The property of the x-ray beam that impacts the unsharpness on the radiograph is beam:
(Multiple Choice)
4.8/5
(36)
Film-screen images should be produced with very high kVp and very low mAs in order to reduce patient exposure.
(True/False)
4.7/5
(35)
In order to see the effect of changing kVp, a greater change is needed when operating at low kVp as compared to high kVp.
(True/False)
4.8/5
(35)
Which one of the following immobilizing devices requires an increase in the exposure technique?
(Multiple Choice)
4.8/5
(31)
Which of the following contrast media do not require an adjustment in exposure factors?
(Multiple Choice)
4.9/5
(35)
With all other factors remaining the same, a patient with which body habitus would require the highest exposure factors?
(Multiple Choice)
5.0/5
(45)
Knowing that 6 mAs is appropriate for a knee examination done at 40" SID, how much mAs should be used at 56" SID?
(Multiple Choice)
4.8/5
(40)
Which of the following mA and exposure time combinations does not produce 12 mAs?
(Multiple Choice)
4.9/5
(40)
With film-screen imaging, for a given exposure technique, increasing part thickness decreases radiographic density.
(True/False)
4.9/5
(37)
When choosing a grid for an examination, the grid with the highest grid ratio should always be selected in order to most improve image contrast.
(True/False)
5.0/5
(43)
Using a small focal spot size may be prohibited due to the:
(Multiple Choice)
5.0/5
(37)
The digital imaging exposure indicator reflects the amount of radiation:
(Multiple Choice)
4.8/5
(40)
If the first radiograph of a chest is done using 72 inches and 12 mAs, and a second radiograph is done using 40 inches, how much mAs should be used to maintain exposure to the IR?
(Multiple Choice)
4.9/5
(34)
When a film-screen image needs to be repeated because it is too dark, the minimum change in mAs needed is:
(Multiple Choice)
4.8/5
(36)
Generally speaking, what do additive pathologic conditions require?
(Multiple Choice)
4.9/5
(37)
With film-screen imaging, which of the following technique factors will produce an image with the greatest density?
(Multiple Choice)
4.7/5
(35)
With film-screen imaging, what is the primary controller of image contrast?
(Multiple Choice)
4.8/5
(45)
When the SID is divided by the SOD, what is the result called?
(Multiple Choice)
4.8/5
(42)