Deck 8: Quality Control of Fluoroscopic Equipment
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
Play
Full screen (f)
Deck 8: Quality Control of Fluoroscopic Equipment
1
Which type of distortion that can occur with tube-type fluoroscopic image intensifiers is most often caused by the presence of strong magnetic fields?
A)Veiling glare
B)S distortion
C)Pincushion distortion
D)Vignetting
A)Veiling glare
B)S distortion
C)Pincushion distortion
D)Vignetting
B
2
At any combination of tube potential and current, fluoroscopic equipment with an automatic brightness control should not produce an entrance skin exposure exceeding ____ R/min.
A)2.5
B)5
C)10
D)20
A)2.5
B)5
C)10
D)20
C
3
The input phosphor of an image intensifier tube converts a(n) _____ image into a(n) _____ image.
A)x-ray; light
B)light; electron
C)electron; light
D)x-ray; electron
A)x-ray; light
B)light; electron
C)electron; light
D)x-ray; electron
A
4
A photocathode is a device that emits
A)light photons.
B)x-ray photons.
C)electrons.
D)all of the above.
A)light photons.
B)x-ray photons.
C)electrons.
D)all of the above.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Quality control tests of fluoroscopic systems should be performed
A)daily.
B)weekly.
C)semiannually.
D)annually.
A)daily.
B)weekly.
C)semiannually.
D)annually.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
Which type of test tool may be used to demonstrate pincushion distortion?
A)Dosimeter
B)Wire mesh tool
C)Ion chamber
D)Homogenous phantom
A)Dosimeter
B)Wire mesh tool
C)Ion chamber
D)Homogenous phantom
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
The television camera most commonly used to capture the fluoroscopic image from a tube type image intensifier is the:
A)image orthicon.
B)plumbicon.
C)vidicon.
D)charge-coupled device.
A)image orthicon.
B)plumbicon.
C)vidicon.
D)charge-coupled device.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
In standard broadcast television, one image frame consists of
A)one television field.
B)two television fields.
C)262.5 scan lines.
D)17 ms.
A)one television field.
B)two television fields.
C)262.5 scan lines.
D)17 ms.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Performance testing of fluoroscopic systems must include all the following except
A)x-ray tube housing.
B)automatic film processor.
C)total filtration.
D)automatic brightness control.
A)x-ray tube housing.
B)automatic film processor.
C)total filtration.
D)automatic brightness control.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
A reduction in brightness at the periphery of the image captured with an image intensifier tube is referred to as
A)pincushion distortion.
B)vignetting.
C)barrel distortion.
D)quantum mottle.
A)pincushion distortion.
B)vignetting.
C)barrel distortion.
D)quantum mottle.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck