Deck 11: Retrofit and Future Trends

Full screen (f)
exit full mode
Question
XH7 and XH9 desiccants are compatible with R-134a and R-12 refrigerants.
Use Space or
up arrow
down arrow
to flip the card.
Question
Technician A says mixing two different refrigerants in an air conditioning system is not considered contamination.Technician B says air in an air conditioning system will cause contamination.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Which of the following desiccants should be used with HFC-134a refrigerant?

A) XH5
B) XH7
C) XH9
D) b and c
Question
Which of the following desiccants should be used with HFC-134a refrigerant?

A) XH5
B) XH7
C) XH9
D) Both B and C
Question
R-12 with greater than 2 percent of R-134a is considered contaminated.
Question
Under the CAA,anyone performing repairs to a motor vehicle air conditioning system for pay must

A) be certified.
B)
B) use recovery/recycle equipment.
C) be a salaried employee of the shop.
D) a and
Question
Technician A says that the shop that performed the A/C system retrofit must be identified on the retrofit label.Technician B says that the new refrigerant installed must be identified on the retrofit label.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Technician A says mineral oil is compatible with R-12.Technician B says mineral oil is compatible with R-134a.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Three refrigerants are currently approved by the EPA for automotive use to replace R-12.
Question
R-744 is an acceptable substitute for both R-12 and R-134a in a refrigerant system retrofit.
Question
The air conditioning system is purged of refrigerant if the manifold gauges show a vacuum.
Question
The R-744 system can serve as a source of heat for the passenger compartment through the use of an integrated heat pump.
Question
R-744 systems require about half the refrigerant capacity of current R-134a systems.
Question
The retro fit label's background color for R-134a refrigerant is:

A) Tan
B) Royal Blue
C) Light Blue
D) White
Question
To drain oil from a component,the component must be removed from the vehicle.
Question
Technician A says changing any part of an original design changes the performance of the equipment.Technician B says if an extra fan and motor are added,a relay should also be added.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
A refrigerant retro fit label must contain all of the following,Except:

A) The refrigerant charge amount installed.
B) The amount of R-12 removed from the system.
C) The type of refrigerant oil installed and the part number.
D) Name and address of the installer who performed the retrofit.
Question
A purity test should be held any time there is a concern about the quality of the refrigerant in the system.
Question
All of the following statements about system evacuation are true,EXCEPT:

A) All systems should be evacuated for a minimum of 30 minutes.
B) Vacuum should reach at least 24 to 26 inHg (20.3 to 23.5 kPa absolute) in the first 15 minutes.
C) If vacuum does not reach 24 to 26 inHg (20.3 to 23.5 kPa absolute), evacuate for a longer time.
D) The longer the evacuation period, the better the moisture removal.
Question
A modification that updates or upgrades a system or device is called a retrofit.
Question
Technician A says flushing the air conditioning before retrofitting is a common procedure.Technician B says each component should be removed and flushed individually.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
When should an air conditioning system be evacuated?
Question
Under what conditions should system oil be charged directly into the compressor?
Question
What is the maximum capacity a recovery cylinder should be filled to at ambient temperatures.
Question
Vacuum measurement is being discussed.Technician A says the best method is to use an electronic thermistor vacuum gauge.Technician B says a thermistor may use an analog gauge to display vacuum readings.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
The concern in the world community has shifted from the threat of ozone-depleting chemicals to a concern over which of the following?

A) Global weather
B) Global disaster
C) Global cooling
D) Global warming
Question
What is the advantage of placing the vehicle in a draft-free work area?
Question
During the charging process of a FOT cycling-clutch system,how can you override the system so the compressor will stay engaged and not cycle?
Question
Under what conditions should hoses be replaced during a retrofit?
Question
Why is it important to affix decals to identify a new refrigerant type?
Question
During the retrofit process,when should service ports be changed from R-12 to R-134a access type?
Question
Retrofits are being discussed.Technician A says the procedure involves replacing the refrigerant.Technician B says new service fittings must be installed.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
The Clean Air Act of 1990 says after July 1,1992,which of the following refrigerants may be intentionally vented?

