Deck 4: Electrical Protection and Safety: Part A
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
Play
Full screen (f)
Deck 4: Electrical Protection and Safety: Part A
1
Over voltage protection is recommended for
A)hydro-electric generators
B)steam turbine generators
C)gas turbine generators
D)all of the above
A)hydro-electric generators
B)steam turbine generators
C)gas turbine generators
D)all of the above
all of the above
2
Air blast circuit breakers for 400 kV power system are designed to operate in
A)100 microsecond
B)50 millisecond
C)0.5 sec
D)0.1 sec
A)100 microsecond
B)50 millisecond
C)0.5 sec
D)0.1 sec
50 millisecond
3
Overfluxing protection is recommended for
A)distribution transformer
B)generator transformer of the power plant
C)auto-transformer of the power plant
D)station transformer of the power plant
A)distribution transformer
B)generator transformer of the power plant
C)auto-transformer of the power plant
D)station transformer of the power plant
generator transformer of the power plant
4
Series capacitors are used to
A)compensate for line inductive reactance
B)compensate for line capacitive reactance
C)improve line voltage
D)none of the above
A)compensate for line inductive reactance
B)compensate for line capacitive reactance
C)improve line voltage
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
Admittance relay is _______ relay.
A)impedance
B)directional
C)non-directional
D)none of the above
A)impedance
B)directional
C)non-directional
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
The material used for fuse must have
A)low melting point and high specific resistance
B)low melting point and -low specific resistance
C)high melting point and low specific resistance
D)low melting point and any specific resistance
A)low melting point and high specific resistance
B)low melting point and -low specific resistance
C)high melting point and low specific resistance
D)low melting point and any specific resistance
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
If the fault occurs near the impedance relay, the VII ratio will be
A)constant for all distances
B)lower than that of if fault occurs away from the relay
C)higher than that of if fault occurs away from the relay
D)none of the above
A)constant for all distances
B)lower than that of if fault occurs away from the relay
C)higher than that of if fault occurs away from the relay
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
The torque produced in induction type relay (shaded pole structure) is
A)inversely proportional to the current
B)inversely proportional to the square of the current
C)proportional to the current
D)proportional to square of the current
A)inversely proportional to the current
B)inversely proportional to the square of the current
C)proportional to the current
D)proportional to square of the current
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
The steady state stability of the power system can be increased by
A)connecting lines in parallel
B)connecting lines in series
C)using machines of high impedance
D)reducing the excitation of machines
A)connecting lines in parallel
B)connecting lines in series
C)using machines of high impedance
D)reducing the excitation of machines
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
The inductive interference between power and communication line can be minimized by
A)transposition of the power line
B)transposition of the communication line
C)both (A) and (B)
D)increasing the distance between the conductors
A)transposition of the power line
B)transposition of the communication line
C)both (A) and (B)
D)increasing the distance between the conductors
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
The power loss is an important factor for the design of
A)transmission line
B)motor
C)generator
D)feeder
A)transmission line
B)motor
C)generator
D)feeder
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
A fuse is connected
A)in series with circuit
B)in parallel with circuit
C)either in series or in parallel with circuit
D)none of the above
A)in series with circuit
B)in parallel with circuit
C)either in series or in parallel with circuit
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
H.R.C. fuse, as compared to a rewirable fuse, has
A)no ageing effect
B)high speed of operation
C)high rupturing capacity
D)all of the above
A)no ageing effect
B)high speed of operation
C)high rupturing capacity
D)all of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
The fuse rating is expressed in terms of
A)current
B)voltage
C)VAR
D)kVA
A)current
B)voltage
C)VAR
D)kVA
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
The fuse blows off by
A)burning
B)arcing
C)melting
D)none of the above
A)burning
B)arcing
C)melting
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
On which of the following effects of electric current a fuse operates ?
A)Photoelectric effect
B)Electrostatic effect
C)Heating effect
D)Magnetic effect
A)Photoelectric effect
B)Electrostatic effect
C)Heating effect
D)Magnetic effect
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
An isolator is installed
A)to operate the relay of circuit breaker
B)as a substitute for circuit breaker
C)always independent of the position of circuit breaker
D)generally on both sides of a circuit breaker
A)to operate the relay of circuit breaker
B)as a substitute for circuit breaker
C)always independent of the position of circuit breaker
D)generally on both sides of a circuit breaker
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
A fuse in a motor circuit provides protection against
A)overload
B)short-circuit and overload
C)open circuit, short-circuit and overload
D)none of the above
A)overload
B)short-circuit and overload
C)open circuit, short-circuit and overload
D)none of the above
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Protection by fuses is generally not used beyond
A)20 A
B)50 A
C)100 A
D)200 A
A)20 A
B)50 A
C)100 A
D)200 A
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
A fuse is never inserted in
A)neutral wire
B)negative of D.C. circuit
C)positive of
D)C. circuit
A)neutral wire
B)negative of D.C. circuit
C)positive of
D)C. circuit
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Which of the following circuit breakers is used for the railway electrification?
A)Air blast circuit breaker
B)SF6 circuit breaker
C)Bulk oil circuit breaker
D)Minimum oil circuit breaker
A)Air blast circuit breaker
B)SF6 circuit breaker
C)Bulk oil circuit breaker
D)Minimum oil circuit breaker
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
The stability of arc in vacuum depends on _________.
A)The contact material only.
B)The circuit parameters only.
C)The contact materials and its vapour pressure.
D)Both (b) and (c)
A)The contact material only.
B)The circuit parameters only.
C)The contact materials and its vapour pressure.
D)Both (b) and (c)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
SF6 is which type of gas?
A)Electro positive
B)Electro negative
C)Both (a) and (b)
D)None of these
A)Electro positive
B)Electro negative
C)Both (a) and (b)
D)None of these
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
What is the average rate of rise of restriking voltage upto the first peak?
A)525 * 103kV / sec
B)453 * 103kV / sec
C)582 * 103 kV / sec
D)467 * 103 kV / sec
A)525 * 103kV / sec
B)453 * 103kV / sec
C)582 * 103 kV / sec
D)467 * 103 kV / sec
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Circuit breakers usually operate under
A)Steady short circuit current
B)Sub transient state of short circuit current
C)Transient state of short circuit current
D)None of these
A)Steady short circuit current
B)Sub transient state of short circuit current
C)Transient state of short circuit current
D)None of these
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck