If a technique chart is being used, and the IR is overexposed, the radiographer should assume the chart is inaccurate and come up with his or her own exposure factors.
(True/False)
4.8/5
(27)
What describes the shortest exposure time required for the AEC device to operate?
(Multiple Choice)
4.9/5
(37)
Where is the sensor located in an automatic exposure device that converts light into an electrical signal?
(Multiple Choice)
4.8/5
(42)
Two identical rooms having the same generator and tube and installed at the same time do not require development of separate technique charts.The chart for one room can accurately be used in the other.
(True/False)
4.7/5
(29)
When doing a CR study using AEC, what will happen to the patient exposure when changing from the -1 to +1 density setting?
(Multiple Choice)
4.8/5
(36)
Exposure time will ______ using AEC when patient thickness decreases.
(Multiple Choice)
4.7/5
(38)
With a CR system, when using AEC to image a patient who is having difficulty holding still, increasing the mA (if the unit allows)will:
(Multiple Choice)
4.9/5
(39)
If a part measures 14 cm and requires the use of 75 kVp, how much kVp would a part measuring 18 cm require when using a variable kVp-fixed mAs technique chart?
(Multiple Choice)
4.9/5
(38)
With AEC it is easy to use multiple types of image receptors, because the detectors can sense image receptor type and make appropriate adjustments.
(True/False)
4.8/5
(43)
When exposure factors are selected using APR, the variables should not be adjusted.
(True/False)
4.8/5
(36)
When using film-screen, what happens when an outside detector is selected for an AP thoracic spine?
(Multiple Choice)
5.0/5
(41)
AEC eliminates the need for the radiographer to select the actual _____ the examination will require.
(Multiple Choice)
4.9/5
(30)
The technique chart will provide information as to how to recognize and compensate for additive pathology.
(True/False)
4.8/5
(42)
Where is the sensor located in an automatic exposure device with a gas-filled chamber?
(Multiple Choice)
4.7/5
(40)
With modern x-ray equipment, the AEC system's minimum response time is typically:
(Multiple Choice)
4.9/5
(34)
When using AEC, what should the radiographer adjust to manipulate the contrast of the image?
(Multiple Choice)
4.8/5
(32)