Exam 6: Iterative Reconstruction Basics

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Statistical methods without modeling use photon counting statistics during the reconstruction process.

Free
(True/False)
5.0/5
(31)
Correct Answer:
Verified

False

The physics model considers the radiation attenuation interactions that occur within the patient.

Free
(True/False)
4.8/5
(42)
Correct Answer:
Verified

False

The first IR was used by Professor Allan Cormack.

Free
(True/False)
4.7/5
(44)
Correct Answer:
Verified

False

Limitations presented by the filtered back-projection (FBP) algorithm include each of the following except:

(Multiple Choice)
4.9/5
(39)

The term iterative refers to the characteristics of the CT imaging system and the imaged object.

(True/False)
4.7/5
(38)

FBP algorithms assume that all X-ray photon interactions take place across the full area of the detector array.

(True/False)
4.9/5
(37)

The IR loop is responsible for producing raw data and subjecting it to the standard FBP algorithm.

(True/False)
4.8/5
(32)

In a 2015 performance evaluation, it was noted that the reduced dose Iterative Model Reconstruction (RD IMR) algorithm proved significantly better than reduced FBP (RD FBP) algorithm in each of these pathologically processes except:

(Multiple Choice)
4.9/5
(26)

The IR loop process is complete once a predefined quality criterion in the image estimate is fulfilled.

(True/False)
4.9/5
(28)

The first IR commercially available in CT scanners was the Image Reconstruction Image Space in 2009.

(True/False)
4.8/5
(33)

Please match each of the following IR algorithms to the vendor who introduced it. Answer selections will be used only once. -ASIR-V

(Multiple Choice)
4.9/5
(37)

The criteria used to evaluate IR's performance in various studies include each of the following except:

(Multiple Choice)
4.9/5
(34)

Please match each of the following IR algorithms to the vendor who introduced it. Answer selections will be used only once. -SAFIRE

(Multiple Choice)
4.9/5
(32)

What step in the typical IR process generates the initial CT image from an FBP algorithm?

(Multiple Choice)
4.9/5
(31)

Which model addresses the X-ray source, image voxel, and detectors?

(Multiple Choice)
4.8/5
(32)

Which of the following is not a primary goal of iterative reconstruction (IR) algorithms?

(Multiple Choice)
4.9/5
(40)

As documented by a 2012 performance evaluation, what percentage of dose reduction did the ASIR algorithm result in when compared to the FBP algorithm for a CT chest exam?

(Multiple Choice)
4.7/5
(33)

Model-based IR methods attempt to model the acquisition process in hopes that the artificial image matches the acquired raw data.

(True/False)
4.7/5
(36)

Please match each of the following IR algorithms to the vendor who introduced it. Answer selections will be used only once. -iDose

(Multiple Choice)
4.9/5
(38)

What term is known as a calculation process using a series of operations that are repeated several times?

(Multiple Choice)
4.9/5
(34)