Exam 29: Three-Phase Transformers

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

A wye-delta transformer has a primary voltage of 7200 V and a secondary voltage of 360 V. What is the turns ratio?

Free
(Multiple Choice)
4.7/5
(36)
Correct Answer:
Verified

D

A delta-wye transformer has its _____ connected as a delta and its _____ connected as a wye.

Free
(Multiple Choice)
4.9/5
(34)
Correct Answer:
Verified

B

When using an open delta with a center tapped transformer, one wire is the high leg. The high leg is the one that _____.

Free
(Multiple Choice)
4.9/5
(35)
Correct Answer:
Verified

A

A wye-delta transformer has a primary line voltage of 7200 V and a secondary line voltage of 480 V. What is the turns ratio?

(Multiple Choice)
4.9/5
(42)

In an open delta with a center-tapped transformer, label the two ends of the center-tapped transformer as L2 and L3 and label the high leg as L1. The current flow in the neutral (center tap) is equal to _____.

(Multiple Choice)
4.8/5
(36)

In three-phase transformer connections, the primary leads are labeled with the letter _____ and the secondary leads are labeled with the letter _____.

(Multiple Choice)
4.9/5
(38)

The main power distribution system of a large industrial plant  is generally shown using a(n) _____ diagram.

(Multiple Choice)
4.8/5
(38)

A wye-delta transformer has its _____ connected as a wye and its _____ connected as a delta.

(Multiple Choice)
4.8/5
(42)

An open delta connection is made using _____ single-phase transformers.

(Multiple Choice)
5.0/5
(38)

When single-phase loads are tied to a three-phase transformer, the phase currents of the transformer will be automatically balanced.

(True/False)
4.9/5
(31)

A delta-delta transformer has a primary voltage of 7200 V and a secondary voltage of 360 V. What is the turns ratio?

(Multiple Choice)
4.7/5
(37)

A wye-delta transformer has a turns ratio of 2:1. It has a secondary line voltage of 480 V. The secondary is connected to a wye-connected three-phase resistive load of 50 Ω in each phase. What is the primary phase current?

(Multiple Choice)
4.9/5
(38)

For installations that will have both three-phase and single phase loads on a three-phase transformer, the utility company often provides a(n) _____ three-phase transformer.

(Multiple Choice)
4.8/5
(40)

When connecting three transformers for three-phase use with a delta secondary, a voltage test should be done before closing the secondary. The correct voltage reading is _____.

(Multiple Choice)
4.7/5
(32)

A wye-delta transformer has a turns ratio of 2:1. It has a secondary line voltage of 480 V. The secondary is connected to a wye-connected three-phase resistive load of 50 Ω in each phase. What is the primary line current?

(Multiple Choice)
4.9/5
(42)

A wye-delta transformer has a secondary phase voltage of 480 V. A delta-connected resistive load has a resistance of 12 Ω in each leg. What is the current in each load leg?

(Multiple Choice)
4.9/5
(38)

A delta-wye transformer has a turns ratio of 9:1. The primary line voltage is 3600 V. What is the secondary line voltage?

(Multiple Choice)
4.9/5
(35)

A wye-delta transformer has a turns ratio of 2:1. It has a secondary line voltage of 480 V. The secondary is connected to a wye-connected three-phase resistive load of 50 Ω in each phase. What is the secondary phase current?

(Multiple Choice)
4.9/5
(35)

In an open delta with single-phase loads, the high leg must be identified by _____.

(Multiple Choice)
4.9/5
(44)

What function is performed by dielectric oil?

(Multiple Choice)
4.9/5
(39)
Showing 1 - 20 of 25
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)