Deck 8: Load Calculations
1
Multiplying voltage by amperage produces ____.
A) kilo-volts (kV)
B) kilo-watts (kW)
C) kilo-amperes (kA)
D) volt-amperes (VA)
A) kilo-volts (kV)
B) kilo-watts (kW)
C) kilo-amperes (kA)
D) volt-amperes (VA)
D
2
The lighting load for residential dwelling units is ____ volt-amperes (VA) per square foot.
A) 3
B) 6
C) 9
D) 12
A) 3
B) 6
C) 9
D) 12
A
3
The ____, including the strip heat and blower motor, is necessary information for calculating loads.
A) heat sink percentage
B) total wattage in kilo-watts
C) total volt-ampere load
D) British Thermal Units (BTUs)
A) heat sink percentage
B) total wattage in kilo-watts
C) total volt-ampere load
D) British Thermal Units (BTUs)
C
4
A scale ruler is used in ____.
A) determining the number of outlets
B) determining outlet ampacity
C) determining the location of outlets
D) converting units
A) determining the number of outlets
B) determining outlet ampacity
C) determining the location of outlets
D) converting units
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
A clothes dryer neutral load on a feeder can be calculated at ____%.
A) 20
B) 50
C) 70
D) 75
A) 20
B) 50
C) 70
D) 75
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Horsepower ratings must be converted to ____ before they can be added to the load calculation form.
A) kilo-volts (kV)
B) kilo-watts (kW)
C) volt-amperes (VA)
D) kilo-amperes (kA)
A) kilo-volts (kV)
B) kilo-watts (kW)
C) volt-amperes (VA)
D) kilo-amperes (kA)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
A dwelling unit must have at least ____ small-appliance branch circuit(s).
A) one
B) two
C) three
D) four
A) one
B) two
C) three
D) four
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
The smaller of two (or more) ____ loads can be omitted, as long as they are never energized simultaneously.
A) noncoincident
B) nonsingular
C) incidental
D) compressor
A) noncoincident
B) nonsingular
C) incidental
D) compressor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
The term ____ designates utilization equipment commonly built in standardized types and sizes and installed as a unit to perform specific function(s).
A) receptacle
B) feeder
C) appliance
D) neutral conductor
A) receptacle
B) feeder
C) appliance
D) neutral conductor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
For the purpose of the standard method load calculation for a one-family dwelling, the terms neutral and ____ are synonymous.
A) load balanced
B) grounded
C) nonpositive
D) charged
A) load balanced
B) grounded
C) nonpositive
D) charged
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
The ____ is not an important piece of information to gather before performing load calculations.
A) dwelling's total square-foot (ft2) area
B) number of laundry circuits that will be installed
C) fastened-in-place appliances that will be installed
D) location of circuit breakers
A) dwelling's total square-foot (ft2) area
B) number of laundry circuits that will be installed
C) fastened-in-place appliances that will be installed
D) location of circuit breakers
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Individual household cooking appliances rated more than ____ watts (volt-amperes) can be derated by using Table 220.55 demand factors (and all of the applicable notes).
A) 1000
B) 1250
C) 1500
D) 1750
A) 1000
B) 1250
C) 1500
D) 1750
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Load calculations must be performed in order to determine the ____.
A) size of circuit breakers
B) size of services and feeders
C) voltage drop across all circuits
D) placement of fuse boxes
A) size of circuit breakers
B) size of services and feeders
C) voltage drop across all circuits
D) placement of fuse boxes
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
____ are not included in the calculated floor area of dwelling units.
A) Kitchen spaces
B) Laundry/utility rooms
C) Open porches
D) Roofed overhangs
A) Kitchen spaces
B) Laundry/utility rooms
C) Open porches
D) Roofed overhangs
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
A feeder is defined as all circuit conductors between the ____ containing fuses or breakers that feed branch circuits.
A) main power source and the junction box
B) service disconnecting means and the panelboard
C) main power source and the fuse box
D) auxiliary service line and the panelboard
A) main power source and the junction box
B) service disconnecting means and the panelboard
C) main power source and the fuse box
D) auxiliary service line and the panelboard
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
No derating is allowed when there are only one, two, or three ____ appliances.
A) kitchen
B) laundry
C) fastened-in-place
D) small
A) kitchen
B) laundry
C) fastened-in-place
D) small
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
A demand factor of ____% can be applied to the nameplate rating load of four or more fastened-in-place appliances.
A) 35
B) 50
C) 65
D) 75
A) 35
B) 50
C) 65
D) 75
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
Each laundry branch circuit is calculated at _____.
A) no more than 1500 volt-amperes
B) no less than 1500 volt-amperes
C) no more than 1000 volt-amperes
D) no less than 1000 volt-amperes
A) no more than 1500 volt-amperes
B) no less than 1500 volt-amperes
C) no more than 1000 volt-amperes
D) no less than 1000 volt-amperes
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
____ must be included when calculating a dwelling unit service.
A) Detached garage space loads
B) Crawl space branch circuits
C) Refrigeration equipment loads
D) Small-appliance branch circuits
A) Detached garage space loads
B) Crawl space branch circuits
C) Refrigeration equipment loads
D) Small-appliance branch circuits
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
The ____ for each floor of a one-family dwelling shall be computed using the outside dimensions.
A) lighting load
B) residential space
C) load capacity
D) floor area
A) lighting load
B) residential space
C) load capacity
D) floor area
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
The exact nameplate rating of the clothes dryer, even if less than ____ volt-amperes should be used in load calculations.
A) 1000
B) 2500
C) 5000
D) 7000
A) 1000
B) 2500
C) 5000
D) 7000
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
____ are not included in calculating receptacle loads for appliances.
A) Air-conditioning systems
B) Counter-mounted cooking units
C) Clothes dryers
D) Wall-mounted ovens
A) Air-conditioning systems
B) Counter-mounted cooking units
C) Clothes dryers
D) Wall-mounted ovens
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
The minimum size grounding electrode conductor is ____ AWG copper (or 4 AWG aluminum).
A) 2
B) 4
C) 6
D) 8
A) 2
B) 4
C) 6
D) 8
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
For a service rated 100 through 400 A, the service conductors supplying the entire load associated with a one-family dwelling shall be permitted to have an ampacity not less than _____% of the service rating.
A) 68
B) 83
C) 100
D) 112
A) 68
B) 83
C) 100
D) 112
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
In outdoor applications, ____ grounding electrode conductors must not be installed within 18 in.(450 mm) of the earth.
A) stainless steel
B) copper
C) aluminum
D) composite
A) stainless steel
B) copper
C) aluminum
D) composite
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck