Exam 14: Three-Phase Transformers
Exam 1: Atomic Structure20 Questions
Exam 2: Electrical Quantities, Ohms Law, and Resistors20 Questions
Exam 3: Electrical Sources and Static Charges20 Questions
Exam 4: Magnetism20 Questions
Exam 5: Series Circuits20 Questions
Exam 6: Parallel Circuits20 Questions
Exam 7: Combination Circuits20 Questions
Exam 8: Measuring Instruments20 Questions
Exam 9: Alternating Current20 Questions
Exam 10: Alternating Current Loads19 Questions
Exam 11: Capacitive Loads20 Questions
Exam 12: Three-Phase Circuits20 Questions
Exam 13: Transformers20 Questions
Exam 14: Three-Phase Transformers20 Questions
Exam 15: Electrical Services20 Questions
Exam 16: General Wiring Practices Part 1: Receptacle and Switch Connections20 Questions
Exam 17: General Wiring Practices Part 2: Protection Circuits, Dimmers, and Chimes20 Questions
Exam 18: Three-Phase Motors20 Questions
Exam 19: Single-Phase Motors20 Questions
Exam 20: Schematics and Wiring Diagrams20 Questions
Exam 21: Motor Installation20 Questions
Select questions type
Checking a delta connection for proper connection is called ____.
Free
(Multiple Choice)
4.7/5
(36)
Correct Answer:
D
Which of the following is a three-phase transformer connection requiring only two transformers?
Free
(Multiple Choice)
4.8/5
(30)
Correct Answer:
B
When all three lines of a delta-wye connection are carrying the same amount of amperage, what is the neutral current value?
Free
(Multiple Choice)
4.9/5
(45)
Correct Answer:
A
Which of the following would most likely be used to show the power distribution system of a large industrial plant?
(Multiple Choice)
4.8/5
(38)
Three-phase transformer connections are often used to supply single-phase loads, which tend to unbalance the system.
(True/False)
4.8/5
(37)
Which term is used for the voltage measured from the center tap of one transformer in a delta connection to the junction of the transformer(s) that are not center tapped?
(Multiple Choice)
4.8/5
(36)
A three-phase load that has unequal current flow through the phases is said to be ____.
(Multiple Choice)
4.8/5
(31)
Which of the following is a three-phase connection formed by connecting the start end of a phase winding to the finish end of another?
(Multiple Choice)
4.9/5
(44)
The amount of magnetic flux produced by one object that influences another is called magnetic ____.
(Multiple Choice)
4.8/5
(31)
If power is applied to the transformer bank before the delta connection is closed, the voltmeter should indicate ____ volts.
(Multiple Choice)
5.0/5
(39)
Delta connections should be checked for proper polarity after applying power.
(True/False)
4.8/5
(37)
Which of the following is a three-phase connection formed by connecting one end of each phase together to form a center point?
(Multiple Choice)
4.9/5
(35)
A tap in the center of a transformer winding that will provide one half of the rated voltage of the winding is called a ____ tap.
(Multiple Choice)
4.8/5
(44)
If the output voltage of a delta secondary is 240 volts, and one winding of the delta connection has been reversed, the voltmeter will indicate a voltage of ____.
(Multiple Choice)
4.9/5
(33)
A true three-phase transformer contains six separate transformers wound on a single core.
(True/False)
4.9/5
(34)
Single-phase transformers connected in three-phase configurations are called three-phase transformer ____.
(Multiple Choice)
4.9/5
(40)
As a general rule, three-phase transformers will have one side connected as a ____.
(Multiple Choice)
4.8/5
(39)
The disadvantage for three-phase transformers is that if a single transformer should fail, the entire transformer must be repaired or replaced.
(True/False)
4.8/5
(35)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)