchanged
C) lower
D) excessive
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
49
With digital imaging using AEC, what factor is increased if an AP thoracic spine is imaged using an outside instead of the center detector? (Assume all other factors are appropriate.)
A) subject contrast
B) brightness
C) spatial resolution
D) quantum noise
A) subject contrast
B) brightness
C) spatial resolution
D) quantum noise
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
50
Different radiographic projections and patient positions of the same anatomic part do not require modification of the exposure factors.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
51
If an AEC has three detectors, only one of the three can be selected for an exposure.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
52
Phototimer AEC devices convert the radiation to light energy.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
53
It is safe to assume that anatomically programmed techniques have been developed to produce the best quality images with the least amount of exposure.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
54
The AEC system will automatically adjust to changing image receptor types.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
55
The mAs readout is of little value because there is no need to set manual exposure factors.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
56
With digital imaging using AEC, if an AP thoracic spine is imaged with the central ray passing 3 inches to the right of the spine, the right lung exposure is _________________. (Assume all other factors are appropriate.)
A) excessive
B) insufficient
C) sufficient
D) too long
A) excessive
B) insufficient
C) sufficient
D) too long
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
57
With digital imaging using AEC, if an AP thoracic spine is imaged with the exposure adjustment changed from 0 to +2, the exposure time is _______________________. (Assume all other factors are appropriate.)
A) longer
B) shorter
C) unchanged
D) insufficient
A) longer
B) shorter
C) unchanged
D) insufficient
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
58
Collimation is not required when AEC is used.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck
59
AEC and phototiming are accurate terms that can be used in place of automatic exposure control.
Unlock Deck
Unlock for access to all 59 flashcards in this deck.
Unlock Deck
k this deck