A) R-12
B) R-134a
C) R-22
D) None of the above
Question
What does it mean if after 5 minutes,the vacuum pump cannot pull a reasonable vacuum on the refrigerant system?
Question
Why should the technician rotate the clutch armature several revolutions by hand during charging?
Question
Technician A says the purity of refrigerants has been set by SAE purity standards for both R-12 and R-134a.Technician B says refrigerant should test at least 98 percent pure when tested with a purity tester.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
All of the following statements about thermostatic expansion vales on retrofitted systems are true,EXCEPT:

A) The expansion valve does not have to be replaced when retrofitting a system from R-12 to R-134a.
B) If a defective expansion valve is replaced, always use a model designed for the system refrigerant.
C) A R-12 expansion valve used in an R-134a system will result in higher superheat and reduced evaporator efficiency.
D) An R-134a valve used in a R-12 system will have reduced superheat.
Question
All of the following are removed when the air conditioner is evacuated,EXCEPT:

A) refrigerant.
B) oil.
C) moisture.
D) All of the above are removed.
Question
Evacuation of an air conditioning system is being discussed.Technician A says one factor affecting the speed of evacuation is internal restrictions.Technician B says all of the oil is usually removed during evacuation.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Technician A says after the retrofit is complete,a function test should be made.Technician B says system pressures and temperatures for HFC-134a should be the same as for CFC-12.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Discuss the use of conversion service fittings for conversions of R-12 to R-134a refrigerant.
Question
Give the general guidelines for determining whether a compressor should be replaced during retrofit.
Question
Why would a R-744 refrigerant system work well on a fuel cell-powered vehicle?
Question
When should a saddle clamp access valve be installed?
Question
What questions should the technician ask the customer if there is a possibility that the refrigerant is contaminated?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/45
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 11: Retrofit and Future Trends
1
XH7 and XH9 desiccants are compatible with R-134a and R-12 refrigerants.
True
2
Technician A says mixing two different refrigerants in an air conditioning system is not considered contamination.Technician B says air in an air conditioning system will cause contamination.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
B
3
Which of the following desiccants should be used with HFC-134a refrigerant?

A) XH5
B) XH7
C) XH9
D) b and c
D
4
Which of the following desiccants should be used with HFC-134a refrigerant?

A) XH5
B) XH7
C) XH9
D) Both B and C
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
5
R-12 with greater than 2 percent of R-134a is considered contaminated.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
6
Under the CAA,anyone performing repairs to a motor vehicle air conditioning system for pay must

A) be certified.
B)
B) use recovery/recycle equipment.
C) be a salaried employee of the shop.
D) a and
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
7
Technician A says that the shop that performed the A/C system retrofit must be identified on the retrofit label.Technician B says that the new refrigerant installed must be identified on the retrofit label.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
8
Technician A says mineral oil is compatible with R-12.Technician B says mineral oil is compatible with R-134a.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
9
Three refrigerants are currently approved by the EPA for automotive use to replace R-12.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
10
R-744 is an acceptable substitute for both R-12 and R-134a in a refrigerant system retrofit.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
11
The air conditioning system is purged of refrigerant if the manifold gauges show a vacuum.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
12
The R-744 system can serve as a source of heat for the passenger compartment through the use of an integrated heat pump.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
13
R-744 systems require about half the refrigerant capacity of current R-134a systems.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
14
The retro fit label's background color for R-134a refrigerant is:

A) Tan
B) Royal Blue
C) Light Blue
D) White
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
15
To drain oil from a component,the component must be removed from the vehicle.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
16
Technician A says changing any part of an original design changes the performance of the equipment.Technician B says if an extra fan and motor are added,a relay should also be added.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
17
A refrigerant retro fit label must contain all of the following,Except:

