Deck 23: Inlet-Metering Rotary Distributor Pumps

Full screen (f)
exit full mode
Question
Technician A says that most hydromechanical rotary-distributor diesel injection pumps are used in indirect injection (IDI) applications. Technician B says that most hydromechanical rotary-distributor diesel injection pumps are used to fuel off-highway large bore engines. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Use Space or
up arrow
down arrow
to flip the card.
Question
What is the function of the delivery valve used on an inlet metering, opposed plunger, type of rotary distributor pump?

A) raises the nozzle opening pressure
B) retains residual line pressure
C) limits peak line pressure
D) prevents high pressure spikes
Question
What is used to lubricate the internal components of an inlet metering, opposed plunger, rotary injection pump during operation?

A) integral supply of engine oil
B) external supply of engine oil
C) sealed bearings
D) fuel from the vane pump
Question
At what relative speed must an inlet metering, opposed plunger injection pump be driven when used to fuel a 4-stroke cycle diesel engine, with 6 engine cylinders?

A) half engine speed
B) engine speed
C) two times engine speed
D) six times engine speed
Question
How many high pressure pumping chambers are used in a typical inlet metering, opposed plunger rotary distributor injection pump?

A) one
B) two
C) four
D) six
Question
How many pumping plungers are used in the high pressure pump element used in an inlet metering, opposed plunger, rotary distributor pump used to fuel a six cylinder engine?

A) six
B) four
C) two
D) one
Question
Technician A says that an inlet metering, opposed plunger rotary distributor pump cannot be used to fuel an engine with more than six cylinders. Technician B says that a Stanadyne opposed plunger, rotary distributor pumps used to be popular on older Ford and GM diesel engines. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
An inlet metering, opposed plunger rotary distributor pump is used to fuel an automotive V-8 diesel engine. How many delivery valves are used?

A) one
B) two
C) four
D) eight
Question
Technician A says that the outward movement of the opposed plungers in an inlet metering, rotary distributor pump depends on centrifugal force and therefore, pump rotational speed. Technician B says that plunger outboard travel on the same pump is limited by leaf spring stops. Who is right?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
What force is used to move the advance piston in an inlet metering, opposed plunger rotary distributor pump that uses no computer controls?

A) spring force
B) centrifugal force
C) hydraulic force
D) mechanical force
Question
Which component(s) in an inlet metering, opposed plunger rotary distributor pump is moved by the advance piston?

A) opposed plungers
B) hydraulic head
C) metering valve
D) internal cam ring
Question
Which of the following best describes the operating principle of the vane type transfer pumps used on typical inlet metering, opposed plunger, rotary distributor pump?

A) centrifugal
B) constant velocity
C) variable cycle
D) positive displacement
Question
Which of the following would have the effect of advancing injection timing in an inlet metering, opposed plunger rotary distributor pump engine?

A) low fuel load in pump chamber
B) high fuel load in pump chamber
C) high filter inlet restriction
D) sticking fuel shutoff solenoid
Question
Which name would be most closely associated with the invention of the inlet metering, opposed plunger rotary distributor pump?

A) Bosch
B) General Motors
C) Ford
D) Roosa
Question
What U.S. designed, diesel fuel injection pump outsold all other hydromechanical injection pumps manufactured world wide prior to the electronic age of diesel fuel management systems?

A) DPA
B) DB2
C) VE
D) M-100
Question
What moves the advance piston in electronically-managed versions of inlet metering, opposed plunger, rotary distributor injection pumps?

A) Fuel pressure
B) Spring force
C) Solenoid
D) Hall-effect sensor
Question
What controls the metering valve in an electronically controlled version of an inlet metering, opposed plunger, rotary distributor pump?

A) Engine rpm
B) ECM
C) Fuel pressure
D) Metered fuel quantity
Question
When an inlet metering, opposed plunger rotary distributor pump is adapted for management by computer, which of the following terms best describes the system?

A) full authority
B) partial authority
C) state of the art
D) high tech
Question
Technician A says that when an inlet metering, opposed plunger rotary distributor pump is ECM controlled, the inboard effective stroke of the plungers is electronically managed. Technician B says that on the same system, the advance piston position is electronically managed. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Identify the partial-authority control system used on inlet metering, opposed plunger, rotary distributor injection pumps that is sometimes found on agricultural and marine applications?

A) DPA-EPIC
B) PEEC
C) V-MAC
D) DDEC
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 23: Inlet-Metering Rotary Distributor Pumps
1
Technician A says that most hydromechanical rotary-distributor diesel injection pumps are used in indirect injection (IDI) applications. Technician B says that most hydromechanical rotary-distributor diesel injection pumps are used to fuel off-highway large bore engines. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Technician A only
2
What is the function of the delivery valve used on an inlet metering, opposed plunger, type of rotary distributor pump?

A) raises the nozzle opening pressure
B) retains residual line pressure
C) limits peak line pressure
D) prevents high pressure spikes
retains residual line pressure
3
What is used to lubricate the internal components of an inlet metering, opposed plunger, rotary injection pump during operation?

A) integral supply of engine oil
B) external supply of engine oil
C) sealed bearings
D) fuel from the vane pump
fuel from the vane pump
4
At what relative speed must an inlet metering, opposed plunger injection pump be driven when used to fuel a 4-stroke cycle diesel engine, with 6 engine cylinders?

A) half engine speed
B) engine speed
C) two times engine speed
D) six times engine speed
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
How many high pressure pumping chambers are used in a typical inlet metering, opposed plunger rotary distributor injection pump?

A) one
B) two
C) four
D) six
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
How many pumping plungers are used in the high pressure pump element used in an inlet metering, opposed plunger, rotary distributor pump used to fuel a six cylinder engine?

A) six
B) four
C) two
D) one
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Technician A says that an inlet metering, opposed plunger rotary distributor pump cannot be used to fuel an engine with more than six cylinders. Technician B says that a Stanadyne opposed plunger, rotary distributor pumps used to be popular on older Ford and GM diesel engines. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
An inlet metering, opposed plunger rotary distributor pump is used to fuel an automotive V-8 diesel engine. How many delivery valves are used?

A) one
B) two
C) four
D) eight
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Technician A says that the outward movement of the opposed plungers in an inlet metering, rotary distributor pump depends on centrifugal force and therefore, pump rotational speed. Technician B says that plunger outboard travel on the same pump is limited by leaf spring stops. Who is right?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
What force is used to move the advance piston in an inlet metering, opposed plunger rotary distributor pump that uses no computer controls?

A) spring force
B) centrifugal force
C) hydraulic force
D) mechanical force
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Which component(s) in an inlet metering, opposed plunger rotary distributor pump is moved by the advance piston?

A) opposed plungers
B) hydraulic head
C) metering valve
D) internal cam ring
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Which of the following best describes the operating principle of the vane type transfer pumps used on typical inlet metering, opposed plunger, rotary distributor pump?

A) centrifugal
B) constant velocity
C) variable cycle
D) positive displacement
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following would have the effect of advancing injection timing in an inlet metering, opposed plunger rotary distributor pump engine?

A) low fuel load in pump chamber
B) high fuel load in pump chamber
C) high filter inlet restriction
D) sticking fuel shutoff solenoid
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Which name would be most closely associated with the invention of the inlet metering, opposed plunger rotary distributor pump?

A) Bosch
B) General Motors
C) Ford
D) Roosa
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
What U.S. designed, diesel fuel injection pump outsold all other hydromechanical injection pumps manufactured world wide prior to the electronic age of diesel fuel management systems?

A) DPA
B) DB2
C) VE
D) M-100
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
What moves the advance piston in electronically-managed versions of inlet metering, opposed plunger, rotary distributor injection pumps?

A) Fuel pressure
B) Spring force
C) Solenoid
D) Hall-effect sensor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
What controls the metering valve in an electronically controlled version of an inlet metering, opposed plunger, rotary distributor pump?

A) Engine rpm
B) ECM
C) Fuel pressure
D) Metered fuel quantity
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
When an inlet metering, opposed plunger rotary distributor pump is adapted for management by computer, which of the following terms best describes the system?

A) full authority
B) partial authority
C) state of the art
D) high tech
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Technician A says that when an inlet metering, opposed plunger rotary distributor pump is ECM controlled, the inboard effective stroke of the plungers is electronically managed. Technician B says that on the same system, the advance piston position is electronically managed. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Identify the partial-authority control system used on inlet metering, opposed plunger, rotary distributor injection pumps that is sometimes found on agricultural and marine applications?

A) DPA-EPIC
B) PEEC
C) V-MAC
D) DDEC
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck