Deck 13: Automated Procedures

Full screen (f)
exit full mode
Question
Which of the following is a correct statement regarding measurements of turbidity?

A) Light is scattered at a determined angle.
B) It is unaffected by large particles precipitating out of a solution.
C) The reference value is recorded in units of relative light scatter.
D) It represents the scattered light in forward direction.
Use Space or
up arrow
down arrow
to flip the card.
Question
A fluorescent polarization immunoassay can perform a(n):

A) microparticle enzyme immunoassay.
B) fluorescence polarization immunoassay.
C) ion capture technologies.
D) all of the above.
Question
Latex particles act as ______________________ in nephelometry.

A) antigen-coated reaction intensifiers
B) antigen-coated reaction stabilizers of precipitate
C) sensitivity enhancers
D) color reaction intensifiers
Question
A blood specimen for testing for the presence of cryoglobulins should be:

A) immediately placed in warm water after collection.
B) immediately placed on ice after collection.
C) immediately refrigerated at 4° C.
D) not treated in any special way.
Question
A fundamental prerequisite for nephelometric protein quantitation is the:

A) dissolution of large protein molecules.
B) formation of a macromolecular complex.
C) pH of the solution.
D) ionic strength of the solution.
Question
The principle of flow cytometry is based on:

A) antigen-antibody reactions.
B) the formation of immune complexes.
C) the reaction of dyes with the cellular component of interest.
D) the reaction of dyes with immune complexes.
Question
Immunophenotyping includes the detection or identification of:

A) CD34+ stem cells.
B) minimal residual disease in patients with leukemia.
C) T and B lymphocytes.
D) all of the above.
Question
Nephelometry is less expensive initially than other forms of testing.
Question
In nephelometry measurement,if antigen overwhelms the quantity of antibody,the measured signal:

A) increases.
B) decreases.
C) remains the same.
D) fluctuates between high and low.
Question
In nephelometry measurement,a __________________method is used.

A) variable-time
B) fixed-time
C) fluorescent-tagging
D) competitive immunoassay
Question
Laser is an acronym for:

A) light amplification by stimulated emission of radiation.
B) light augmentation by stimulated emitted radiation.
C) light amplified by stimulated energy radiation.
D) large angle stimulation by emitted radiation.
Question
Monoclonal cryoglobulins are most often:

A) IgM.
B) IgG.
C) IgA.
D) either a or b
Question
Cryoglobulins are proteins that precipitate or gel when cooled to:

A) -18° C.
B) 0° C.
C) 4° C.
D) 18° C.
Question
A photon is a:

A) basic unit of light.
B) basic unit of all radiation.
C) component of an atom.
D) component of laser light.
Question
The major application(s)of flow cell technology is (are):

A) identification of cells.
B) cell sorting before further analysis.
C) diagnosis of autoimmune disease.
D) both a and b
Question
Cryoglobulin analysis can be useful in the diagnosis of:

A) hypothermia.
B) Raynaud's phenomenon.
C) infectious hepatitis.
D) rheumatoid arthritis.
Question
Current fluorescent methods can perform up to _______-color analysis.

A) two
B) four
C) eight
D) 16
Question
A fluorochrome is a(n):

A) dye.
B) immunologic reagent.
C) nonspecific indicator.
D) both a and b
Question
The most frequently used fluorochrome(s)is (are):

A) fluorescein isothiocyanate (FITC).
B) phycoerythrin (PE).
C) peridinin chlorophyll protein (PerCP).
D) all of the above.
Question
Nephelometry can be used to assay all the following except:

A) IgM.
B) IgG.
C) IgD.
D) IgA.
Question
The most common type of laser light used in laboratory instrumentation is neon.
Question
Microbial contamination can produce erroneous results in nephelometry.
Question
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Documentation of quality control data

A)Preanalytical
B)Analytical
C)Postanalytical
Question
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Specimen labeling

A)Preanalytical
B)Analytical
C)Postanalytical
Question
Monoclonal antibodies can produce spurious results in nephelometry.
Question
Laser light is concentrated.
Question
Lasers sort the energy in atoms and molecules,concentrate it,and release it in powerful waves.
Question
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Validation of results

A)Preanalytical
B)Analytical
C)Postanalytical
Question
Laser light is multicolored.
Question
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Quality control

A)Preanalytical
B)Analytical
C)Postanalytical
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/30
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Automated Procedures
1
Which of the following is a correct statement regarding measurements of turbidity?