A) The refrigerant charge amount installed.
B) The amount of R-12 removed from the system.
C) The type of refrigerant oil installed and the part number.
D) Name and address of the installer who performed the retrofit.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
18
A purity test should be held any time there is a concern about the quality of the refrigerant in the system.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
19
All of the following statements about system evacuation are true,EXCEPT:

A) All systems should be evacuated for a minimum of 30 minutes.
B) Vacuum should reach at least 24 to 26 inHg (20.3 to 23.5 kPa absolute) in the first 15 minutes.
C) If vacuum does not reach 24 to 26 inHg (20.3 to 23.5 kPa absolute), evacuate for a longer time.
D) The longer the evacuation period, the better the moisture removal.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
20
A modification that updates or upgrades a system or device is called a retrofit.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
21
Technician A says flushing the air conditioning before retrofitting is a common procedure.Technician B says each component should be removed and flushed individually.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
22
When should an air conditioning system be evacuated?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
23
Under what conditions should system oil be charged directly into the compressor?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
24
What is the maximum capacity a recovery cylinder should be filled to at ambient temperatures.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
25
Vacuum measurement is being discussed.Technician A says the best method is to use an electronic thermistor vacuum gauge.Technician B says a thermistor may use an analog gauge to display vacuum readings.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
26
The concern in the world community has shifted from the threat of ozone-depleting chemicals to a concern over which of the following?

A) Global weather
B) Global disaster
C) Global cooling
D) Global warming
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
27
What is the advantage of placing the vehicle in a draft-free work area?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
28
During the charging process of a FOT cycling-clutch system,how can you override the system so the compressor will stay engaged and not cycle?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
29
Under what conditions should hoses be replaced during a retrofit?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
30
Why is it important to affix decals to identify a new refrigerant type?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
31
During the retrofit process,when should service ports be changed from R-12 to R-134a access type?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
32
Retrofits are being discussed.Technician A says the procedure involves replacing the refrigerant.Technician B says new service fittings must be installed.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
33
The Clean Air Act of 1990 says after July 1,1992,which of the following refrigerants may be intentionally vented?

A) R-12
B) R-134a
C) R-22
D) None of the above
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
34
What does it mean if after 5 minutes,the vacuum pump cannot pull a reasonable vacuum on the refrigerant system?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
35
Why should the technician rotate the clutch armature several revolutions by hand during charging?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
36
Technician A says the purity of refrigerants has been set by SAE purity standards for both R-12 and R-134a.Technician B says refrigerant should test at least 98 percent pure when tested with a purity tester.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
37
All of the following statements about thermostatic expansion vales on retrofitted systems are true,EXCEPT:

A) The expansion valve does not have to be replaced when retrofitting a system from R-12 to R-134a.
B) If a defective expansion valve is replaced, always use a model designed for the system refrigerant.
C) A R-12 expansion valve used in an R-134a system will result in higher superheat and reduced evaporator efficiency.
D) An R-134a valve used in a R-12 system will have reduced superheat.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
38
All of the following are removed when the air conditioner is evacuated,EXCEPT:

A) refrigerant.
B) oil.
C) moisture.
D) All of the above are removed.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
39
Evacuation of an air conditioning system is being discussed.Technician A says one factor affecting the speed of evacuation is internal restrictions.Technician B says all of the oil is usually removed during evacuation.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
40
Technician A says after the retrofit is complete,a function test should be made.Technician B says system pressures and temperatures for HFC-134a should be the same as for CFC-12.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
41
Discuss the use of conversion service fittings for conversions of R-12 to R-134a refrigerant.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
42
Give the general guidelines for determining whether a compressor should be replaced during retrofit.
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
43
Why would a R-744 refrigerant system work well on a fuel cell-powered vehicle?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
44
When should a saddle clamp access valve be installed?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
45
What questions should the technician ask the customer if there is a possibility that the refrigerant is contaminated?
Unlock Deck
Unlock for access to all 45 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 45 flashcards in this deck.