Exam 10: PLC Installation Practices, Editing, and Troubleshooting

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

The data monitor feature of a PLC may allow you to:

Free
(Multiple Choice)
4.8/5
(26)
Correct Answer:
Verified

D

I/O module leakage current is caused by bleeder resistors.

Free
(True/False)
4.9/5
(42)
Correct Answer:
Verified

False

With reference to the condition illustrated, what is the most likely fault? With reference to the condition illustrated, what is the most likely fault?

Free
(Multiple Choice)
4.8/5
(30)
Correct Answer:
Verified

A

Using PLC editing functions, instructions and rungs can be added, deleted, or modified.

(True/False)
4.7/5
(34)

Preparing a PLC control process for start-up is called:

(Multiple Choice)
4.8/5
(33)

One of the diagnostic checks carried out by the processor is the proper operation of all I/O devices.

(True/False)
4.9/5
(35)

The procedure of pre-start-up inspection is commonly referred to as field checkout, or commissioning.

(True/False)
4.8/5
(41)

The input wiring or device is suspected as being the source of a PLC problem. If this circuit is not at fault, then the status indicator on the input module should be illuminated when the input device is:

(Multiple Choice)
4.9/5
(37)

A watchdog timer is used to monitor:

(Multiple Choice)
4.8/5
(31)

The status indicator on an input module will normally be illuminated if the input device is off and examined for an off condition.

(True/False)
4.8/5
(30)

Malfunctions due to electrical noise interference usually cause:

(Multiple Choice)
4.8/5
(36)

Typically, PLC systems installed inside an enclosure can withstand a maximum of:

(Multiple Choice)
4.8/5
(27)

Preparing a PLC control process for initial start-up is known as commissioning.

(True/False)
5.0/5
(43)

A hardwired electromechanical master control relay is not normally included as part of the wiring for a PLC system.

(True/False)
4.9/5
(40)

Excessive line voltage variations to a PLC installation can be corrected by installing a:

(Multiple Choice)
4.9/5
(34)

PLC output modules may incorporate fuse or electronic protection for output circuitry.

(True/False)
4.8/5
(36)

Ground loop circuits cause problems by adding or subtracting current or voltage from input signal sources.

(True/False)
4.9/5
(46)

An addressing conflict is caused by the same address being used for two or more coil instructions in the same program.

(True/False)
4.8/5
(39)

A diode can be connected in reverse-bias across a DC solenoid to suppress voltage spikes.

(True/False)
4.9/5
(42)

With reference to the troubleshooting guide, which condition indicates no fault? With reference to the troubleshooting guide, which condition indicates no fault?

(Multiple Choice)
4.8/5
(38)
Showing 1 - 20 of 99