Exam 12: Transmission Lines
Exam 1: Introductory Topics32 Questions
Exam 2: Amplitude Modulation: Transmission23 Questions
Exam 3: Amplitude Modulation: Reception32 Questions
Exam 4: Single-Sideband Communications34 Questions
Exam 5: Frequency Modulation: Transmission52 Questions
Exam 6: Frequency Modulation: Reception27 Questions
Exam 7: Communications Techniques16 Questions
Exam 8: Digital Communications: Coding Techniques26 Questions
Exam 9: Wired Digital Communications19 Questions
Exam 10: Wireless Digital Communications25 Questions
Exam 11: Network Communications40 Questions
Exam 12: Transmission Lines40 Questions
Exam 13: Wave Propagation25 Questions
Exam 14: Antennas18 Questions
Exam 15: Waveguides and Radar21 Questions
Exam 16: Microwaves and Lasers18 Questions
Exam 17: Television40 Questions
Exam 18: Fiber Optics33 Questions
Select questions type
The input impedance of a half-wavelength section of 50 ohm transmission line that is terminated with an open is:
Free
(Multiple Choice)
4.8/5
(35)
Correct Answer:
C
A transmission line terminated with an open has a reflection coefficient at the load of:
Free
(Multiple Choice)
4.8/5
(37)
Correct Answer:
C
A commonly used coaxial cable, RG-58, has a characteristic impedance of 50 ohms. If the spacing between the conductors is doubled, its characteristic impedance will:
Free
(Multiple Choice)
4.8/5
(37)
Correct Answer:
C
What makes conductors behave differently at high frequencies than they do at low frequencies?
(Multiple Choice)
4.8/5
(29)
The disadvantage of not having a perfectly matched transmission line in a communication system is:
(Multiple Choice)
4.8/5
(31)
Which of the following is not an application of a transmission line?
(Multiple Choice)
4.9/5
(35)
A pulse-technique used in determining the location of a fault in a transmission line is called:
(Multiple Choice)
4.7/5
(39)
A non-lossy transmission line terminated with a short circuit will have:
(Multiple Choice)
5.0/5
(26)
Which of the following can be determined using a slotted line method?
(Multiple Choice)
4.9/5
(35)
A quarter-wavelength transmission line is terminated with a 300 ohm load. Its input impedance is 75 ohms. Its characteristic impedance is:
(Multiple Choice)
5.0/5
(30)
Moving a full revolution around an SWR circle on the Smith chart represents:
(Multiple Choice)
4.8/5
(37)
A transmission line that is terminated with a resistive load that is equal to the characteristic impedance of the line is called:
(Multiple Choice)
4.8/5
(32)
Wiring of the RJ-45 connector CAT6 cable is defined by the telecommunications industry standard:
(Multiple Choice)
4.9/5
(31)
Showing 1 - 20 of 40
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)