A) Light is scattered at a determined angle.
B) It is unaffected by large particles precipitating out of a solution.
C) The reference value is recorded in units of relative light scatter.
D) It represents the scattered light in forward direction.
Light is scattered at a determined angle.
2
A fluorescent polarization immunoassay can perform a(n):

A) microparticle enzyme immunoassay.
B) fluorescence polarization immunoassay.
C) ion capture technologies.
D) all of the above.
all of the above.
3
Latex particles act as ______________________ in nephelometry.

A) antigen-coated reaction intensifiers
B) antigen-coated reaction stabilizers of precipitate
C) sensitivity enhancers
D) color reaction intensifiers
antigen-coated reaction intensifiers
4
A blood specimen for testing for the presence of cryoglobulins should be:

A) immediately placed in warm water after collection.
B) immediately placed on ice after collection.
C) immediately refrigerated at 4° C.
D) not treated in any special way.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
5
A fundamental prerequisite for nephelometric protein quantitation is the:

A) dissolution of large protein molecules.
B) formation of a macromolecular complex.
C) pH of the solution.
D) ionic strength of the solution.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
6
The principle of flow cytometry is based on:

A) antigen-antibody reactions.
B) the formation of immune complexes.
C) the reaction of dyes with the cellular component of interest.
D) the reaction of dyes with immune complexes.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
7
Immunophenotyping includes the detection or identification of:

A) CD34+ stem cells.
B) minimal residual disease in patients with leukemia.
C) T and B lymphocytes.
D) all of the above.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
8
Nephelometry is less expensive initially than other forms of testing.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
9
In nephelometry measurement,if antigen overwhelms the quantity of antibody,the measured signal:

A) increases.
B) decreases.
C) remains the same.
D) fluctuates between high and low.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
10
In nephelometry measurement,a __________________method is used.

A) variable-time
B) fixed-time
C) fluorescent-tagging
D) competitive immunoassay
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
11
Laser is an acronym for:

A) light amplification by stimulated emission of radiation.
B) light augmentation by stimulated emitted radiation.
C) light amplified by stimulated energy radiation.
D) large angle stimulation by emitted radiation.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
12
Monoclonal cryoglobulins are most often:

A) IgM.
B) IgG.
C) IgA.
D) either a or b
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
13
Cryoglobulins are proteins that precipitate or gel when cooled to:

A) -18° C.
B) 0° C.
C) 4° C.
D) 18° C.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
14
A photon is a:

A) basic unit of light.
B) basic unit of all radiation.
C) component of an atom.
D) component of laser light.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
15
The major application(s)of flow cell technology is (are):

A) identification of cells.
B) cell sorting before further analysis.
C) diagnosis of autoimmune disease.
D) both a and b
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
16
Cryoglobulin analysis can be useful in the diagnosis of:

A) hypothermia.
B) Raynaud's phenomenon.
C) infectious hepatitis.
D) rheumatoid arthritis.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
17
Current fluorescent methods can perform up to _______-color analysis.

A) two
B) four
C) eight
D) 16
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
18
A fluorochrome is a(n):

A) dye.
B) immunologic reagent.
C) nonspecific indicator.
D) both a and b
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
19
The most frequently used fluorochrome(s)is (are):

A) fluorescein isothiocyanate (FITC).
B) phycoerythrin (PE).
C) peridinin chlorophyll protein (PerCP).
D) all of the above.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
20
Nephelometry can be used to assay all the following except:

A) IgM.
B) IgG.
C) IgD.
D) IgA.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
21
The most common type of laser light used in laboratory instrumentation is neon.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
22
Microbial contamination can produce erroneous results in nephelometry.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
23
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Documentation of quality control data

A)Preanalytical
B)Analytical
C)Postanalytical
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
24
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Specimen labeling

A)Preanalytical
B)Analytical
C)Postanalytical
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
25
Monoclonal antibodies can produce spurious results in nephelometry.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
26
Laser light is concentrated.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
27
Lasers sort the energy in atoms and molecules,concentrate it,and release it in powerful waves.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
28
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Validation of results

A)Preanalytical
B)Analytical
C)Postanalytical
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
29
Laser light is multicolored.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
30
MATCHING
Match the activity with the appropriate phase of testing related to laboratory automation.

Quality control

A)Preanalytical
B)Analytical
C)Postanalytical
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 30 flashcards in this deck.